<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:slash="http://purl.org/rss/1.0/modules/slash/">
  <channel>
    <title>Shinjo(shinjopump)</title>
    <description>Industrial Pump Supplier in China Offers All Kinds of Industrial Pumps with ISO, API, ANSI &amp; JIS Standards, in Stainless Steel, Hastelloy, Cast Iron, etc.</description>
    <pubDate>Sun, 25 Oct 2026 10:50:01 +0000</pubDate>
    <generator>Laminas_Feed_Writer 2 (https://getlaminas.org)</generator>
    <link>https://www.shinjopump.com/</link>
    <author>sales@shinjopump.com (Shinjo)</author>
    <dc:creator>Shinjo</dc:creator>
    <atom:link rel="self" type="application/rss+xml" href="https://www.shinjopump.com/rss.xml"/>
    <atom:link rel="hub" href="https://pubsubhubhub.appspot.com/"/>
    <item>
      <title>Centrifugal Pump Maintenance: Wear Limits &amp; Clearances</title>
      <description><![CDATA[Centrifugal pump maintenance that extends pump life: routine checklist, wet-end wear limits, impeller and wear ring clearances, plus a rebuild video.]]></description>
      <pubDate>Sun, 18 Oct 2026 17:43:26 +0000</pubDate>
      <link>https://www.shinjopump.com/news/centrifugal-pump-maintenance.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/centrifugal-pump-maintenance.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content"><div class="sj-article">
<p class="sj-lead">Centrifugal pump maintenance that really extends pump life comes down to two habits: routine checks while the pump runs, and a precision rebuild when it is opened. In a rebuild, the wet end decides the result. New bearings and a new seal will not last if the impeller, casing and stuffing box cover go back with worn faces and open clearances. This guide follows Crane Engineering's precision maintenance video and adds the routine checks, wear limits and fits you need to bring a pump back to as-new condition.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="video-precision-maintenance-of-a-centrifugal-pump--0">Video: Precision Maintenance of a Centrifugal Pump</h2><a class="header-anchor" href="#video-precision-maintenance-of-a-centrifugal-pump--0" title="Video: Precision Maintenance of a Centrifugal Pump" aria-label="Video: Precision Maintenance of a Centrifugal Pump"></a></div>

<div class="sj-video"><iframe allow="accelerometer; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen="" loading="lazy" referrerpolicy="strict-origin-when-cross-origin" src="https://www.youtube.com/embed/SYVYoHlb9d4" title="Precision Maintenance - Overview (Crane Engineering)" data-src="https://www.youtube.com/embed/SYVYoHlb9d4" class="lazyload" style="max-width:100%;margin:0 auto;"></iframe></div>

<p class="sj-video-cap">Joe Frank of Crane Engineering inspects the wet end of a back pull-out end-suction pump. Video: <a href="https://www.youtube.com/watch?v=SYVYoHlb9d4" rel="noopener" target="_blank">Crane Engineering on YouTube</a> (10:20).</p>

<p>What the video covers:</p>

<ul>
	<li><strong>0:42</strong> Casing inspection: face grooves, gasket area and cutwater</li>
	<li><strong>1:32</strong> Impeller inspection: vanes, back pump-out vanes and fits</li>
	<li><strong>2:07</strong> Stuffing box cover inspection</li>
	<li><strong>3:00</strong> Wear limits for reusing each part</li>
	<li><strong>4:22</strong> Impeller clearance, thrust and seal life</li>
	<li><strong>6:43</strong> Worn parts from real pumps</li>
	<li><strong>8:32</strong> An abrasive wear example</li>
	<li><strong>9:22</strong> Wear rings on split-case pumps</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="routine-centrifugal-pump-maintenance-checklist--1">Routine Centrifugal Pump Maintenance Checklist</h2><a class="header-anchor" href="#routine-centrifugal-pump-maintenance-checklist--1" title="Routine Centrifugal Pump Maintenance Checklist" aria-label="Routine Centrifugal Pump Maintenance Checklist"></a></div>

<p>Most pump failures give warning first: noise, heat, leakage or vibration. Routine centrifugal pump maintenance catches them while the fix is still cheap. The schedule below draws on a widely used preventive maintenance guide for centrifugal pumps and on the U.S. Department of Energy's pumping system tip sheets. Adapt the intervals to your duty, and follow your pump manual where it differs.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Interval</th>
			<th>Check</th>
			<th>What to look for</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Daily</td>
			<td>Noise</td>
			<td>A gravel-like rattle at the suction usually means cavitation; a rising whine or rumble points to the bearings</td>
		</tr>
		<tr>
			<td>Daily</td>
			<td>Bearing temperature</td>
			<td>Feel or measure every bearing and compare with earlier readings, not just with a limit</td>
		</tr>
		<tr>
			<td>Daily</td>
			<td>Bearing oil and leaks</td>
			<td>Water or discoloration in the oil; oil leaking at gaskets</td>
		</tr>
		<tr>
			<td>Daily</td>
			<td>Seal and packing leakage</td>
			<td>Mechanical seal leakage within the maker's limit; packing leakage typically 2&ndash;60 drops per minute</td>
		</tr>
		<tr>
			<td>Daily</td>
			<td>Seal flush and cooling</td>
			<td>Flush flow or flush line temperature; cooling water flowing through jackets and coolers</td>
		</tr>
		<tr>
			<td>Monthly</td>
			<td>Lubrication</td>
			<td>Top up oil, clean oiler bulbs and sight glasses, and check the oil level against the shaft centerline</td>
		</tr>
		<tr>
			<td>Monthly</td>
			<td>Guards and housekeeping</td>
			<td>Guards in place, debris cleared from the bearing bracket, drain holes open</td>
		</tr>
		<tr>
			<td>Every 6 months</td>
			<td>Standby pumps</td>
			<td>Turn the shaft by hand several turns to coat the bearings with oil; protect exposed machined surfaces from rust</td>
		</tr>
		<tr>
			<td>Yearly</td>
			<td>Alignment and coupling</td>
			<td>Check alignment with a dial indicator, allowing for thermal growth; inspect the coupling for wear and cracks; check the axial float</td>
		</tr>
		<tr>
			<td>Continuous trend</td>
			<td>Vibration and performance</td>
			<td>Rising vibration, or falling flow and head at the same speed, means wear inside the pump</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Do not keep tightening packing to stop a leak. Overtightened packing wears the shaft sleeve and raises power consumption. If it has to be tightened excessively, replace it.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="why-worn-clearances-cost-efficiency-and-reliability--2">Why Worn Clearances Cost Efficiency and Reliability</h2><a class="header-anchor" href="#why-worn-clearances-cost-efficiency-and-reliability--2" title="Why Worn Clearances Cost Efficiency and Reliability" aria-label="Why Worn Clearances Cost Efficiency and Reliability"></a></div>

<p>A centrifugal pump relies on small gaps between rotating and stationary parts to keep high-pressure liquid at the discharge from flowing back to the suction. As those gaps wear open, more liquid recirculates inside the pump. The pump keeps running, but it delivers less flow and head for the same power.</p>

<p>The losses are significant. The U.S. Department of Energy notes that erosion of wear rings and the rotor can reduce a pump's wire-to-water efficiency by 10% or more. In a worked example by pump engineer Lev Nelik, doubling the wear ring clearance on a double-suction pump rated at 8,000 gpm and 400 ft (about 1,800 m&sup3;/h at 122 m) lets about 4% of the rated flow leak back. At roughly 900 hp, that wastes about 27 kW, or around $23,600 a year at $0.10/kWh in continuous service.</p>

<p>Energy is only part of the cost. As the video explains, open clearances also raise thrust loads and seal chamber pressure, which shortens bearing and seal life.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="wet-end-inspection-what-to-check-on-each-part--3">Wet-End Inspection: What to Check on Each Part</h2><a class="header-anchor" href="#wet-end-inspection-what-to-check-on-each-part--3" title="Wet-End Inspection: What to Check on Each Part" aria-label="Wet-End Inspection: What to Check on Each Part"></a></div>

<p>In a back pull-out end-suction pump, the wet end has three parts: the casing (volute), the impeller and the stuffing box cover, also called the seal chamber cover or back plate. When a back pull-out assembly is exchanged, the casing usually stays bolted into the piping, so it is easy to skip. Inspect it anyway: it is often the oldest part of the pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="casing-volute--4">Casing (volute)</h3><a class="header-anchor" href="#casing-volute--4" title="Casing (volute)" aria-label="Casing (volute)"></a></div>

<ul>
	<li>Grooves across the face that runs next to the impeller.</li>
	<li>Cracks, irregularities or washouts at the gasket surface.</li>
	<li>The cutwater. It should be smooth and straight across; a worn or washed-out cutwater lets more liquid recirculate around the volute.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="impeller--5">Impeller</h3><a class="header-anchor" href="#impeller--5" title="Impeller" aria-label="Impeller"></a></div>

<ul>
	<li>Grooves or general wear on the face that runs next to the casing.</li>
	<li>Bent vanes.</li>
	<li>The back pump-out vanes: their height and whether the edges are still sharp.</li>
	<li>The threads, and the face that seats against the shaft sleeve.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="stuffing-box-cover--6">Stuffing box cover</h3><a class="header-anchor" href="#stuffing-box-cover--6" title="Stuffing box cover" aria-label="Stuffing box cover"></a></div>

<ul>
	<li>Wear, grooves or pitting on the face that runs next to the impeller.</li>
	<li>The gasket surface against the casing.</li>
	<li>The bore where the shaft sleeve passes through.</li>
	<li>The face where the mechanical seal mounts.</li>
	<li>The register that locates the cover on the frame adapter.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="wear-limits-when-to-reuse-and-when-to-replace--7">Wear Limits: When to Reuse and When to Replace</h2><a class="header-anchor" href="#wear-limits-when-to-reuse-and-when-to-replace--7" title="Wear Limits: When to Reuse and When to Replace" aria-label="Wear Limits: When to Reuse and When to Replace"></a></div>

<p>The video gives clear limits for reusing wet-end parts on an end-suction pump. Lay a straight edge across each face to judge the depth of grooves and general wear.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Part</th>
			<th>Area</th>
			<th>Replace when</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Casing</td>
			<td>Face next to the impeller</td>
			<td>Grooves or irregularities deeper than 1/8 in (3.2 mm)</td>
		</tr>
		<tr>
			<td>Impeller</td>
			<td>Face next to the casing</td>
			<td>Wear or grooves deeper than 1/16 in (1.6 mm)</td>
		</tr>
		<tr>
			<td>Impeller</td>
			<td>Vanes</td>
			<td>Any vane is bent</td>
		</tr>
		<tr>
			<td>Impeller</td>
			<td>Back pump-out vanes</td>
			<td>Worn by more than 1/32 in (0.8 mm), or edges rounded by abrasion</td>
		</tr>
		<tr>
			<td>Stuffing box cover</td>
			<td>Face next to the impeller</td>
			<td>Grooves or general wear of 1/8 in (3.2 mm) or more</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Where your pump manufacturer gives tighter limits, use those. A part just inside the limit can go back in, but expect some extra leakage and a small loss of efficiency. The video shows a stuffing box cover with grooves just under 1/8 in that falls into exactly this category, and a suction side plate with grooves deep enough that it should not be reused.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="setting-open-impeller-clearance--8">Setting Open Impeller Clearance</h2><a class="header-anchor" href="#setting-open-impeller-clearance--8" title="Setting Open Impeller Clearance" aria-label="Setting Open Impeller Clearance"></a></div>

<p>Open and semi-open impellers run with a small axial gap to the casing. For the mid-size ANSI pump in the video, the operating manual calls for 0.008 in (0.20 mm) at service temperatures of 200 &deg;F (93 &deg;C) or below. With the impeller set there, the gaps in front of and behind the impeller typically add up to 0.060&ndash;0.085 in (1.5&ndash;2.2 mm) between the casing and the stuffing box cover.</p>

<p>The right setting depends on temperature. Parts grow as they heat up, so hot service needs a larger cold setting. One of the casings in the video came from a pump set at the standard 0.008 in while the process ran above 300 &deg;F (about 150 &deg;C). The impeller grew into the casing, the two rubbed, and the casing was heavily worn.</p>

<p>On pumps that adjust with jack bolts and locking bolts on the bearing housing, the usual procedure is:</p>

<ol>
	<li>Lock out the driver, then remove the coupling guard and the coupling.</li>
	<li>Mount a dial indicator with its button on the end of the shaft.</li>
	<li>Back out the jack bolts, then tighten the locking bolts evenly until the impeller just touches the casing. Zero the indicator.</li>
	<li>Back off the locking bolts, then tighten the jack bolts evenly to push the housing out until the indicator shows the specified clearance.</li>
	<li>Tighten the locking bolts evenly while the jack bolts hold the setting, and check that the shaft turns freely by hand.</li>
</ol>

<p>Some designs adjust with shims or an adjusting nut instead. Follow the manual for your pump. For more on the impeller types themselves, see <a href="https://www.shinjopump.com/news/what-is-the-differences-between-open-impeller-semi-open-impeller-and-closed-impeller.html">open, semi-open and closed impellers</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="the-trap-chasing-clearance-toward-the-casing--9">The Trap: Chasing Clearance Toward the Casing</h2><a class="header-anchor" href="#the-trap-chasing-clearance-toward-the-casing--9" title="The Trap: Chasing Clearance Toward the Casing" aria-label="The Trap: Chasing Clearance Toward the Casing"></a></div>

<p>Because an open impeller is adjustable, it is tempting to keep moving it toward the casing as the faces wear. That restores the front clearance, but the impeller moves the same distance away from the stuffing box cover, and the back gap grows. The back pump-out vanes are designed to work across a small back gap, so a wider one causes trouble.</p>

<div class="sj-warn">
<div class="sj-warn-title">What happens when the back gap opens up</div>

<ul>
	<li><b>Higher thrust.</b> The back pump-out vanes lower the pressure behind the impeller and with it the axial thrust on the shaft. With a wide gap they lose effect, and very open clearances can lead to thrust bearing failures.</li>
	<li><b>Solids reach the seal.</b> The pump-out vanes no longer push particles outward, so more solids get into the seal area.</li>
	<li><b>Higher stuffing box pressure.</b> Packing leaks more heavily and mechanical seals fail sooner.</li>
</ul>
</div>

<p>Once the faces are worn past their limits, the fix is to restore or replace the parts, not to keep resetting the impeller.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="wear-rings-on-closed-impellers-and-split-case-pumps--10">Wear Rings on Closed Impellers and Split-Case Pumps</h2><a class="header-anchor" href="#wear-rings-on-closed-impellers-and-split-case-pumps--10" title="Wear Rings on Closed Impellers and Split-Case Pumps" aria-label="Wear Rings on Closed Impellers and Split-Case Pumps"></a></div>

<p>Closed impellers, including the double-suction impellers in split-case pumps, seal against the casing with wear rings rather than an axial gap. The video notes that on split-case pumps the total clearance between the impeller ring and the casing ring is typically only 0.020&ndash;0.040 in (0.5&ndash;1.0 mm), depending on pump size and ring material. Wear rings cannot be adjusted, so the only cure for wear is new rings.</p>

<p>One fits-and-clearances checklist based on Hydraulic Institute standards gives this guide for the new diametral clearance between impeller ring and casing ring, for rings up to 12 in (305 mm) in diameter:</p>

<p class="sj-formula">Clearance = 0.010&ndash;0.012 in + 0.001 in per inch of ring diameter<br>
Example, 8 in (203 mm) ring: 0.018&ndash;0.020 in (0.46&ndash;0.51 mm)</p>

<p>Add 0.005 in (0.13 mm) for materials that tend to gall, such as stainless steel.</p>

<ul>
	<li><strong>When to renew them.</strong> The same checklist says to renew the rings when the clearance reaches twice the original value. Some manufacturers replace them sooner, when the clearance has grown by 40%.</li>
	<li><strong>Rear rings.</strong> Excessive clearance at the rear rings raises axial thrust and can damage the thrust bearing.</li>
	<li><strong>Fitting.</strong> Rings are pressed on with 0.002&ndash;0.003 in (0.05&ndash;0.08 mm) interference and locked with dowels or tack welds in at least two places. Do not bore out a casing ring seat by more than 3% of its original diameter.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="fits-and-clearances-to-check-on-reassembly--11">Fits and Clearances to Check on Reassembly</h2><a class="header-anchor" href="#fits-and-clearances-to-check-on-reassembly--11" title="Fits and Clearances to Check on Reassembly" aria-label="Fits and Clearances to Check on Reassembly"></a></div>

<p>A precision rebuild also restores the fits that keep the rotor running true. The values below come from the same checklist. Use the pump maker's figures where they differ.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Fit</th>
			<th>Inches</th>
			<th>Millimeters</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Ball bearing bore to shaft</td>
			<td>0.0001&ndash;0.0007 interference</td>
			<td>0.003&ndash;0.018 interference</td>
		</tr>
		<tr>
			<td>Ball bearing outside diameter to housing</td>
			<td>0.0001&ndash;0.001 clearance</td>
			<td>0.003&ndash;0.025 clearance</td>
		</tr>
		<tr>
			<td>Shaft sleeve to shaft</td>
			<td>0.001&ndash;0.0015 clearance</td>
			<td>0.025&ndash;0.038 clearance</td>
		</tr>
		<tr>
			<td>Impeller to shaft</td>
			<td>Metal to metal, up to 0.0005 clearance</td>
			<td>Metal to metal, up to 0.013 clearance</td>
		</tr>
		<tr>
			<td>Coupling hub to shaft</td>
			<td>Metal to metal, up to 0.0005 clearance</td>
			<td>Metal to metal, up to 0.013 clearance</td>
		</tr>
		<tr>
			<td>Throat bushing to shaft</td>
			<td>0.015&ndash;0.020 clearance</td>
			<td>0.38&ndash;0.51 clearance</td>
		</tr>
		<tr>
			<td>Seal gland throttle bushing to shaft</td>
			<td>0.018&ndash;0.020 clearance</td>
			<td>0.46&ndash;0.51 clearance</td>
		</tr>
		<tr>
			<td>Seal gland pilot to stuffing box</td>
			<td>0.002&ndash;0.004 clearance</td>
			<td>0.05&ndash;0.10 clearance</td>
		</tr>
		<tr>
			<td>Casing, cover and bearing housing alignment</td>
			<td>0.004 maximum</td>
			<td>0.10 maximum</td>
		</tr>
		<tr>
			<td>Mechanical seal faces</td>
			<td>Flat within 3 helium light bands</td>
			<td>About 0.0009</td>
		</tr>
	</tbody>
</table></div>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="abrasive-wear-reading-the-damage--12">Abrasive Wear: Reading the Damage</h2><a class="header-anchor" href="#abrasive-wear-reading-the-damage--12" title="Abrasive Wear: Reading the Damage" aria-label="Abrasive Wear: Reading the Damage"></a></div>

<p>The last end-suction example in the video is a back pull-out assembly from abrasive service, and every wet-end surface shows it. The vanes and the impeller face are worn and uneven. The back pump-out vanes are nearly gone. The stuffing box cover is cupped from the center outward, and the casing has heavy washout near the cutwater.</p>

<p>In abrasive duty, plan for faster wear:</p>

<ul>
	<li>Shorten the inspection interval and trend performance, so parts are replaced before they pass their limits.</li>
	<li>Keep the pump near its best efficiency point. At low flow, liquid recirculates inside the pump and wears it faster.</li>
	<li>Choose harder materials, or a pump designed for solids, such as a <a href="https://www.shinjopump.com/slurry-pumps.html">slurry pump</a>.</li>
	<li>Protect the mechanical seal from solids with a suitable flush, and keep the back pump-out vanes in good condition.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="centrifugal-pump-repair-or-replacement--13">Centrifugal Pump Repair or Replacement?</h2><a class="header-anchor" href="#centrifugal-pump-repair-or-replacement--13" title="Centrifugal Pump Repair or Replacement?" aria-label="Centrifugal Pump Repair or Replacement?"></a></div>

<p>A rebuild makes sense when the casing is sound and the wet-end parts can be brought back within limits. Consider a new pump or a new back pull-out assembly instead when:</p>

<ul>
	<li>The casing is cracked, washed out at the gasket face or grooved beyond 1/8 in, and cannot be repaired by building up and re-machining.</li>
	<li>The impeller has bent vanes or wear beyond the limits, and the parts would cost close to a new assembly.</li>
	<li>The pump runs far from its best efficiency point. A pump that does not suit its duty will keep wearing the same way, so check the operating point on the <a href="https://www.shinjopump.com/news/what-is-a-pump-performance-curve.html">pump performance curve</a> and reselect if needed. Our guide on <a href="https://www.shinjopump.com/news/how-to-select-a-centrifugal-pump.html">how to select a centrifugal pump</a> covers the process.</li>
	<li>Failures keep returning at short intervals even after careful rebuilds. Find the root cause first, whether it is the operating point, the piping or the liquid.</li>
</ul>

<p>If you are sourcing a replacement, see our comparison of <a href="https://www.shinjopump.com/news/top-centrifugal-pump-suppliers-china-buyer-guide.html">centrifugal pump suppliers in China</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="centrifugal-pumps-built-for-easy-maintenance--14">Centrifugal Pumps Built for Easy Maintenance</h2><a class="header-anchor" href="#centrifugal-pumps-built-for-easy-maintenance--14" title="Centrifugal Pumps Built for Easy Maintenance" aria-label="Centrifugal Pumps Built for Easy Maintenance"></a></div>

<p>The pump layout decides how quickly and accurately centrifugal pump maintenance can be done.</p>

<ul>
	<li><strong><a href="https://www.shinjopump.com/is-horizontal-clean-water-centrifugal-pump-capacity-5-400-m3-h.html">IS horizontal clean water centrifugal pump</a>.</strong> Built to ISO 2858 dimensions with a back pull-out layout: the casing and cover separate behind the impeller. Remove the coupling spacer and the rotor comes out without disturbing the casing, the suction and discharge piping or the motor. Flows up to 400 m&sup3;/h and heads up to 125 m, for clean water up to 80 &deg;C.</li>
	<li><strong><a href="https://www.shinjopump.com/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion.html">IH stainless steel chemical centrifugal pump</a>.</strong> The same back pull-out layout for corrosive liquids.</li>
	<li><strong><a href="https://www.shinjopump.com/horizontal-split-case-pump-flow-capacity-160-3750-m3h.html">Horizontal split-case pump</a>.</strong> The casing splits along the shaft line, so the upper half lifts off for access to the rotor and wear rings while the pipework stays connected.</li>
</ul>

<div class="sj-gallery sj-g3">
<figure><a href="https://www.shinjopump.com/is-horizontal-clean-water-centrifugal-pump-capacity-5-400-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal%20Pumps/is-horizontal-clean-water-centrifugal-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/6db7146e9b975ce3dc065b8b559912e3/is-horizontal-clean-water-centrifugal-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/6db7146e9b975ce3dc065b8b559912e3/is-horizontal-clean-water-centrifugal-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo IS horizontal end-suction centrifugal pump with back pull-out design" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo IS horizontal end-suction centrifugal pump with back pull-out design' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>IS Clean Water Pump</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Chemical%20Process%20Pumps/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Chemical Process Pumps/resize/a4d5cf8b4164adf36c33037d9e557973/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Chemical Process Pumps/resize/a4d5cf8b4164adf36c33037d9e557973/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo IH stainless steel chemical centrifugal pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo IH stainless steel chemical centrifugal pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>IH Chemical Pump</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/horizontal-split-case-pump-flow-capacity-160-3750-m3h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Split%20Case%20Pumps/horizontal-split-case-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Split Case Pumps/resize/5a2b51f7382595449b8833ce78f2e863/horizontal-split-case-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Split Case Pumps/resize/5a2b51f7382595449b8833ce78f2e863/horizontal-split-case-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo horizontal split-case double-suction pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo horizontal split-case double-suction pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>Split-case pump</figcaption>
</figure>
</div>

<p>Shinjo supports its pumps with spare parts, remote technical support and video installation guidance.</p>

<p class="sj-cta">Planning a pump rebuild or a replacement? Send SHINJO the pump model, the duty and photos of the worn parts, and we will <a href="https://www.shinjopump.com/contact.html">recommend spare parts or a replacement pump</a>. See our full ranges of <a href="https://www.shinjopump.com/centrifugal-pumps.html">centrifugal pumps</a> and <a href="https://www.shinjopump.com/split-case-pumps.html">split-case pumps</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="faq--15">FAQ</h2><a class="header-anchor" href="#faq--15" title="FAQ" aria-label="FAQ"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="how-often-should-a-centrifugal-pump-be-maintained--16">How often should a centrifugal pump be maintained?</h3><a class="header-anchor" href="#how-often-should-a-centrifugal-pump-be-maintained--16" title="How often should a centrifugal pump be maintained?" aria-label="How often should a centrifugal pump be maintained?"></a></div>

<p>Check noise, bearing temperature and leakage daily, lubrication monthly, and alignment and the coupling once a year. Open the pump for a rebuild when trends show falling performance, rising vibration or repeated seal leaks, rather than on a fixed calendar.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="what-is-the-correct-impeller-clearance-for-a-centrifugal-pump--17">What is the correct impeller clearance for a centrifugal pump?</h3><a class="header-anchor" href="#what-is-the-correct-impeller-clearance-for-a-centrifugal-pump--17" title="What is the correct impeller clearance for a centrifugal pump?" aria-label="What is the correct impeller clearance for a centrifugal pump?"></a></div>

<p>Use the value in the pump's operating manual for your service temperature. For example, the video quotes 0.008 in (0.20 mm) for a mid-size ANSI pump at 200 &deg;F (93 &deg;C) or below. Hot service needs a larger cold setting to allow for thermal growth.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="when-should-wear-rings-be-replaced--18">When should wear rings be replaced?</h3><a class="header-anchor" href="#when-should-wear-rings-be-replaced--18" title="When should wear rings be replaced?" aria-label="When should wear rings be replaced?"></a></div>

<p>A common rule is to renew them when the clearance reaches twice its original value. Some manufacturers replace them sooner, when the clearance has grown by 40%. Wear rings cannot be adjusted, so new rings are the only way to restore the clearance.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="why-does-my-mechanical-seal-keep-failing-after-a-pump-rebuild--19">Why does my mechanical seal keep failing after a pump rebuild?</h3><a class="header-anchor" href="#why-does-my-mechanical-seal-keep-failing-after-a-pump-rebuild--19" title="Why does my mechanical seal keep failing after a pump rebuild?" aria-label="Why does my mechanical seal keep failing after a pump rebuild?"></a></div>

<p>Check the back clearance. If the impeller was moved toward the casing to make up for front wear, the gap to the stuffing box cover grows. The back pump-out vanes then stop clearing solids from the seal area and the stuffing box pressure rises. Worn pump-out vanes have the same effect.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-grooved-impeller-or-casing-be-reused--20">Can a grooved impeller or casing be reused?</h3><a class="header-anchor" href="#can-a-grooved-impeller-or-casing-be-reused--20" title="Can a grooved impeller or casing be reused?" aria-label="Can a grooved impeller or casing be reused?"></a></div>

<p>Only within limits. In the video, casing grooves up to 1/8 in (3.2 mm) and impeller face wear up to 1/16 in (1.6 mm) are acceptable, while any bent vane means a new impeller. Parts close to the limit still work, but with some extra leakage and lower efficiency.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="how-can-i-extend-the-life-of-a-centrifugal-pump--21">How can I extend the life of a centrifugal pump?</h3><a class="header-anchor" href="#how-can-i-extend-the-life-of-a-centrifugal-pump--21" title="How can I extend the life of a centrifugal pump?" aria-label="How can I extend the life of a centrifugal pump?"></a></div>

<p>Run it near its best efficiency point, keep lubrication and alignment in order, and trend vibration and performance. When the pump is opened, rebuild it to as-new clearances instead of replacing only the bearings and the seal.</p>
</div></div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>Double Diaphragm Pump Buyer's Guide: Size, Build, Diaphragms</title>
      <description><![CDATA[How to buy a double diaphragm pump: size by duty not port, choose the housing and diaphragm, set replacement intervals, compare air and electric drives.]]></description>
      <pubDate>Sun, 18 Oct 2026 03:23:20 +0000</pubDate>
      <link>https://www.shinjopump.com/news/double-diaphragm-pump.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/double-diaphragm-pump.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content"><div class="shinjopump-pillar">
<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="abstract--0" class="scrollspy-head">Abstract</h2><a class="header-anchor" href="#abstract--0" title="Abstract" aria-label="Abstract"></a></div>

<p>A double diaphragm pump is bought once, and its diaphragms are bought for as long as it runs. Four choices decide what the pump costs to keep: port size against the real duty, the housing and its build, the diaphragm construction for the liquid, and the spares supply. The diaphragm flexes as the pump strokes and is the part a buyer keeps replacing, so its construction and supply belong in the specification. A quote that leaves these choices open leaves the buyer to settle them in service.</p>

<figure class="wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/double-diaphragm-pump-aodd-skid-air-line-1920_Hlx7IY.webp" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/d8950215a9ecdb81fd8d1c4d3d66e949/double-diaphragm-pump-aodd-skid-air-line-1920_Hlx7IY-320x180.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/d8950215a9ecdb81fd8d1c4d3d66e949/double-diaphragm-pump-aodd-skid-air-line-1920_Hlx7IY-640x360.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/d8950215a9ecdb81fd8d1c4d3d66e949/double-diaphragm-pump-aodd-skid-air-line-1920_Hlx7IY-800x450.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/d8950215a9ecdb81fd8d1c4d3d66e949/double-diaphragm-pump-aodd-skid-air-line-1920_Hlx7IY-1024x576.webp 1024w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/d8950215a9ecdb81fd8d1c4d3d66e949/double-diaphragm-pump-aodd-skid-air-line-1920_Hlx7IY-1280x720.webp 1280w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/d8950215a9ecdb81fd8d1c4d3d66e949/double-diaphragm-pump-aodd-skid-air-line-1920_Hlx7IY-1600x900.webp 1600w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/d8950215a9ecdb81fd8d1c4d3d66e949/double-diaphragm-pump-aodd-skid-air-line-1920_Hlx7IY-1920x1080.webp 1920w" width="1920" height="1080"  
      alt="Air-operated double diaphragm pump on a skid with its filter-regulator, gauge and flexible liquid hoses" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Air-operated double diaphragm pump on a skid with its filter-regulator, gauge and flexible liquid hoses' loading='lazy'  sizes="(max-width: 1920px) 96vw, 1920px"  />
<figcaption>An air-operated double diaphragm pump on its skid: air enters through the filter-regulator, and liquid enters at the bottom manifold and leaves at the top.</figcaption>
</figure>

<p>This guide is for procurement and project engineers who specify an industrial diaphragm pump and keep it running. They choose single or double design, port size, and the housing and valves. The diaphragm needs choices of its own: rubber, TPE or PTFE construction, and a replacement interval learned on the pump's own duty. The purchase turns on air or electric drive, what the quote must state, and how to check the supplier behind it. Readers are assumed to know <a href="https://www.shinjopump.com/news/diaphragm-pump.html" rel="noopener" target="_blank">how the pump works</a> and how to size its compressed-air supply.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="key-takeaways--1" class="scrollspy-head">Key Takeaways</h2><a class="header-anchor" href="#key-takeaways--1" title="Key Takeaways" aria-label="Key Takeaways"></a></div>

<ul>
	<li><strong>Port size is not the duty:</strong> All-Flo's 25 mm (1 in) ball-valve pumps peak at 155.8-182 L/min (41-48 US gpm) (All-Flo, n.d.).</li>
	<li><strong>Size up one port size</strong> so the pump runs at fewer strokes per minute and lasts longer (Versamatic, n.d.).</li>
	<li><strong>Rubber, TPE and PTFE diaphragms</strong> trade flex life, chemical range and cost; none leads on all three (Caldwell, 2022).</li>
	<li><strong>Count strokes to set a replacement interval.</strong> No standard schedule exists (Dill, 2022); the pump's own stroke history decides it.</li>
	<li><strong>Bolted pumps seal more easily</strong> for hazardous liquids; clamped pumps come apart with very few tools.</li>
	<li><strong>A double diaphragm pump quote should state</strong> materials by part, diaphragm grade, test standard and a spares list.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="table-of-contents--2" class="scrollspy-head">Table of Contents</h2><a class="header-anchor" href="#table-of-contents--2" title="Table of Contents" aria-label="Table of Contents"></a></div>

<ul>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#abstract">Abstract</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#key-takeaways">Key Takeaways</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#what-a-double-diaphragm-pump-is-and-single-vs-double">What a double diaphragm pump is, and single vs double</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#sizing-a-1-diaphragm-pump-and-every-other-port-size">Sizing a 1" diaphragm pump and every other port size</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#industrial-diaphragm-pump-construction-choices">Industrial diaphragm pump construction choices</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#the-diaphragm-pump-diaphragm-types-life-and-replacement">The diaphragm pump diaphragm: types, life and replacement</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#air-operated-or-electric-double-diaphragm-pump">Air-operated or electric double diaphragm pump</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#running-practices-that-decide-diaphragm-life">Running practices that decide diaphragm life</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#reading-a-quote-for-a-double-diaphragm-pump">Reading a quote for a double diaphragm pump</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#how-to-evaluate-diaphragm-pump-suppliers">How to evaluate diaphragm pump suppliers</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#frequently-asked-questions">Frequently Asked Questions</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#conclusion">Conclusion</a></li>
	<li><a href="https://www.shinjopump.com/news/double-diaphragm-pump.html#references">References</a></li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="what-a-double-diaphragm-pump-is-and-single-vs-double--3" class="scrollspy-head">What a double diaphragm pump is, and single vs double</h2><a class="header-anchor" href="#what-a-double-diaphragm-pump-is-and-single-vs-double--3" title="What a double diaphragm pump is, and single vs double" aria-label="What a double diaphragm pump is, and single vs double"></a></div>

<p>A double diaphragm pump is a positive displacement pump with two diaphragms on one shaft, each sealing its own liquid chamber (Yamada Pump, n.d.). While one diaphragm pushes liquid out of its chamber, the other draws liquid into the opposite chamber (Yamada Pump, n.d.). The drive is compressed air or an electric motor. The air-driven type falls under ANSI/HI 10.1-10.5, the Hydraulic Institute standard for positive displacement reciprocating pumps driven by compressed gas.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="two-chambers-on-one-shaft--4" class="scrollspy-head">Two chambers on one shaft</h3><a class="header-anchor" href="#two-chambers-on-one-shaft--4" title="Two chambers on one shaft" aria-label="Two chambers on one shaft"></a></div>

<p>Yamada describes two diaphragms on a common center shaft, "always evacuating one chamber while filling the other" (Yamada Pump, n.d.). Most standard pumps carry two diaphragms and four check balls, by Yamada's account (Yamada Pump, n.d.).</p>

<p>Versamatic defines the two counting units: "A stroke is one shift of the diaphragm assembly moving fluid out of one chamber. A cycle is two strokes" (Versamatic, n.d.). Flow equals strokes per minute times displacement per stroke (Versamatic, n.d.). By that definition, a double pump discharges on every stroke, twice per cycle. The flow still pulses rather than running steady: All-Flo's pulsation dampeners fit at the pump's discharge to reduce pressure and flow fluctuations (All-Flo, n.d.).</p>

<blockquote class="callout callout-note">
<p><strong>Note:</strong> For the working principle, the air valve and a part-by-part walk-through, read our <a href="https://www.shinjopump.com/news/diaphragm-pump.html" rel="noopener" target="_blank">beginner's guide to the diaphragm pump</a>.</p>
</blockquote>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="single-diaphragm-vs-double-diaphragm--5" class="scrollspy-head">Single diaphragm vs double diaphragm</h3><a class="header-anchor" href="#single-diaphragm-vs-double-diaphragm--5" title="Single diaphragm vs double diaphragm" aria-label="Single diaphragm vs double diaphragm"></a></div>

<p>Both layouts exist, and they differ in how often liquid leaves the pump.</p>

<p>The Hydraulic Institute's <a href="https://www.pumps.org/resources/pump-faqs" rel="noopener nofollow" target="_blank">pump FAQs</a> set the two layouts side by side as duplex and simplex air-operated pumps. In a duplex pump, one air chamber pressurizes its diaphragm and pushes liquid out while the opposite chamber exhausts and liquid is drawn in. A simplex pump works the same way, except that no liquid is discharged during the diaphragm's recharge stroke, which a spring return typically drives.</p>

<p>A single diaphragm pump has one liquid chamber, which must refill before it can discharge again. A double pump discharges from one chamber while the other refills. In its <a href="https://www.sandpiperpump.com/blog/everything-you-need-to-know-about-electric-diaphragm-pumps" rel="noopener nofollow" target="_blank">guide to electric diaphragm pumps</a>, Sandpiper notes that single diaphragm pumps are "typically used in applications requiring lower flow rates and pressures".</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="other-names-for-the-same-pump--6" class="scrollspy-head">Other names for the same pump</h3><a class="header-anchor" href="#other-names-for-the-same-pump--6" title="Other names for the same pump" aria-label="Other names for the same pump"></a></div>

<p>Double diaphragm pumps are also sold as dual diaphragm pumps. The air-driven type is the air-operated double diaphragm pump, or AODD pump. The motor-driven type is the electric double diaphragm pump, or EODD (Graco, n.d.). Graco gives "membrane pump" as another name for the diaphragm pump in general (Graco, n.d.).</p>

<p>Metering pumps use the phrase differently: in <a href="https://www.miltonroy.com/en/technologies/double-diaphragm-metering-pumps" rel="noopener nofollow" target="_blank">Milton Roy's double diaphragm metering pumps</a>, two diaphragms work in tandem, and the maker notes that a double diaphragm does not automatically imply leak detection.</p>

<p>Whatever the name on the quote, the specification starts with the duty: the liquid, the flow and the head the pump must meet. Port size comes after that, and it does not set the flow on its own.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="sizing-a-1-diaphragm-pump-and-every-other-port-size--7" class="scrollspy-head">Sizing a 1" diaphragm pump and every other port size</h2><a class="header-anchor" href="#sizing-a-1-diaphragm-pump-and-every-other-port-size--7" title="Sizing a 1" diaphragm pump and every other port size" aria-label="Sizing a 1" diaphragm pump and every other port size"></a></div>

<p>Port size fixes the pipe connection and, through the housing behind it, a ceiling on flow. Makers publish that ceiling as a model's maximum flow. A buyer reads those figures as limits and sizes a double diaphragm pump from its duty.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="maximum-flow-by-port-size--8" class="scrollspy-head">Maximum flow by port size</h3><a class="header-anchor" href="#maximum-flow-by-port-size--8" title="Maximum flow by port size" aria-label="Maximum flow by port size"></a></div>

<p>Ball-valve 1-inch (25 mm) double diaphragm pumps from All-Flo, Yamada and ARO carry maximum ratings of 155.8 to 182 L/min (41 to 48 US gpm), on water at maximum air pressure and open discharge (All-Flo, n.d.) (Yamada Pump, n.d.) (ARO, n.d.). Sandpiper rates its 1-inch HDF1 flap-valve pump to 265 L/min (70 US gpm) (Sandpiper, n.d.).</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Port size</th>
			<th>Maximum flow, US gpm</th>
			<th>Maximum flow, L/min</th>
			<th>Valve type note</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>1/4 in (6 mm)</td>
			<td>3.4-5.7 (Yamada Pump, n.d.) (All-Flo, n.d.)</td>
			<td>12.9-21.6</td>
			<td>Low: Yamada NDP-5; high: All-Flo A025 plastic</td>
		</tr>
		<tr>
			<td>3/8 in (10 mm)</td>
			<td>6.0-9 (Yamada Pump, n.d.) (All-Flo, n.d.)</td>
			<td>22.7-34</td>
			<td>Low: Yamada DP-10; high: All-Flo C038</td>
		</tr>
		<tr>
			<td>1/2 in (13-15 mm)</td>
			<td>8.0-17 (Yamada Pump, n.d.) (All-Flo, n.d.)</td>
			<td>30.3-64.6</td>
			<td>Low: Yamada DP-15; high: All-Flo A050 plastic</td>
		</tr>
		<tr>
			<td>3/4 in (19-20 mm)</td>
			<td>15-31.7 (All-Flo, n.d.) (Yamada Pump, n.d.)</td>
			<td>56.8-120.0</td>
			<td>Low: All-Flo A075 metal; high: Yamada NDP-20</td>
		</tr>
		<tr>
			<td>1 in (25 mm)</td>
			<td>41-48 (All-Flo, n.d.)</td>
			<td>155.8-182</td>
			<td>Ball valve: All-Flo, Yamada, ARO (Yamada Pump, n.d.) (ARO, n.d.). Sandpiper HDF1 flap valve at 265 L/min (70 US gpm) sits outside the range (Sandpiper, n.d.)</td>
		</tr>
		<tr>
			<td>1-1/2 in (38-40 mm)</td>
			<td>90-130 (ARO, n.d.) (All-Flo, n.d.)</td>
			<td>340-492</td>
			<td>Low: ARO; high: All-Flo C150 plastic</td>
		</tr>
		<tr>
			<td>2 in (50-51 mm)</td>
			<td>132-208 (ARO, n.d.) (Sandpiper, n.d.)</td>
			<td>500-787</td>
			<td>Low: ARO; high: Sandpiper HDF2 flap valve</td>
		</tr>
		<tr>
			<td>3 in (76-80 mm)</td>
			<td>230-310 (ARO, n.d.) (Sandpiper, n.d.)</td>
			<td>870-1,173</td>
			<td>Low: ARO; high: Sandpiper HDF3 flap valve</td>
		</tr>
		<tr>
			<td>4 in (100-102 mm)</td>
			<td>280-310 (ARO, n.d.) (Sandpiper, n.d.)</td>
			<td>1,060-1,173</td>
			<td>Low: ARO; high: Sandpiper HDF4 flap valve</td>
		</tr>
	</tbody>
</table></div>

<p><em>Each figure is one model's maximum rating on water at maximum air pressure and open discharge; a range is the spread of several makers' maxima at that port size, never an operating flow.</em></p>

<figure class="wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/1-inch-diaphragm-pump-maximum-flow-by-port-size-1920_pjlyWr.webp" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/f02ca4985e38291b6d712eb7c7df74f0/1-inch-diaphragm-pump-maximum-flow-by-port-size-1920_pjlyWr-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/f02ca4985e38291b6d712eb7c7df74f0/1-inch-diaphragm-pump-maximum-flow-by-port-size-1920_pjlyWr-640x640.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/f02ca4985e38291b6d712eb7c7df74f0/1-inch-diaphragm-pump-maximum-flow-by-port-size-1920_pjlyWr-800x800.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/f02ca4985e38291b6d712eb7c7df74f0/1-inch-diaphragm-pump-maximum-flow-by-port-size-1920_pjlyWr-1024x1024.webp 1024w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/f02ca4985e38291b6d712eb7c7df74f0/1-inch-diaphragm-pump-maximum-flow-by-port-size-1920_pjlyWr-1280x1280.webp 1280w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/f02ca4985e38291b6d712eb7c7df74f0/1-inch-diaphragm-pump-maximum-flow-by-port-size-1920_pjlyWr-1600x1600.webp 1600w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/f02ca4985e38291b6d712eb7c7df74f0/1-inch-diaphragm-pump-maximum-flow-by-port-size-1920_pjlyWr-1920x1920.webp 1920w" width="1920" height="1920"  
      alt="Range chart of maximum flow by port size: 41-48 US gpm for a 1-inch ball-valve pump, 280-310 US gpm at 4 inches" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Range chart of maximum flow by port size: 41-48 US gpm for a 1-inch ball-valve pump, 280-310 US gpm at 4 inches' loading='lazy'  sizes="(max-width: 1920px) 96vw, 1920px"  />
<figcaption>Maximum flow by port size from Yamada, All-Flo, ARO and Sandpiper ratings: each band spans several makers' ceilings on water, never an operating flow.</figcaption>
</figure>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="why-port-size-is-not-the-duty--9" class="scrollspy-head">Why port size is not the duty</h3><a class="header-anchor" href="#why-port-size-is-not-the-duty--9" title="Why port size is not the duty" aria-label="Why port size is not the duty"></a></div>

<p>A double diaphragm pump's flow is strokes per minute multiplied by displacement per stroke (Versamatic, n.d.). Change either term and the flow moves with it. Diaphragm material changes the second: Yamada's 2018 product guide lists the NDP-40's discharge volume per cycle at 2.74 L (0.72 gal) with rubber diaphragms and 1.40 L (0.37 gal) with PTFE (Yamada America, 2018), roughly half the volume.</p>

<p>Makers' tables break the port-to-flow link too. All-Flo rates its 1/2-inch A050 and 3/4-inch A075 alike, at 56.8 L/min (15 US gpm) in metal and 64.6 L/min (17 US gpm) in plastic (All-Flo, n.d.), so the two ranges overlap. Sandpiper lists its 3-inch HDF3 and 4-inch HDF4 together at 1,173 L/min (310 US gpm) (Sandpiper, n.d.), the figure its <a href="https://www.sandpiperpump.com/pumps/hdf3-hdf4-metallic-aodd-heavy-duty-flap-valve-pumps" rel="noopener nofollow" target="_blank">HDF3 and HDF4 product page</a> gives for the aluminum build. Shinjo lists its <a href="https://www.shinjopump.com/diaphragm-pumps.html" rel="noopener" target="_blank">QBY3-25 and QBY3-25A</a>, both DN25, at 57 and 151 L/min maximum flow (15.1 and 39.9 US gpm): one port size, two ratings.</p>

<p>Head on the discharge line and a lower air supply both pull the operating point below these ratings. Reading that point off the curve and sizing the compressor are set out in <a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html" rel="noopener" target="_blank">Shinjo's guide to AODD sizing and air use</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="size-up-one-port-size--10" class="scrollspy-head">Size up one port size</h3><a class="header-anchor" href="#size-up-one-port-size--10" title="Size up one port size" aria-label="Size up one port size"></a></div>

<p>Versamatic advises going up one pump size whenever possible. A pump kept away from its maximum capacity runs at fewer strokes per minute, which cuts air use and extends pump life (Versamatic, n.d.). Yamada's version is shorter: "The longest running pumps are oversized and run slower" (Eklund, 2026). Yamada's <a href="https://www.yamadapump.com/is-ptfe-always-the-best-diaphragm-material/" rel="noopener nofollow" target="_blank">guidance on PTFE diaphragms</a> adds that a larger pump running more slowly may deliver the flow in fewer cycles, which may improve diaphragm life.</p>

<p>Sandpiper gives a worked example. A 1-inch (25 mm) double diaphragm pump can move 151 L/min (40 US gpm) of water against 3 m (10 ft) of head, but only near its maximum capacity and stroke rate. A pump one porting size up runs significantly slower, which extends pump life (Ellis, 2021). That duty sits just under 155.8 L/min, the rating of All-Flo's plastic A100 and the lowest 1-inch ball-valve maximum of the three makers (All-Flo, n.d.).</p>

<p>Versamatic and Sandpiper state the rule as one port-size step, and Yamada as oversizing. None of the three gives a percent-of-maximum figure, so ask any supplier who sizes a double diaphragm pump to a percentage for the source of that number.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="industrial-diaphragm-pump-construction-choices--11" class="scrollspy-head">Industrial diaphragm pump construction choices</h2><a class="header-anchor" href="#industrial-diaphragm-pump-construction-choices--11" title="Industrial diaphragm pump construction choices" aria-label="Industrial diaphragm pump construction choices"></a></div>

<p>Housing material, housing joints and valve type are the construction choices a buyer signs off on a double diaphragm pump. Each trades one property for another, such as chemical resistance against cost, or a tight seal against fast strip-down. Elastomer temperature limits and ball-valve particle sizes are explained in our pneumatic diaphragm pump guide.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="housing-material--12" class="scrollspy-head">Housing material</h3><a class="header-anchor" href="#housing-material--12" title="Housing material" aria-label="Housing material"></a></div>

<p>Versamatic rates the common housing materials for a double diaphragm pump in short, plain terms. A dash marks an attribute it does not rate.</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Material</th>
			<th>Strength and weight</th>
			<th>Chemical resistance</th>
			<th>Typical use or note</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Aluminum</td>
			<td>Strong, lighter</td>
			<td>Average (Caldwell, 2022)</td>
			<td>Popular in paint, oil, gas and mining</td>
		</tr>
		<tr>
			<td>Cast iron</td>
			<td>Very strong, heavy</td>
			<td>-</td>
			<td>Resists abrasion (Caldwell, 2022)</td>
		</tr>
		<tr>
			<td>Stainless steel</td>
			<td>-</td>
			<td>Excellent</td>
			<td>Food use (Caldwell, 2022)</td>
		</tr>
		<tr>
			<td>Alloy C</td>
			<td>-</td>
			<td>Very high</td>
			<td>Very costly (Caldwell, 2022)</td>
		</tr>
		<tr>
			<td>Polypropylene</td>
			<td>Light</td>
			<td>Strong for acids and caustics (Caldwell, 2022)</td>
			<td>Can be very affordable, depending on pump size</td>
		</tr>
		<tr>
			<td>PVDF</td>
			<td>Very strong plastic</td>
			<td>Higher than polypropylene</td>
			<td>Handles abrasion better than polypropylene (Caldwell, 2022)</td>
		</tr>
		<tr>
			<td>Conductive acetal</td>
			<td>-</td>
			<td>Much like polypropylene</td>
			<td>Prevents static discharge with flammable liquids (Caldwell, 2022)</td>
		</tr>
	</tbody>
</table></div>

<figure class="wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/industrial-diaphragm-pump-housing-aluminum-stainless-polypropylene-1920_OnUA4J.webp" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/0c4a847ea1a404092747db3befc23e23/industrial-diaphragm-pump-housing-aluminum-stainless-polypropylene-1920_OnUA4J-320x214.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/0c4a847ea1a404092747db3befc23e23/industrial-diaphragm-pump-housing-aluminum-stainless-polypropylene-1920_OnUA4J-640x428.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/0c4a847ea1a404092747db3befc23e23/industrial-diaphragm-pump-housing-aluminum-stainless-polypropylene-1920_OnUA4J-800x535.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/0c4a847ea1a404092747db3befc23e23/industrial-diaphragm-pump-housing-aluminum-stainless-polypropylene-1920_OnUA4J-1024x684.webp 1024w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/0c4a847ea1a404092747db3befc23e23/industrial-diaphragm-pump-housing-aluminum-stainless-polypropylene-1920_OnUA4J-1280x855.webp 1280w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/0c4a847ea1a404092747db3befc23e23/industrial-diaphragm-pump-housing-aluminum-stainless-polypropylene-1920_OnUA4J-1600x1069.webp 1600w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/0c4a847ea1a404092747db3befc23e23/industrial-diaphragm-pump-housing-aluminum-stainless-polypropylene-1920_OnUA4J-1920x1283.webp 1920w" width="1920" height="1283"  
      alt="Bolted aluminum, bolted stainless steel and polypropylene diaphragm pumps side by side on a workbench" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Bolted aluminum, bolted stainless steel and polypropylene diaphragm pumps side by side on a workbench' loading='lazy'  sizes="(max-width: 1920px) 96vw, 1920px"  />
<figcaption>Three housing materials on one bench: bolted aluminum, bolted stainless steel and polypropylene, each with its manifolds at top and bottom.</figcaption>
</figure>

<p>Sandpiper lists conductive grades of polypropylene, acetal and PVDF among its plastic housing options (Ellis, 2021), so a flammable liquid does not tie a buyer to acetal alone.</p>

<p>A housing rating describes a material family and says nothing final about a specific liquid. Check the actual liquid, at its concentration and temperature, against the maker's compatibility guide for every wetted part. Graco's materials guide advises testing a sample when compatibility is in doubt (Graco, 2024).</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="bolted-or-clamped--13" class="scrollspy-head">Bolted or clamped</h3><a class="header-anchor" href="#bolted-or-clamped--13" title="Bolted or clamped" aria-label="Bolted or clamped"></a></div>

<p>Versamatic's 2020 <a href="https://www.versamatic.com/blog/aodd-pumps-for-mining-applications-explained" rel="noopener nofollow" target="_blank">guidance on mining pumps</a> describes clamped pumps as very simple to take apart with very few tools, with a manifold that can be removed on site, while bolted units take longer to strip down without pneumatic tools.</p>

<p>A bolted double diaphragm pump seals more easily than a clamped one, and the same guidance stresses that advantage when the pumped fluid is hazardous. On its <a href="https://www.psgdover.com/wilden/markets/packaging" rel="noopener nofollow" target="_blank">packaging-market page</a>, Wilden says the bolted configuration "offers the highest level of product containment" and ensures even pressure on the sealing faces.</p>

<p>Specify bolted for a hazardous liquid. Clamped earns its place where crews strip the pump on site often and the liquid allows it.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="ball-or-flap-valves-and-the-air-valve--14" class="scrollspy-head">Ball or flap valves, and the air valve</h3><a class="header-anchor" href="#ball-or-flap-valves-and-the-air-valve--14" title="Ball or flap valves, and the air valve" aria-label="Ball or flap valves, and the air valve"></a></div>

<p>Solids size decides the check-valve type. Yamada notes that most standard pumps carry four check balls (Yamada Pump, n.d.). Sandpiper builds its heavy-duty flap valve pumps for solids too large for ball valves; across the family's port sizes, it rates them for solids of 25 to 76 mm (1 to 3 in) (Sandpiper, n.d.).</p>

<p>On the air side, Yamada advertises a stall-free air valve (Yamada Pump, n.d.), and Graco advertises air valves that can be serviced externally (Graco, 2024). Both are manufacturer feature claims, so ask the supplier for the air-valve service procedure in the manual before counting either one in a comparison.</p>

<p>Shinjo describes its <a href="https://www.shinjopump.com/cast-iron-air-operated-double-diaphragm-pump-threaded-ends.html" rel="noopener" target="_blank">cast-iron QBY3 double diaphragm pump</a> as having "All-bolted construction with serviceable external air-valve assembly". That pairs the sealing advantage of a bolted housing with an air valve reached from outside the pump.</p>

<p>Housing, joints and valve type are chosen once, with the pump. The diaphragm is the part a double diaphragm pump owner keeps buying.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="work-with-us--15" class="scrollspy-head">Work with us</h3><a class="header-anchor" href="#work-with-us--15" title="Work with us" aria-label="Work with us"></a></div>

<p class="xr-cta-box"><strong>The liquid and the duty decide the build.</strong> Our Diaphragm Pumps range is quoted against a stated duty point, so send the flow, discharge pressure, fluid and pumping temperature with your inquiry, together with the liquid&rsquo;s character: solids, viscosity, abrasiveness and corrosiveness. With those on the page, the housing and diaphragm construction can be matched to the liquid rather than left open. <a href="https://www.shinjopump.com/diaphragm-pumps.html" rel="noopener" target="_blank">View the Diaphragm Pumps range</a></p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="the-diaphragm-pump-diaphragm-types-life-and-replacement--16" class="scrollspy-head">The diaphragm pump diaphragm: types, life and replacement</h2><a class="header-anchor" href="#the-diaphragm-pump-diaphragm-types-life-and-replacement--16" title="The diaphragm pump diaphragm: types, life and replacement" aria-label="The diaphragm pump diaphragm: types, life and replacement"></a></div>

<p>Diaphragms are the primary wear components in an air-operated double diaphragm pump (Eklund, 2026), and because both sit on one shaft, the pump flexes both of them on every stroke. A 2023 review of symmetrical diaphragm pumps in the journal Symmetry names the diaphragm and the one-way valve as the components most susceptible to erosion and damage by the transported materials (Zhao et al., 2023). Construction and duty decide how often they are replaced.</p>

<figure class="wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/diaphragm-pump-diaphragm-rubber-tpe-ptfe-types-1920_u8GOFb.webp%0A" alt="Rubber, TPE and PTFE pump diaphragms, the PTFE one with its backup, beside a used diaphragm with star-pattern cracks" style="max-width:100%;max-height:100%;" />
<figcaption>Diaphragms by construction: fabric-reinforced rubber, molded TPE, PTFE with its backup, and a used diaphragm with the star-pattern cracking that points to dry running.</figcaption>
</figure>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="rubber-tpe-and-ptfe-constructions--17" class="scrollspy-head">Rubber, TPE and PTFE constructions</h3><a class="header-anchor" href="#rubber-tpe-and-ptfe-constructions--17" title="Rubber, TPE and PTFE constructions" aria-label="Rubber, TPE and PTFE constructions"></a></div>

<p>Diaphragms for a double diaphragm pump come in three material families (Zuckett, 2024): rubber, thermoplastic elastomer (TPE) and polytetrafluoroethylene (PTFE). One-piece designs join the diaphragm and its plate.</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Construction</th>
			<th>How it is made</th>
			<th>What it trades</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Rubber</td>
			<td>Synthetic rubber with a nylon fabric mesh (Zuckett, 2024)</td>
			<td>The greatest temperature spans, per <a href="https://www.psgdover.com/wilden/products/diaphragms/diaphragm-materials/rubber-elastomers" rel="noopener nofollow" target="_blank">Wilden</a></td>
		</tr>
		<tr>
			<td>TPE</td>
			<td>Injection-molded, no fabric reinforcement (Zuckett, 2024)</td>
			<td>Santoprene (a TPE) shares the best flex life with neoprene (a rubber), per Versamatic (Caldwell, 2022); Geolast flexes more than fabric-reinforced Buna-N at lower cost, per <a href="https://www.processingmagazine.com/pumps-motors-drives/aodd-pumps/article/21164546/how-to-select-proper-diaphragm-materials" rel="noopener nofollow" target="_blank">All-Flo</a></td>
		</tr>
		<tr>
			<td>PTFE with backup</td>
			<td>Non-elastic PTFE over a backup diaphragm of another material, such as neoprene or Saniflex (Hytrel) (Zuckett, 2024)</td>
			<td>Best chemical resistance in Versamatic's list, but lower flex life and higher cost; abrasives in most cases rule it out (Caldwell, 2022)</td>
		</tr>
		<tr>
			<td>One-piece</td>
			<td>All-Flo single-piece, PTFE included, per the same All-Flo article; Wilden Chem-Fuse, no outer piston; Graco overmolded PTFE, no exposed plate (Graco, 2024)</td>
			<td>Chem-Fuse removes the outer-piston leak point, per Wilden; Graco rates overmolded PTFE at -10 to 82 &deg;C (14 to 180 &deg;F), standard PTFE at 4.4 to 100 &deg;C (40 to 212 &deg;F) (Graco, 2024)</td>
		</tr>
	</tbody>
</table></div>

<p>Wilden's reduced-stroke PTFE diaphragm cuts stroke and displacement to limit abrasive contact with the housing. Graco claims "3x longer diaphragm life" for overmolded PTFE against standard diaphragms (Graco, 2024), and Wilden's reliability page says Chem-Fuse extends diaphragm life "by up to 10-15x"; both are maker claims. Published limits disagree as well: Graco lists Hytrel to 65.6 &deg;C (150 &deg;F) (Graco, 2024) and Yamada to 120 &deg;C (248 &deg;F) (Yamada America, 2018), so check the quoted pump's own documentation. Shinjo's AODD guide tabulates elastomer temperatures. Converting between rubber or TPE and PTFE may need different center disks, shafts, backups, balls, seats and O-rings, per Yamada's <a href="https://www.yamadapump.com/is-ptfe-always-the-best-diaphragm-material/" rel="noopener nofollow" target="_blank">PTFE guidance</a>. Shinjo lists NBR, neoprene, EPDM, PTFE and FEP diaphragms for its <a href="https://www.shinjopump.com/double-diaphragm-pump-material-polypropylene-pp-pvdf-ptfe.html" rel="noopener" target="_blank">QBY3 double diaphragm pumps</a> and states that the allowable medium temperature depends on the pump body material and the diaphragm material, so a plastic-bodied pump can be limited by its housing before its diaphragm.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-shortens-diaphragm-life--18" class="scrollspy-head">What shortens diaphragm life</h3><a class="header-anchor" href="#what-shortens-diaphragm-life--18" title="What shortens diaphragm life" aria-label="What shortens diaphragm life"></a></div>

<p>For a double diaphragm pump, Yamada states that component life "is strongly influenced by the number and severity of operating cycles" (Eklund, 2026). Too much air pressure makes the pump cycle very rapidly, which Versamatic links to extra wear and premature failure; the pressure should leave the liquid time to fully enter and leave each chamber (Dill, 2022). Yamada adds that excessive inlet pressure or excessive suction lift can shorten diaphragm life (Yamada America, 2018). Sandpiper notes that flexibility typically suffers at lower temperatures and that maximum flex life cannot be expected at a material's temperature extremes (Ellis, 2021).</p>

<p>Abrasives tear. Versamatic's maintenance FAQs call paint an extremely abrasive fluid and expect a pump with neoprene or nitrile elastomers to break down within a relatively short time on it. All-Flo, announcing its <a href="https://empoweringpumps.com/all-flo-releases-diaphragm-pump-leak-sensor-technology-to-make-pumping-safer" rel="noopener nofollow" target="_blank">All-Safe DRM leak sensor</a>, calls diaphragm rupture rare and names large abrasives that tear the diaphragm as its most common cause. Hardware also loosens with creep and vibration; Sandpiper advises re-torquing to the manual with the pump not under pressure (Ellis, 2021).</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="reading-a-failed-diaphragm--19" class="scrollspy-head">Reading a failed diaphragm</h3><a class="header-anchor" href="#reading-a-failed-diaphragm--19" title="Reading a failed diaphragm" aria-label="Reading a failed diaphragm"></a></div>

<p>A used diaphragm records how a double diaphragm pump was run. Versamatic's troubleshooting guidance pairs patterns with likely causes:</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>What the diaphragm shows</th>
			<th>Likely cause</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Discoloration, cracking or bubbling around the edge</td>
			<td>Excessive heat or chemical attack (Versamatic, n.d.)</td>
		</tr>
		<tr>
			<td>Wear marks on one side</td>
			<td>Excessive suction-side pressure or an imploded air side; keep below 0.7 bar (10 psi) of NPSH (Versamatic, n.d.)</td>
		</tr>
		<tr>
			<td>Star-pattern cracking</td>
			<td>Dry running (Versamatic, n.d.)</td>
		</tr>
		<tr>
			<td>Outer diaphragm plate imprint</td>
			<td>Over-torquing (Versamatic, n.d.)</td>
		</tr>
		<tr>
			<td>Punctures</td>
			<td>A sharp item entered the pump; fit a suction screen (Versamatic, n.d.)</td>
		</tr>
		<tr>
			<td>Scratch marks on the air side</td>
			<td>High fluid inlet pressure, most often flooded suction (Versamatic, n.d.)</td>
		</tr>
		<tr>
			<td>Stretched center hole</td>
			<td>Outer plate torqued incorrectly, or high inlet pressure overstretching the diaphragm (Versamatic, n.d.)</td>
		</tr>
	</tbody>
</table></div>

<p>Photograph each failed diaphragm and file it with the stroke count. The pattern shows whether to change the material or the way the pump is run.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="detecting-a-rupture-before-the-air-side-does--20" class="scrollspy-head">Detecting a rupture before the air side does</h3><a class="header-anchor" href="#detecting-a-rupture-before-the-air-side-does--20" title="Detecting a rupture before the air side does" aria-label="Detecting a rupture before the air side does"></a></div>

<p>On a double diaphragm pump, product at the air exhaust is the obvious sign of a failed diaphragm (Versamatic, n.d.). When a diaphragm fails, the liquid can reach the air side. Versamatic warns that an incompatible air side can then cause problems in the main and pilot air valves and in other systems on the same air line, so it advises air-side materials that also suit the liquid (Caldwell, 2022).</p>

<p>Monitoring systems raise the alarm sooner:</p>

<ul>
	<li>Wilden's Wil-Gard III places sensors between the PTFE primary diaphragm and the back-up diaphragm and reacts to conductive fluids, with a stated sensitivity of 75 microsiemens.</li>
	<li>All-Flo's All-Safe DRM puts an early-warning sensor between the PTFE overlay and the backup, plus a second sensor in the air section.</li>
	<li>Yamada's DM-2 can cut the air supply and can trigger a whistle or alarm when it detects a diaphragm leak.</li>
</ul>

<p>A conductivity sensor may miss a non-conductive solvent, so confirm the sensing principle suits the liquid.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="setting-a-replacement-interval--21" class="scrollspy-head">Setting a replacement interval</h3><a class="header-anchor" href="#setting-a-replacement-interval--21" title="Setting a replacement interval" aria-label="Setting a replacement interval"></a></div>

<p>Versamatic states that "there is no standard AODD pump maintenance schedule" (Dill, 2022). A stroke figure from another plant is a poor guide, since Yamada ties component life to the severity of operating cycles as well as their number (Eklund, 2026). The interval for a double diaphragm pump has to be learned on its own duty. Versamatic calls a stroke counter "a good way to keep track of approximately how many strokes you can expect before a diaphragm needs to be replaced" (Dill, 2022). Wilden's PCMI cycle monitor counts complete cycles from a magnet on the air-valve spool. When a diaphragm or another part has to be replaced, Versamatic advises replacing all the components at the same time, while the pump is out of service (Versamatic, n.d.).</p>

<blockquote class="callout callout-tip">
<p><strong>Tip:</strong> Log the stroke count and failure pattern at every diaphragm change. Plan the next change below the shortest life seen on that duty, and re-baseline after any change of fluid, temperature, air pressure or diaphragm material.</p>
</blockquote>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="wet-kits-and-air-kits--22" class="scrollspy-head">Wet kits and air kits</h3><a class="header-anchor" href="#wet-kits-and-air-kits--22" title="Wet kits and air kits" aria-label="Wet kits and air kits"></a></div>

<p>Repair kits split a double diaphragm pump into a wet side and an air side. Wilden's <a href="https://wilden-pumps.co.uk/sites/default/files/docs/AP-Wilden-Parts-Kit-Flyer.pdf" rel="noopener nofollow" target="_blank">parts kit flyer</a> says its Wet Kit "includes only elastomers located on the wet side of the pump such as diaphragms, balls, seats, gaskets and o-rings (if required)" and that no air-side parts are included. Its Air Kit includes the air-valve spool. Sandpiper offers its wear parts (diaphragms, balls, seats and flaps) in kit form, and individual wear parts on both the wet and air sides. A US distributor's <a href="https://pumpcatalog.com/blog/aodd-diaphragm-pump-repair-kits-guide" rel="noopener nofollow" target="_blank">repair kit guide</a> notes that a Wilden kit is coded to the pump configuration read from the model nameplate, and that a pump with integral piston diaphragms takes a different wet kit. Ask for kit part numbers that match the configuration quoted.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="air-operated-or-electric-double-diaphragm-pump--23" class="scrollspy-head">Air-operated or electric double diaphragm pump</h2><a class="header-anchor" href="#air-operated-or-electric-double-diaphragm-pump--23" title="Air-operated or electric double diaphragm pump" aria-label="Air-operated or electric double diaphragm pump"></a></div>

<p>The drive sets what a double diaphragm pump costs to run. Air-operated pumps run on plant compressed air; electric ones drive the same diaphragms from a motor.</p>

<figure class="wp-block-image"><img src="https:///www/wwwroot/jeawinadmin/public_html/resource/upfiles/161/images/news/261018/electric-double-diaphragm-pump-motor-gearbox_xvysqn.webp" alt="Electric double diaphragm pump with motor and gearbox on a plant floor, fed by a single power cable" loading="lazy"  class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Electric double diaphragm pump with motor and gearbox on a plant floor, fed by a single power cable' loading='lazy'  />
<figcaption>An electric double diaphragm pump: a motor and gearbox drive the diaphragms, and a power cable takes the place of the compressed-air line.</figcaption>
</figure>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Factor</th>
			<th>Air-operated</th>
			<th>Electric (motor-driven)</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Energy source</td>
			<td>Plant compressed air</td>
			<td>Site electrical supply</td>
		</tr>
		<tr>
			<td>Energy efficiency</td>
			<td>Low; runs on costly compressed air (U.S. Department of Energy, 2003)</td>
			<td>Higher, per Graco (Graco, n.d.)</td>
		</tr>
		<tr>
			<td>Hazardous areas</td>
			<td>No motor; ground it for flammable liquids (Caldwell, 2022)</td>
			<td>Explosion-proof motor for flammable liquids (Shinjo's DBY instruction)</td>
		</tr>
		<tr>
			<td>Dry running</td>
			<td>Tolerated; sustained dry running wears the diaphragm and wastes air (Eklund, 2026) (U.S. Department of Energy, 2003)</td>
			<td>Model-specific</td>
		</tr>
		<tr>
			<td>Controls</td>
			<td>Regulator set to the maximum head required; flow control valve sets speed (U.S. Department of Energy, 2003)</td>
			<td>Motor matched to phase, voltage and frequency</td>
		</tr>
		<tr>
			<td>Initial vs running cost</td>
			<td>Can cost less to buy; typically more to maintain (Graco, n.d.)</td>
			<td>Lower lifetime cost, per Graco (Graco, n.d.)</td>
		</tr>
	</tbody>
</table></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-compressed-air-costs--24" class="scrollspy-head">What compressed air costs</h3><a class="header-anchor" href="#what-compressed-air-costs--24" title="What compressed air costs" aria-label="What compressed air costs"></a></div>

<p>The US Department of Energy's 2003 compressed air sourcebook calls compressed air probably the most expensive form of energy in a plant, with a typical overall efficiency of 10 to 15 percent (U.S. Department of Energy, 2003). It lists diaphragm pumps among potentially inappropriate uses (U.S. Department of Energy, 2003) and notes they are commonly installed without regulators or with regulators set higher than necessary (U.S. Department of Energy, 2003).</p>

<p>The efficiency figure covers compressed air systems in general, not one pump. At pump level, Versamatic writes that "operating AODD pumps costs more than purchasing them" (Dill, 2022), and its <a href="https://www.versamatic.com/blog/what-is-the-average-life-cycle-cost-of-an-aodd-pump" rel="noopener nofollow" target="_blank">life-cycle cost article</a> puts the purchase price at 5 to 20 percent of total cost of ownership. Shinjo's <a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html" rel="noopener" target="_blank">AODD sizing and air-use guide</a> converts air demand into kilowatts and running cost.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="when-the-electric-version-wins--25" class="scrollspy-head">When the electric version wins</h3><a class="header-anchor" href="#when-the-electric-version-wins--25" title="When the electric version wins" aria-label="When the electric version wins"></a></div>

<p>Graco claims its electric double diaphragm pump cuts energy consumption "up to 5x" against an air-operated one (Graco, n.d.), and that one of its electric pumps can reduce energy usage and costs "by up to 80%" (Graco, n.d.). A fivefold cut is an 80% saving, so the two figures are one vendor claim; "up to" marks the best case. Shinjo offers its <a href="https://www.shinjopump.com/dby-motor-driven-diaphragm-pump-flow-capacity-0-5-16-m3-h.html" rel="noopener" target="_blank">DBY motor-driven pump</a> where plant air is unavailable.</p>

<p>Graco's electric range covers 25 to 50 mm (1 to 2 in) ports, against 6 to 76 mm (1/4 to 3 in) for its air-operated pumps (Graco, 2024). The motor must match the site supply: ARO offers its three-chamber <a href="https://www.arozone.com/en/technologies/electric-diaphragm-pumps-overview" rel="noopener nofollow" target="_blank">EVO 300</a> for 3-phase 50/60 Hz at 200-240 V, 380-500 V or 525-600 V. Shinjo requires an explosion-proof motor on the DBY for flammable liquids; that is an installation instruction, and the quote should still name the pump's hazardous-area rating.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="dry-running-is-model-specific--26" class="scrollspy-head">Dry running is model-specific</h3><a class="header-anchor" href="#dry-running-is-model-specific--26" title="Dry running is model-specific" aria-label="Dry running is model-specific"></a></div>

<p>Air-operated pumps tolerate dry running because they use no close tolerances; Yamada calls the capability a feature, not an operating strategy (Eklund, 2026). Running empty, a pump "will rapid cycle, wearing out the diaphragm and wasting air", per the US DOE sourcebook (U.S. Department of Energy, 2003).</p>

<p>Electric double diaphragm pumps differ by model. Sandpiper's electric pump guide says an EODD pump "can function safely even when the fluid source runs dry" and ARO's <a href="https://www.arozone.com/en/technologies/electric-diaphragm-pumps-overview" rel="noopener nofollow" target="_blank">electric pump overview</a> lists run-dry capability, while Shinjo states its DBY is "strictly forbidden to run dry". Ask the quote to state the dry-running limit for the exact double diaphragm pump offered.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="running-practices-that-decide-diaphragm-life--27" class="scrollspy-head">Running practices that decide diaphragm life</h2><a class="header-anchor" href="#running-practices-that-decide-diaphragm-life--27" title="Running practices that decide diaphragm life" aria-label="Running practices that decide diaphragm life"></a></div>

<p>Yamada states that the life of a double diaphragm pump's components is strongly influenced by the number and severity of its operating cycles (Eklund, 2026), and its 2018 product guide adds that excessive inlet pressure or excessive suction lift can shorten diaphragm life (Yamada America, 2018). Air pressure, stroke rate and inlet conditions are set on site, after the pump is bought.</p>

<ul>
	<li><strong>Set the air regulator to the duty.</strong> The US Department of Energy's compressed-air sourcebook says "the regulator should be adjusted to equal the maximum head that the pump is required to provide" (U.S. Department of Energy, 2003). Check the setting again whenever the discharge line changes.</li>
	<li><strong>Fit speed control.</strong> On a double diaphragm pump, a flow control valve upstream of the regulator gives speed control, per the sourcebook (U.S. Department of Energy, 2003). Fewer strokes per minute mean fewer flex cycles.</li>
	<li><strong>Hold inlet pressure down.</strong> Versamatic advises keeping suction-side pressure below 0.7 bar (10 psi) of NPSH (Versamatic, n.d.). Measure inlet pressure on a flooded suction before start-up, and keep suction lift inside the datasheet figure.</li>
	<li><strong>Screen the suction.</strong> Versamatic traces diaphragm punctures to sharp items entering the pump and advises fitting a suction screen (Versamatic, n.d.). Clean it on a schedule; a clogged screen starves the inlet.</li>
	<li><strong>Limit dry running.</strong> An air-operated double diaphragm pump tolerates dry running because it uses no close tolerances, Yamada explains, yet a dry pump cycles faster, uses more air and adds diaphragm fatigue without moving liquid (Eklund, 2026). Versamatic warns that prolonged dry running weakens the diaphragm and recommends a pneumatic liquid level controller (Versamatic, n.d.); Verder's <a href="https://www.verderliquids.com/int/en/downloads/whitepapers-and-brochures/10-ways-to-kill-your-diaphragm-pump" rel="noopener nofollow" target="_blank">guide to diaphragm pump failures</a> describes a flow stop valve that cuts the air when air consumption rises.</li>
	<li><strong>Re-torque with the pump depressurized.</strong> Sandpiper notes that housing hardware loosens through material creep, vibration in transit and temperature changes, and advises re-torquing to the manual with the pump not under pressure (Ellis, 2021). Transit vibration makes installation the first check.</li>
	<li><strong>Match the air side to the liquid.</strong> A failed diaphragm can let liquid reach the air side, so Versamatic advises air-side materials that also suit the liquid (Caldwell, 2022).</li>
</ul>

<p>Pulsation dampeners and grounding belong to the same installation; Shinjo's pneumatic diaphragm pump guide covers pulsation and static grounding for air-operated double diaphragm pumps.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="reading-a-quote-for-a-double-diaphragm-pump--28" class="scrollspy-head">Reading a quote for a double diaphragm pump</h2><a class="header-anchor" href="#reading-a-quote-for-a-double-diaphragm-pump--28" title="Reading a quote for a double diaphragm pump" aria-label="Reading a quote for a double diaphragm pump"></a></div>

<p>A quote records the pump a supplier will build. Before you compare a <a href="https://www.shinjopump.com/diaphragm-pumps.html" rel="noopener" target="_blank">diaphragm pump for sale</a> from two suppliers, check that both quotes answer the same duty questions and name the same parts.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-the-quote-must-state--29" class="scrollspy-head">What the quote must state</h3><a class="header-anchor" href="#what-the-quote-must-state--29" title="What the quote must state" aria-label="What the quote must state"></a></div>

<p>Graco and Yamada each publish the data they ask for before specifying a pump (Graco, 2024) (Yamada America, 2018). A complete quote for a double diaphragm pump restates the duty it was sized for and commits to the build:</p>

<ol>
	<li>The liquid: solids, pH, viscosity, specific gravity, abrasiveness and corrosiveness.</li>
	<li>Pumping temperature, required flow rate and operating condition.</li>
	<li>Feed tank position, suction line length and vertical rise.</li>
	<li>Discharge distance and discharge pressure or <a href="https://www.shinjopump.com/news/what-is-pump-head-and-total-head-total-dynamic-head.html" rel="noopener" target="_blank">total dynamic head</a>.</li>
	<li>Hose diameters and other installation requirements.</li>
	<li>Available air supply; our AODD sizing guide lists the air-side fields.</li>
	<li>Materials by part: housings, diaphragms, check balls, seals and connecting rod.</li>
	<li>Certifications, production tests and whether a witnessed lab test is required.</li>
</ol>

<p>Sandpiper's RFQ data sheet for its gas-operated G15 pump lists a 100% leak test of gas-containing housings, a hydrostatic test of pressure parts except the diaphragms at five times the maximum rated operating pressure, and static dissipation not exceeding 1 megaohm between the grounding connection and each metal component. A quote that only says "tested" cannot be checked.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-drives-the-price--30" class="scrollspy-head">What drives the price</h3><a class="header-anchor" href="#what-drives-the-price--30" title="What drives the price" aria-label="What drives the price"></a></div>

<p>Price for a double diaphragm pump follows the build: port size, housing material, diaphragm construction, valve type, drive (air or electric), accessories (pulsation dampener, leak detection) and the documents and tests ordered. Versamatic names PTFE and Viton the most expensive diaphragm materials (Caldwell, 2022), and Graco states that an air-operated pump can cost less to buy than an electric diaphragm pump (Graco, n.d.). Witnessed tests and material certificates are priced items too, so compare quotes line by line, never by the total.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="interchangeable-parts-ask-do-not-assume--31" class="scrollspy-head">Interchangeable parts: ask, do not assume</h3><a class="header-anchor" href="#interchangeable-parts-ask-do-not-assume--31" title="Interchangeable parts: ask, do not assume" aria-label="Interchangeable parts: ask, do not assume"></a></div>

<p>All-Flo states that its mounting feet and liquid porting location are "designed to match competitors' footprint" (All-Flo, n.d.). That claim covers bolts and pipes only. Wet-end parts are a separate question. Even within one pump, Yamada's PTFE guidance warns that converting between rubber or TPE and PTFE diaphragms can need different center disks, shafts, backup diaphragms, balls, seats and O-rings. Wilden's <a href="https://wilden-pumps.co.uk/sites/default/files/docs/AP-Wilden-Parts-Kit-Flyer.pdf" rel="noopener nofollow" target="_blank">kit flyer</a> codes its repair kits by pump size, configuration, material and air distribution system.</p>

<p>When a double diaphragm pump replaces an existing one, have the quote name the model and part numbers it claims to match, then check them against a dimensioned drawing.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="how-to-evaluate-diaphragm-pump-suppliers--32" class="scrollspy-head">How to evaluate diaphragm pump suppliers</h2><a class="header-anchor" href="#how-to-evaluate-diaphragm-pump-suppliers--32" title="How to evaluate diaphragm pump suppliers" aria-label="How to evaluate diaphragm pump suppliers"></a></div>

<p>Judge a supplier by the documents it can produce before the order: a factory that builds the double diaphragm pump holds them, and a reseller has to ask for them.</p>

<figure class="wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/diaphragm-pump-suppliers-performance-test-bench-r2-1920_LlGJ3V.webp" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/852a40e6f02d492f72969497f064e22a/diaphragm-pump-suppliers-performance-test-bench-r2-1920_LlGJ3V-320x214.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/852a40e6f02d492f72969497f064e22a/diaphragm-pump-suppliers-performance-test-bench-r2-1920_LlGJ3V-640x428.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/852a40e6f02d492f72969497f064e22a/diaphragm-pump-suppliers-performance-test-bench-r2-1920_LlGJ3V-800x535.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/852a40e6f02d492f72969497f064e22a/diaphragm-pump-suppliers-performance-test-bench-r2-1920_LlGJ3V-1024x684.webp 1024w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/852a40e6f02d492f72969497f064e22a/diaphragm-pump-suppliers-performance-test-bench-r2-1920_LlGJ3V-1280x855.webp 1280w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/852a40e6f02d492f72969497f064e22a/diaphragm-pump-suppliers-performance-test-bench-r2-1920_LlGJ3V-1600x1069.webp 1600w,https://img.jeawincdn.com/resource/upfiles/161/images/news/261018/resize/852a40e6f02d492f72969497f064e22a/diaphragm-pump-suppliers-performance-test-bench-r2-1920_LlGJ3V-1920x1283.webp 1920w" width="1920" height="1283"  
      alt="Diaphragm pump on a supplier's test bench with suction and discharge gauges, a flow meter and a test record clipboard" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Diaphragm pump on a supplier's test bench with suction and discharge gauges, a flow meter and a test record clipboard' loading='lazy'  sizes="(max-width: 1920px) 96vw, 1920px"  />
<figcaption>A pump on a performance test bench: gauges on the suction and discharge lines, a flow meter, and a clipboard to record each test point.</figcaption>
</figure>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="evidence-that-separates-a-maker-from-a-trader--33" class="scrollspy-head">Evidence that separates a maker from a trader</h3><a class="header-anchor" href="#evidence-that-separates-a-maker-from-a-trader--33" title="Evidence that separates a maker from a trader" aria-label="Evidence that separates a maker from a trader"></a></div>

<p>A maker designs and tests the pump. An assembler builds it from bought-in major parts. A trader resells it. Ask for this evidence on the exact double diaphragm pump quoted:</p>

<ol>
	<li>The supplier's own performance curve and test record for that model.</li>
	<li>Material certificates for wetted parts, stating the EN 10204 type.</li>
	<li>A spare-parts list with part numbers, wet side and air side.</li>
	<li>A sectional drawing and a dimensioned drawing.</li>
	<li>An installation, operation and service manual.</li>
	<li>The number and issuer of any management-system certificate it names.</li>
</ol>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="tests-and-material-certificates--34" class="scrollspy-head">Tests and material certificates</h3><a class="header-anchor" href="#tests-and-material-certificates--34" title="Tests and material certificates" aria-label="Tests and material certificates"></a></div>

<p><a href="https://www.pumps.org/product/ansi-hi-10-6-air-operated-pump-tests/" rel="noopener nofollow" target="_blank">ANSI/HI 10.6 Air-Operated Pump Tests</a>, the Hydraulic Institute standard current in its 2021 edition, sets uniform procedures for mechanical integrity in operation, performance, NPSH/NPIP, suction lift, hydrostatic and noise testing of air-operated diaphragm and bellows pumps. Two makers' double diaphragm pump curves tested to it can be compared on one basis.</p>

<p><a href="https://www.pumps.org/product/ansi-hi-10-1-10-5-air-operated-pumps-for-nomenclature-definitions-application-and-operation/" rel="noopener nofollow" target="_blank">ANSI/HI 10.1-10.5</a>, current in its 2021 edition, covers nomenclature, definitions, application and operation. When HI <a href="https://www.csemag.com/hydraulic-institute-releases-air-operated-pump-and-test-standards" rel="noopener nofollow" target="_blank">released the 2004 editions</a>, it said the 10.6 tests are based on water at ambient temperature unless otherwise noted. Ask which test liquid and temperature the supplier's curve used.</p>

<p>Under <a href="https://www.penflex.com/news/bs-en-10204-2004-products-types-inspection-documents" rel="noopener nofollow" target="_blank">EN 10204</a>, each inspection document type certifies something different:</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>EN 10204 type</th>
			<th>What the document is</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>2.1</td>
			<td>The manufacturer's statement of compliance with the order</td>
		</tr>
		<tr>
			<td>2.2</td>
			<td>Adds the results of non-specific inspection</td>
		</tr>
		<tr>
			<td>3.1</td>
			<td>Reports the results of specific inspection; validated by the manufacturer's authorized inspection representative, independent of the manufacturing department</td>
		</tr>
		<tr>
			<td>3.2</td>
			<td>Validated by the manufacturer's authorized inspection representative together with the purchaser's authorized inspection representative or an inspector designated by official regulations</td>
		</tr>
	</tbody>
</table></div>

<p>Name the type in the order.</p>

<p>Search <a href="https://www.iafcertsearch.org/standards/iso-9001-quality-management-systems-qms" rel="noopener nofollow" target="_blank">IAF CertSearch's ISO 9001 register</a> by company, certificate number or certification body to see whether a certificate is active, suspended or withdrawn. The same page notes that ISO 9001 clause 8.4 requires control of external providers, so a certified organization must evaluate, select and monitor its suppliers. Ask a certified supplier how it does so.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="spare-parts-for-the-life-of-the-pump--35" class="scrollspy-head">Spare parts for the life of the pump</h3><a class="header-anchor" href="#spare-parts-for-the-life-of-the-pump--35" title="Spare parts for the life of the pump" aria-label="Spare parts for the life of the pump"></a></div>

<p>A double diaphragm pump needs new diaphragms for as long as it runs. A <a href="https://www.pumpsandsystems.com/article/how-identify-avoid-counterfeit-aodd-pump-parts" rel="noopener nofollow" target="_blank">Pumps &amp; Systems article on counterfeit AODD parts</a> describes the warning signs: look-alike part numbers with an added prefix, missing manufacturing date stamps and parts shipped in unbranded bags. Fitting them can void the warranty, reduce flow, cause more breakdowns and compromise chemical compatibility. Buy diaphragms from a verified supplier or one the pump maker recommends (Zuckett, 2024). Before ordering, get in writing who will supply the pump's diaphragm kits.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="frequently-asked-questions--36" class="scrollspy-head">Frequently Asked Questions</h2><a class="header-anchor" href="#frequently-asked-questions--36" title="Frequently Asked Questions" aria-label="Frequently Asked Questions"></a></div>

<p><strong>What is a double diaphragm pump?</strong></p>

<p>A double diaphragm pump is a positive-displacement pump with two diaphragms on one shared shaft, so one chamber discharges while the other fills (Yamada Pump, n.d.). Compressed air drives the AODD version and an electric motor drives the EODD version (Graco, n.d.). The same machines are also sold as dual diaphragm pumps.</p>

<p><strong>What is the main difference between a single diaphragm pump and a double diaphragm pump?</strong></p>

<p>The double design has two chambers on one shaft and discharges on every stroke, two discharges per cycle (Versamatic, n.d.). The Hydraulic Institute describes both simplex and duplex air-operated pumps, and notes that a simplex pump discharges no liquid during its recharge stroke. Writing about electric pumps, Sandpiper says single diaphragm pumps typically serve lower flow rates and pressures.</p>

<p><strong>What are the disadvantages of a diaphragm pump?</strong></p>

<p>Air-operated models use compressed air: the US DOE calls it probably the most expensive form of energy in a plant (U.S. Department of Energy, 2003), at 10 to 15 percent typical overall efficiency (U.S. Department of Energy, 2003). A 2023 review in Symmetry names the diaphragm and one-way valve as the parts most susceptible to erosion and damage (Zhao et al., 2023). The flow also pulses, which is why Versamatic recommends a surge suppressor where steadier pressure is needed (Versamatic, n.d.).</p>

<p><strong>Can a double diaphragm pump run dry?</strong></p>

<p>Air-operated models tolerate dry running: they use no close tolerances and do not depend on the pumped liquid for lubrication or cooling (Eklund, 2026). Sustained dry running still wastes compressed air and adds diaphragm fatigue and wear on other internal parts, because the empty pump cycles faster (Eklund, 2026). Shinjo permits short-time dry running on its QBY3 but forbids it on its electric DBY.</p>

<p><strong>Do pump diaphragms need to be replaced?</strong></p>

<p>Yes. Versamatic states there is no standard AODD pump maintenance schedule and advises keeping notes on how each pump responds (Dill, 2022). A stroke counter tracks roughly how many strokes a diaphragm lasts before it needs replacing (Dill, 2022). When a part has to be replaced, Versamatic advises replacing all the components at the same time (Versamatic, n.d.).</p>

<p><strong>What is the maximum flow rate of a 1 inch diaphragm pump?</strong></p>

<p>Ball-valve 25 mm (1 in) models from All-Flo, Yamada and ARO top out at 155.8 to 182 L/min (41 to 48 US gpm), on water at maximum air pressure and open discharge (All-Flo, n.d.; ARO, n.d.; Yamada Pump, n.d.). Sandpiper rates its same-size flap-valve HDF1 to 265 L/min (70 US gpm) (Sandpiper, n.d.). These are ceilings, so size up one port size (Versamatic, n.d.).</p>

<p><strong>Are diaphragm pumps positive displacement?</strong></p>

<p>Yes. The Hydraulic Institute's ANSI/HI 10.1-10.5 covers air-operated pumps as positive-displacement reciprocating pumps driven by compressed gas. Flow equals strokes per minute times the volume each stroke displaces (Versamatic, n.d.). That displacement changes with the diaphragm material: Yamada publishes separate rubber and PTFE performance curves (Yamada America, 2018).</p>

<p><strong>How much does a diaphragm pump cost?</strong></p>

<p>Price follows the specification: port size, housing and diaphragm materials, drive, and the tests and certificates ordered. Versamatic ranks PTFE and Viton the most expensive diaphragm materials (Caldwell, 2022). Graco says air-operated pumps can cost less to buy than electric ones (Graco, n.d.). Versamatic notes that operating an AODD pump costs more than buying it (Dill, 2022).</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="conclusion--37" class="scrollspy-head">Conclusion</h2><a class="header-anchor" href="#conclusion--37" title="Conclusion" aria-label="Conclusion"></a></div>

<p>What a double diaphragm pump costs to keep, diaphragms included, is decided before the order is placed.</p>

<p>Size for the duty. A catalog flow figure is one model's maximum on water at maximum air pressure, so match the pump to the flow and head the process needs. Go up one port size: fewer strokes for the same volume mean fewer flex cycles on each diaphragm.</p>

<p>Let the liquid choose the housing and the diaphragm. Rubber, TPE and PTFE each trade flex life against chemical range at a different cost; check the choice in a compatibility source. No universal replacement interval exists, so count strokes and read each failed diaphragm for its cause.</p>

<p>Choose air or electric drive on what compressed air costs the plant and on the maker's dry-running statement for that model. Hold the quote to materials by part, the diaphragm grade, the test standard and a spares list, and ask whether parts interchange. Judge the supplier on test reports and material certificates you can check.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="references--38" class="scrollspy-head">References</h2><a class="header-anchor" href="#references--38" title="References" aria-label="References"></a></div>

<ol>
	<li>Versamatic. (n.d.). The Versamatic AODD pump troubleshooting guide. Retrieved October 15, 2026, from <a href="https://www.versamatic.com/resources/aodd-pump-troubleshooting-guide-pillar-page" rel="noopener nofollow" target="_blank">https://www.versamatic.com/resources/aodd-pump-troubleshooting-guide-pillar-page</a></li>
	<li>Caldwell, T. (2022, February 1). Air-operated double-diaphragm (AODD) pump materials selection. Versamatic. <a href="https://www.versamatic.com/blog/aodd-pump-materials-what-to-use-and-why" rel="noopener nofollow" target="_blank">https://www.versamatic.com/blog/aodd-pump-materials-what-to-use-and-why</a></li>
	<li>Dill, J. (2022, April 1). How AODD pump preventative maintenance helps you avoid failure. Versamatic. <a href="https://www.versamatic.com/blog/how-to-maintain-your-aodd-pump-to-avoid-failure" rel="noopener nofollow" target="_blank">https://www.versamatic.com/blog/how-to-maintain-your-aodd-pump-to-avoid-failure</a></li>
	<li>Yamada Pump. (n.d.). Yamada diaphragm pump NDP series. Retrieved October 15, 2026, from <a href="https://www.yamadapump.com/products" rel="noopener nofollow" target="_blank">https://www.yamadapump.com/products</a></li>
	<li>Yamada America. (2018). Yamada product guide [Product catalog]. <a href="https://www.yamadapump.com/assets/literature/guides/Yamada_2018_US-ENG_Product_Guide.pdf" rel="noopener nofollow" target="_blank">https://www.yamadapump.com/assets/literature/guides/Yamada_2018_US-ENG_Product_Guide.pdf</a></li>
	<li>Eklund, R. (2026, September 1). Can an AODD pump run dry? Understanding the costs of dry running. Yamada Pump. <a href="https://www.yamadapump.com/blog/can-an-aodd-pump-run-dry-understanding-the-costs-of-dry-running" rel="noopener nofollow" target="_blank">https://www.yamadapump.com/blog/can-an-aodd-pump-run-dry-understanding-the-costs-of-dry-running</a></li>
	<li>All-Flo. (n.d.). Air operated double diaphragm pumps: Product catalog. PSG. Retrieved October 15, 2026, from <a href="https://www.psgdover.com/docs/default-source/all-flo-docs/brochures/all-flo-product-catalog.pdf?sfvrsn=16d2da38_16" rel="noopener nofollow" target="_blank">https://www.psgdover.com/docs/default-source/all-flo-docs/brochures/all-flo-product-catalog.pdf?sfvrsn=16d2da38_16</a></li>
	<li>ARO. (n.d.). What is the maximum capacity of AODD pump? Ingersoll Rand. Retrieved October 15, 2026, from <a href="https://www.arozone.com/en/tools/blog/what-is-the-maximum-capacity-of-aodd-pump" rel="noopener nofollow" target="_blank">https://www.arozone.com/en/tools/blog/what-is-the-maximum-capacity-of-aodd-pump</a></li>
	<li>Sandpiper. (n.d.). Heavy duty flap pumps, metallic &amp; non-metallic. Retrieved October 15, 2026, from <a href="https://www.sandpiperpump.com/pumps/heavy-duty-flap" rel="noopener nofollow" target="_blank">https://www.sandpiperpump.com/pumps/heavy-duty-flap</a></li>
	<li>Ellis, T. (2021, June 4). The 5 most common AODD pumping mistakes and how to avoid them. Sandpiper. <a href="https://www.sandpiperpump.com/blog/most-common-aodd-pumping-mistakes" rel="noopener nofollow" target="_blank">https://www.sandpiperpump.com/blog/most-common-aodd-pumping-mistakes</a></li>
	<li>Graco. (2024). Materials of construction guide (Form No. 345089, Rev. D). <a href="https://www.graco.com/content/dam/graco/com_documents/345/345089/345089EN-D.pdf" rel="noopener nofollow" target="_blank">https://www.graco.com/content/dam/graco/com_documents/345/345089/345089EN-D.pdf</a></li>
	<li>Graco. (n.d.). How does a diaphragm pump work and what is it used for? Retrieved October 15, 2026, from <a href="https://www.graco.com/us/en/in-plant-manufacturing/solutions/articles/benefits-of-an-electric-diaphragm-pump.html" rel="noopener nofollow" target="_blank">https://www.graco.com/us/en/in-plant-manufacturing/solutions/articles/benefits-of-an-electric-diaphragm-pump.html</a></li>
	<li>U.S. Department of Energy. (2003). Improving compressed air system performance: A sourcebook for industry (2nd ed., DOE/GO-102003-1822). Compressed Air Challenge. <a href="https://www1.eere.energy.gov/manufacturing/tech_assistance/pdfs/compressed_air_sourcebook.pdf" rel="noopener nofollow" target="_blank">https://www1.eere.energy.gov/manufacturing/tech_assistance/pdfs/compressed_air_sourcebook.pdf</a></li>
	<li>Zhao, K., Lou, Y., Peng, G., Liu, C., &amp; Chang, H. (2023). A review of the development and research status of symmetrical diaphragm pumps. Symmetry, 15(11), Article 2091. <a href="https://doi.org/10.3390/sym15112091" rel="noopener nofollow" target="_blank">https://doi.org/10.3390/sym15112091</a></li>
	<li>Zuckett, T. (2024, April 10). How to select the most efficient diaphragm for an AODD pump. Processing. <a href="https://www.processingmagazine.com/pumps-motors-drives/aodd-pumps/article/55016664/how-to-select-the-most-efficient-diaphragm-for-an-aodd-pump" rel="noopener nofollow" target="_blank">https://www.processingmagazine.com/pumps-motors-drives/aodd-pumps/article/55016664/how-to-select-the-most-efficient-diaphragm-for-an-aodd-pump</a></li>
</ol>

<hr>
<p class="article-signature"><em>Last reviewed and updated: October 2026. Author: Shinjo Pump engineering team. For pump selection support or a quotation on your duty point, <a href="https://www.shinjopump.com/contact.html" rel="noopener" target="_blank">contact our team</a>.</em></p>
</div></div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>Multistage Pump Selection: Head, Stages, NPSH and Pressure</title>
      <description><![CDATA[Multistage pump selection step by step: total head, number of stages using real DF pump data, NPSH, casing pressure and minimum flow.]]></description>
      <pubDate>Sun, 11 Oct 2026 11:56:15 +0000</pubDate>
      <link>https://www.shinjopump.com/news/multistage-pump-selection.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/multistage-pump-selection.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content">
<div class="sj-article">
<p class="sj-lead">Multistage pump selection comes down to five numbers: the flow, the total head, the head each stage adds at that flow, the NPSH available at the first stage, and the highest pressure the casing will see. Divide the required head by the stage head to get the number of stages. Then check three things: the pump runs near its best efficiency point, the first stage will not cavitate, and suction pressure plus shut-off head stays within the casing rating. Shinjo&#39;s <a href="https://www.shinjopump.com/cast-steel-multistage-pump-single-suction-15-336-m3-h.html">DF multistage pump</a> covers 15&ndash;336 m&sup3;/h and 144&ndash;690 m. For very small flows at high head, a partial emission pump is often the better fit.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="step-1-define-the-flow-cases--0">Step 1: Define the Flow Cases</h2><a class="header-anchor" href="#step-1-define-the-flow-cases--0" title="Step 1: Define the Flow Cases" aria-label="Step 1: Define the Flow Cases"></a></div>

<p>State the minimum, normal and maximum flow, and how long the pump runs at each. If two pumps share a header, work out the real combined demand rather than adding up the maximum of every user. Say whether a standby pump must carry the full duty alone.</p>

<p>Record the liquid&#39;s temperature, density, viscosity and vapor pressure as well. Water-based pump curves do not apply directly to viscous oils, and abrasive solids rule out most multistage pumps, which have close running clearances.</p>

<p>Do not add a margin to every number. A safety factor on flow, another on friction losses and a third on head lead to a pump that spends its life throttled, far from its best efficiency point.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="step-2-calculate-the-total-head--1">Step 2: Calculate the Total Head</h2><a class="header-anchor" href="#step-2-calculate-the-total-head--1" title="Step 2: Calculate the Total Head" aria-label="Step 2: Calculate the Total Head"></a></div>

<p>For a pump moving liquid between two vessels, the required head is:</p>

<p class="sj-formula">H = &Delta;z + &Delta;p &divide; (&rho; &times; g) + h<sub>L</sub></p>

<p>&Delta;z is the elevation difference, &Delta;p the pressure difference between the vessels, &rho; the liquid density, g gravity and h<sub>L</sub> the friction loss in pipes, fittings, valves and equipment. For large tanks, the velocity difference is negligible.</p>

<p>Example: water at 20 &deg;C is pumped from an open tank to a vessel at 2.2 MPa gauge, 25 m higher, with 20 m of friction loss at 28 m&sup3;/h:</p>

<p class="sj-formula">H = 25 + 2,200,000 &divide; (998 &times; 9.81) + 20 &asymp; 25 + 224.7 + 20 &asymp; 270 m</p>

<p>Two common mistakes: adding the discharge pressure again when it is already counted in &Delta;p, and forgetting to subtract the pressure in a pressurized suction vessel. For more on the terms, see <a href="https://www.shinjopump.com/news/what-is-pump-head-and-total-head-total-dynamic-head.html">total head and total dynamic head</a> and <a href="https://www.shinjopump.com/news/what-is-pump-head-loss.html">pump head loss</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="step-3-choose-the-number-of-stages--2">Step 3: Choose the Number of Stages</h2><a class="header-anchor" href="#step-3-choose-the-number-of-stages--2" title="Step 3: Choose the Number of Stages" aria-label="Step 3: Choose the Number of Stages"></a></div>

<p>In a multistage pump, the impellers work in series. The same flow passes through every stage, and their heads add up. So the number of stages is roughly the required head divided by the head of one stage at the duty flow.</p>

<p>Shinjo&#39;s DF46-50 adds 57.5 m per stage at 28 m&sup3;/h. For the 270 m example: 270 &divide; 57.5 = 4.7, so five stages are needed. The published data for this model at 28 m&sup3;/h:</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Stages</th>
			<th>Head at 28 m&sup3;/h</th>
			<th>Shaft power</th>
			<th>Motor</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>3</td>
			<td>172.5 m</td>
			<td>24.8 kW</td>
			<td>37 kW</td>
		</tr>
		<tr>
			<td>4</td>
			<td>230 m</td>
			<td>33.1 kW</td>
			<td>55 kW</td>
		</tr>
		<tr>
			<td>5</td>
			<td>287.5 m</td>
			<td>41.4 kW</td>
			<td>55 kW</td>
		</tr>
		<tr>
			<td>6</td>
			<td>345 m</td>
			<td>49.6 kW</td>
			<td>75 kW</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Five stages give 287.5 m, which is 17.5 m more than needed. In practice, the pump will run slightly further out on its curve, where the system curve crosses it. Alternatively, the impellers can be trimmed, or a variable-frequency drive can reduce speed. Do not add a sixth stage &quot;for margin&quot;. It adds 57.5 m of head that would be burned off in a throttling valve, plus about 8 kW of shaft power.</p>

<p>You can check the shaft power from the head, flow and efficiency (53% for this model):</p>

<p class="sj-formula">P = &rho; &times; g &times; Q &times; H &divide; &eta; = 998 &times; 9.81 &times; (28 &divide; 3,600) &times; 287.5 &divide; 0.53 &asymp; 41.3 kW</p>

<p>Select the motor for the highest power anywhere on the allowable operating range, not just at the duty point. Read the <a href="https://www.shinjopump.com/news/what-is-a-pump-performance-curve.html">pump performance curve</a> out to maximum flow and, for liquids heavier than water, scale the power with density.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="step-4-check-npsh-at-the-first-stage--3">Step 4: Check NPSH at the First Stage</h2><a class="header-anchor" href="#step-4-check-npsh-at-the-first-stage--3" title="Step 4: Check NPSH at the First Stage" aria-label="Step 4: Check NPSH at the First Stage"></a></div>

<p>Only the first impeller sees the suction conditions, so the first stage decides whether the pump cavitates. Adding stages raises the discharge pressure but does nothing for the suction.</p>

<p>Manufacturers publish NPSH required as NPSH3: the suction head at which cavitation has already cut the first-stage head by 3%. The pump is cavitating at that point, so NPSH available must be higher, with a margin. Calculate NPSH available at the lowest liquid level, the highest temperature and the lowest suction vessel pressure together, using absolute pressures. Hot water is the usual problem. Its vapor pressure rises steeply, which is why feed pumps on deaerators sit far below the tank.</p>

<p>If NPSH is short, raise the tank, enlarge and shorten the suction pipe, cool the liquid, choose a lower-speed pump, or add a low-head booster pump in front.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="step-5-check-the-highest-pressure--4">Step 5: Check the Highest Pressure</h2><a class="header-anchor" href="#step-5-check-the-highest-pressure--4" title="Step 5: Check the Highest Pressure" aria-label="Step 5: Check the Highest Pressure"></a></div>

<p>The casing must hold the highest pressure it can ever see. That is the maximum suction pressure plus the pump&#39;s shut-off head, at maximum speed and maximum liquid density. It is not just the discharge pressure at the duty point. Compare it with the allowable working pressure of the casing, nozzles and seal at operating temperature. The hydrostatic test pressure, usually 1.5 times the allowable working pressure, is a factory test, not an operating limit.</p>

<p>Check the inlet pressure as well. The DF pump is rated for an inlet pressure below 0.6 MPa. That matters when it takes suction from a pressurized vessel or runs in series behind another pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="step-6-plan-for-thrust-seals-and-minimum-flow--5">Step 6: Plan for Thrust, Seals and Minimum Flow</h2><a class="header-anchor" href="#step-6-plan-for-thrust-seals-and-minimum-flow--5" title="Step 6: Plan for Thrust, Seals and Minimum Flow" aria-label="Step 6: Plan for Thrust, Seals and Minimum Flow"></a></div>

<p>Every impeller pushes the rotor toward the suction end, and in a multistage pump these forces add up. Ring-section multistage pumps usually balance them with a balance disc or drum and a thrust bearing. Balance devices rely on close clearances, so abrasive particles wear them and let the rotor shift. Keep the liquid clean, and fit a suction strainer where needed.</p>

<p>Ask the supplier what pressure the shaft seal sees. It depends on the design and is not always full discharge pressure.</p>

<p>At low flow, most of the motor&#39;s power turns into heat in a small amount of liquid, and the liquid recirculates inside the impellers. Ask for the minimum continuous flow. If the process can demand less, fit a minimum-flow bypass that returns liquid to the suction tank, not directly to the pump inlet.</p>

<div class="sj-warn">
<div class="sj-warn-title">Red lines for multistage pumps</div>

<ul>
	<li><b>Never run dry.</b> The balance device and wear rings have close clearances and seize without liquid.</li>
	<li><b>Never run below minimum flow</b> or against a closed discharge valve for long.</li>
	<li><b>Do not exceed the inlet pressure rating</b>, 0.6 MPa on the DF pump.</li>
	<li><b>Fill and vent the pump before starting.</b> Trapped air in the upper stages causes dry running.</li>
	<li><b>Keep abrasive solids out.</b> They wear the clearances that hold the rotor in place.</li>
</ul>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="shinjo-multistage-pumps-and-alternatives--6">Shinjo Multistage Pumps and Alternatives</h2><a class="header-anchor" href="#shinjo-multistage-pumps-and-alternatives--6" title="Shinjo Multistage Pumps and Alternatives" aria-label="Shinjo Multistage Pumps and Alternatives"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Pump</th>
			<th>Flow</th>
			<th>Head</th>
			<th>Construction and limits</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td><a href="https://www.shinjopump.com/cast-steel-multistage-pump-single-suction-15-336-m3-h.html">DF single-suction multistage</a></td>
			<td>15&ndash;336 m&sup3;/h</td>
			<td>144&ndash;690 m</td>
			<td>Cast iron, cast steel or stainless steel; &minus;20 to 105 &deg;C; inlet pressure below 0.6 MPa; 2,950 or 1,480 rpm</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/stainless-steel-multistage-centrifugal-pump-14-6-198-m.html">Stainless steel multistage</a></td>
			<td>0.3&ndash;10 m&sup3;/h</td>
			<td>14.6&ndash;198 m</td>
			<td>Stainless steel casing, impeller and shaft; tungsten carbide bearings and seal</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/partial-emission-pump-0-1-15-m3-h-16-120-m-0-75-37-kw.html">Partial emission pump</a></td>
			<td>0.1&ndash;15 m&sup3;/h</td>
			<td>16&ndash;120 m</td>
			<td>Single stage, 0.75&ndash;37 kW</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>For small clean-water duties of 2&ndash;32 m&sup3;/h, the compact <a href="https://www.shinjopump.com/cast-iron-multistage-centrifugal-pump-astm-25b-2-32-m3-h.html">cast iron multistage pump</a> has stainless steel impellers and inner parts in a cast iron frame, with motors of 0.37&ndash;3 kW. It handles water from &minus;15 to 70 &deg;C, or up to 120 &deg;C in its hot-water version.</p>

<div class="sj-gallery">
<figure><a href="https://www.shinjopump.com/cast-steel-multistage-pump-single-suction-15-336-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage%20Pumps/cast-steel-multistage-pump-single-suction.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage Pumps/resize/454bc12eca51e3b53480200e933d4445/cast-steel-multistage-pump-single-suction-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage Pumps/resize/454bc12eca51e3b53480200e933d4445/cast-steel-multistage-pump-single-suction-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo DF cast steel single-suction multistage pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo DF cast steel single-suction multistage pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>DF multistage</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/cast-iron-multistage-centrifugal-pump-astm-25b-2-32-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage%20Pumps/stainless-steel-multistage-centrifugal-pump%281%29.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage Pumps/resize/7b9c252785941e6f95f42d123ae802e4/stainless-steel-multistage-centrifugal-pump(1)-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage Pumps/resize/7b9c252785941e6f95f42d123ae802e4/stainless-steel-multistage-centrifugal-pump(1)-550x550.webp 550w" width="550" height="550"  
      alt="Shinjo cast iron multistage centrifugal pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo cast iron multistage centrifugal pump' loading='lazy'  sizes="(max-width: 550px) 96vw, 550px"  /></a>

<figcaption>Cast iron multistage</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/stainless-steel-multistage-centrifugal-pump-14-6-198-m.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage%20Pumps/stainless-steel-multistage-centrifugal-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage Pumps/resize/aa7f431f951afb2e32690ef549e8c525/stainless-steel-multistage-centrifugal-pump-320x321.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Multistage Pumps/resize/aa7f431f951afb2e32690ef549e8c525/stainless-steel-multistage-centrifugal-pump-400x401.webp 400w" width="400" height="401"  
      alt="Shinjo stainless steel multistage centrifugal pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo stainless steel multistage centrifugal pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>Stainless multistage</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/high-head-partial-emission-pump-16-120-m-0-1-15-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Chemical%20Process%20Pumps/high-head-partial-emission-pump-16-120-m-0-1-15-m3-h.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Chemical Process Pumps/resize/e77bd509fcbb1cecdc7394a77a00978d/high-head-partial-emission-pump-16-120-m-0-1-15-m3-h-235x158.webp 235w" width="235" height="158"  
      alt="Shinjo high head partial emission pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo high head partial emission pump' loading='lazy'  sizes="(max-width: 235px) 96vw, 235px"  /></a>

<figcaption>Partial emission pump</figcaption>
</figure>
</div>

<p>Choose the material from the liquid. Cast iron suits clean, cold water at moderate pressure. Cast steel suits higher pressures and hot water up to the DF&#39;s 105 &deg;C limit. Stainless steel suits corrosive liquids, demineralized water, which attacks cast iron, and hygienic duties.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="very-low-flow-at-high-head-consider-a-partial-emission-pump--7">Very Low Flow at High Head: Consider a Partial Emission Pump</h2><a class="header-anchor" href="#very-low-flow-at-high-head-consider-a-partial-emission-pump--7" title="Very Low Flow at High Head: Consider a Partial Emission Pump" aria-label="Very Low Flow at High Head: Consider a Partial Emission Pump"></a></div>

<p>A multistage pump sized for a very small flow ends up with small, inefficient stages, or with a larger pump running far below its best efficiency point and relying on a bypass. For flows up to 15 m&sup3;/h and heads up to 120 m, Shinjo&#39;s <a href="https://www.shinjopump.com/high-head-partial-emission-pump-16-120-m-0-1-15-m3-h.html">high head partial emission pump</a> reaches the head in a single stage. Its data table lists motor sizes for liquid densities of 1.0, 1.4 and 1.86, which shows how strongly power depends on density. Compare both options on curves, power and NPSH before deciding. For more on general selection, see <a href="https://www.shinjopump.com/news/how-to-select-a-centrifugal-pump.html">how to select a centrifugal pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-to-send-with-your-enquiry--8">What to Send with Your Enquiry</h2><a class="header-anchor" href="#what-to-send-with-your-enquiry--8" title="What to Send with Your Enquiry" aria-label="What to Send with Your Enquiry"></a></div>

<ul>
	<li>Minimum, normal and maximum flow, and the running time at each.</li>
	<li>Total head, or the system details to calculate it: elevations, vessel pressures and pipe layout.</li>
	<li>Liquid, temperature, density, viscosity and vapor pressure.</li>
	<li>Suction conditions: tank level, suction pressure and NPSH available.</li>
	<li>Maximum suction pressure, for the casing pressure check.</li>
	<li>Material requirements, power supply and any required standard, such as API 610 or ISO 9906 test grades.</li>
</ul>

<p class="sj-cta">Need a pump for a high-head duty? Send your duty data to SHINJO and we will <a href="https://www.shinjopump.com/contact.html">select the stages, material and motor</a> for you. See our full range of <a href="https://www.shinjopump.com/multistage-pumps.html">multistage pumps</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="faq--9">FAQ</h2><a class="header-anchor" href="#faq--9" title="FAQ" aria-label="FAQ"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="does-adding-stages-increase-the-flow-of-a-multistage-pump--10">Does adding stages increase the flow of a multistage pump?</h3><a class="header-anchor" href="#does-adding-stages-increase-the-flow-of-a-multistage-pump--10" title="Does adding stages increase the flow of a multistage pump?" aria-label="Does adding stages increase the flow of a multistage pump?"></a></div>

<p>No. Stages in series add head while carrying the same flow. The operating flow is where the pump curve crosses the system curve, so more stages shift that point only because the head rises.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="how-do-i-calculate-the-number-of-stages--11">How do I calculate the number of stages?</h3><a class="header-anchor" href="#how-do-i-calculate-the-number-of-stages--11" title="How do I calculate the number of stages?" aria-label="How do I calculate the number of stages?"></a></div>

<p>Divide the required total head by the head of one stage at the duty flow, then round up. For example, 270 m at 28 m&sup3;/h with a DF46-50, which adds 57.5 m per stage, needs five stages. Then check efficiency, power and NPSH for that selection.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="why-does-a-multistage-pump-cavitate-when-it-has-so-much-head--12">Why does a multistage pump cavitate when it has so much head?</h3><a class="header-anchor" href="#why-does-a-multistage-pump-cavitate-when-it-has-so-much-head--12" title="Why does a multistage pump cavitate when it has so much head?" aria-label="Why does a multistage pump cavitate when it has so much head?"></a></div>

<p>Because cavitation happens at the first impeller, which sees only the suction conditions. Extra stages raise the discharge pressure, not the suction pressure. Improve NPSH available, or choose a pump with a lower NPSH requirement.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="what-is-the-maximum-inlet-pressure-of-the-df-multistage-pump--13">What is the maximum inlet pressure of the DF multistage pump?</h3><a class="header-anchor" href="#what-is-the-maximum-inlet-pressure-of-the-df-multistage-pump--13" title="What is the maximum inlet pressure of the DF multistage pump?" aria-label="What is the maximum inlet pressure of the DF multistage pump?"></a></div>

<p>The DF pump is rated for an inlet pressure below 0.6 MPa. Check this when it takes suction from a pressurized vessel or runs in series behind a booster pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="when-is-a-partial-emission-pump-better-than-a-multistage-pump--14">When is a partial emission pump better than a multistage pump?</h3><a class="header-anchor" href="#when-is-a-partial-emission-pump-better-than-a-multistage-pump--14" title="When is a partial emission pump better than a multistage pump?" aria-label="When is a partial emission pump better than a multistage pump?"></a></div>

<p>When the flow is very small compared with the head: up to about 15 m&sup3;/h at heads up to 120 m. A single-stage partial emission pump then avoids a multistage pump running far below its best efficiency point.</p>
</div>
</div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>Non-Clogging Pump Selection for Solids, Fibers and Rags</title>
      <description><![CDATA[How to choose a non-clogging pump: match the impeller to the solids, read free passage and fiber ratings, and avoid the common causes of clogging.]]></description>
      <pubDate>Sun, 11 Oct 2026 11:56:32 +0000</pubDate>
      <link>https://www.shinjopump.com/news/non-clogging-pump.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/non-clogging-pump.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content">
<div class="sj-article">
<p class="sj-lead">Choose a non-clogging pump around whatever is most likely to block it, not just around flow and head. Hard lumps need a free passage larger than the biggest lump. Long fibers and rags need an impeller they cannot wrap around, or a cutter that shreds them. Grit and sand rarely block a pump, but they wear it, so they call for harder materials. Shinjo&#39;s <a href="https://www.shinjopump.com/iron-non-clogging-sludge-pump-8-300-m3-h-7-35-meters.html">non-clogging sludge pump</a> passes particles of 15&ndash;80 mm and fibers of 150&ndash;1,000 mm, depending on size. For rags, ropes and plastic sheet, the <a href="https://www.shinjopump.com/submersible-non-clogging-sludge-pump-15-145-m3-h-4-25-m.html">submersible non-clogging pump with a shredder</a> cuts them up before they reach the impeller.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="identify-what-will-block-the-pump--0">Identify What Will Block the Pump</h2><a class="header-anchor" href="#identify-what-will-block-the-pump--0" title="Identify What Will Block the Pump" aria-label="Identify What Will Block the Pump"></a></div>

<p>&quot;Dirty water&quot; is not a specification. Different solids block a pump in different ways, and each calls for a different design.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Solid</th>
			<th>How it causes trouble</th>
			<th>What to look for</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Hard lumps: stones, scale, metal</td>
			<td>Wedge in the narrowest passage</td>
			<td>Free passage larger than the largest lump, in the pump and in every valve and fitting</td>
		</tr>
		<tr>
			<td>Long fibers: textile waste, hair</td>
			<td>Wrap around the impeller hub and vane edges</td>
			<td>A high fiber rating and a channel or vortex impeller</td>
		</tr>
		<tr>
			<td>Rags, wet wipes, plastic film</td>
			<td>Twist into ropes and mats on the vanes and inlet</td>
			<td>A cutter (shredder) pump, or screening upstream</td>
		</tr>
		<tr>
			<td>Grease and sticky sludge</td>
			<td>Build up in layers and narrow the passages</td>
			<td>Smooth passages, regular flushing, mixing in the pit</td>
		</tr>
		<tr>
			<td>Sand and grit</td>
			<td>Rarely block, but wear the impeller and casing</td>
			<td>Hard, wear-resistant materials and moderate velocity</td>
		</tr>
		<tr>
			<td>Sludge settled on the pit floor</td>
			<td>Reaches the pump as a thick slug at start-up</td>
			<td>A mixing device that keeps the solids suspended</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Look at the worst case, not the average. A batch discharge at the end of a shift, or the first flush after a rainstorm, can block a pump that handled weeks of normal flow.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="impeller-types-and-their-trade-offs--1">Impeller Types and Their Trade-Offs</h2><a class="header-anchor" href="#impeller-types-and-their-trade-offs--1" title="Impeller Types and Their Trade-Offs" aria-label="Impeller Types and Their Trade-Offs"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Impeller</th>
			<th>Best for</th>
			<th>Trade-off</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Single-channel (single vane)</td>
			<td>Large solids and fibers; widest free passage for its size</td>
			<td>Unbalanced hydraulic forces, so more vibration away from the design point</td>
		</tr>
		<tr>
			<td>Double-channel (two vanes)</td>
			<td>General sewage and larger flows</td>
			<td>Smaller passage than a single-channel impeller of the same size, but smoother running</td>
		</tr>
		<tr>
			<td>Vortex (recessed)</td>
			<td>Stringy, sludgy or gassy liquids; most solids never touch the impeller</td>
			<td>Lowest efficiency of the group</td>
		</tr>
		<tr>
			<td>Cutter or shredder</td>
			<td>Rags, ropes, cloth strips and plastic sheet</td>
			<td>Lower flow and head; cutters wear and cannot cut hard objects such as metal</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Most sewage pumps use single- or double-vane impellers with large channels. The <a href="https://www.shinjopump.com/jywq-automated-homogenize-sewage-pump-flow-capacity-10-600-m3-h.html">JYWQ</a>, for example, uses a double-channel non-clogging impeller. For a deeper look at impeller construction, see <a href="https://www.shinjopump.com/news/what-is-the-differences-between-open-impeller-semi-open-impeller-and-closed-impeller.html">open, semi-open and closed impellers</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="read-the-solids-rating-correctly--2">Read the Solids Rating Correctly</h2><a class="header-anchor" href="#read-the-solids-rating-correctly--2" title="Read the Solids Rating Correctly" aria-label="Read the Solids Rating Correctly"></a></div>

<p><strong>Free passage</strong> is the diameter of the largest sphere that can pass through the pump. It tells you about hard lumps, and nothing about fibers. A strip of cloth far thinner than the free passage can still catch on a vane edge and wrap.</p>

<p><strong>Fiber rating</strong> is the longest fiber the pump can pass. Across Shinjo&#39;s non-clogging sludge pump range, particle tolerance runs from 15 to 80 mm and fiber tolerance from 150 to 1,000 mm. Both rise with pump size, so check the values for the model you select. The <a href="https://www.shinjopump.com/zw-self-priming-non-clogging-sewage-pump-8-800-m3-h.html">ZW self-priming non-clogging pump</a> passes suspended solids up to 60% of its bore and fibers up to five times its bore. A DN100 ZW therefore passes solids of about 60 mm and fibers of about 500 mm.</p>

<p><strong>The whole route counts.</strong> A large pump passage is wasted if a check valve, reducer or strainer downstream is smaller. Oregon&#39;s design rules for wastewater pump stations, for example, require raw sewage pumps to pass at least a 63 mm (2&frac12; in) sphere and preferably 76 mm (3 in), and require the piping and valves to pass 76 mm.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="shinjo-non-clogging-pumps-compared--3">Shinjo Non-Clogging Pumps Compared</h2><a class="header-anchor" href="#shinjo-non-clogging-pumps-compared--3" title="Shinjo Non-Clogging Pumps Compared" aria-label="Shinjo Non-Clogging Pumps Compared"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Pump</th>
			<th>Construction</th>
			<th>Flow</th>
			<th>Head</th>
			<th>Solids handling</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td><a href="https://www.shinjopump.com/iron-non-clogging-sludge-pump-8-300-m3-h-7-35-meters.html">Non-clogging sludge pump</a>, iron or stainless steel</td>
			<td>Iron or stainless steel</td>
			<td>8&ndash;300 m&sup3;/h</td>
			<td>7&ndash;35 m</td>
			<td>Particles 15&ndash;80 mm, fibers 150&ndash;1,000 mm</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/stainless-steel-non-clogging-sludge-pump-7-35m-10-950-m3-h.html">Stainless steel non-clogging sludge pump</a></td>
			<td>Stainless steel, oil-filled submersible motor</td>
			<td>10&ndash;950 m&sup3;/h</td>
			<td>7&ndash;35 m</td>
			<td>Large solids and fibers, motors up to 110 kW</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/submersible-non-clogging-sludge-pump-15-145-m3-h-4-25-m.html">Submersible pump with shredder</a></td>
			<td>Submersible, with cutter</td>
			<td>15&ndash;145 m&sup3;/h</td>
			<td>4&ndash;25 m</td>
			<td>Cuts long fibers, plastic sheet, cloth strips and ropes</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/zw-self-priming-non-clogging-sewage-pump-8-800-m3-h.html">ZW self-priming non-clogging</a></td>
			<td>Self-priming, installed above ground</td>
			<td>8&ndash;800 m&sup3;/h</td>
			<td>Up to 70 m</td>
			<td>Solids up to 60% of bore, fibers up to 5 times bore</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/jywq-automated-homogenize-sewage-pump-flow-capacity-10-600-m3-h.html">JYWQ with mixer</a></td>
			<td>Submersible, with mixing device</td>
			<td>10&ndash;600 m&sup3;/h</td>
			<td>7&ndash;40 m</td>
			<td>Double-channel impeller; mixer stirs settled sludge</td>
		</tr>
	</tbody>
</table></div>
</div>

<div class="sj-gallery">
<figure><a href="https://www.shinjopump.com/iron-non-clogging-sludge-pump-8-300-m3-h-7-35-meters.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage%20Pumps/iron-non-clogging-sludge-pump-8-300-m3-h-7-35-meters.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/bf1b60e36f752a35fe2da0645576b89f/iron-non-clogging-sludge-pump-8-300-m3-h-7-35-meters-252x164.webp 252w" width="252" height="164"  
      alt="Shinjo iron non-clogging sludge pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo iron non-clogging sludge pump' loading='lazy'  sizes="(max-width: 252px) 96vw, 252px"  /></a>

<figcaption>Non-clogging sludge pump</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/submersible-non-clogging-sludge-pump-15-145-m3-h-4-25-m.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage%20Pumps/submersible-non-clogging-sludge-pump-15-145-m3-h-4-25-m.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/f11a91bd9b10a1d1c5b138bcb55b7d7f/submersible-non-clogging-sludge-pump-15-145-m3-h-4-25-m-320x362.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/f11a91bd9b10a1d1c5b138bcb55b7d7f/submersible-non-clogging-sludge-pump-15-145-m3-h-4-25-m-430x486.webp 430w" width="430" height="486"  
      alt="Shinjo submersible non-clogging pump with shredder" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo submersible non-clogging pump with shredder' loading='lazy'  sizes="(max-width: 430px) 96vw, 430px"  /></a>

<figcaption>With shredder</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/zw-self-priming-non-clogging-sewage-pump-8-800-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Self%20Priming%20Pumps/zw-self-suction-non-clogging-sewage-pump_400x400.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Self Priming Pumps/resize/267585c503df4a9eb8f95e58a4fae3bd/zw-self-suction-non-clogging-sewage-pump_400x400-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Self Priming Pumps/resize/267585c503df4a9eb8f95e58a4fae3bd/zw-self-suction-non-clogging-sewage-pump_400x400-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo ZW self-priming non-clogging sewage pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo ZW self-priming non-clogging sewage pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>ZW, self-priming</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/jywq-automated-homogenize-sewage-pump-flow-capacity-10-600-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage%20Pumps/jywq-automated-homogenize-sewage-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/cea4663693478275ddc8f99740981570/jywq-automated-homogenize-sewage-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/cea4663693478275ddc8f99740981570/jywq-automated-homogenize-sewage-pump-640x640.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/cea4663693478275ddc8f99740981570/jywq-automated-homogenize-sewage-pump-731x731.webp 731w" width="731" height="731"  
      alt="Shinjo JYWQ sewage pump with automatic mixing device" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo JYWQ sewage pump with automatic mixing device' loading='lazy'  sizes="(max-width: 731px) 96vw, 731px"  /></a>

<figcaption>JYWQ, with mixer</figcaption>
</figure>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="run-the-pump-at-the-right-operating-point--4">Run the Pump at the Right Operating Point</h2><a class="header-anchor" href="#run-the-pump-at-the-right-operating-point--4" title="Run the Pump at the Right Operating Point" aria-label="Run the Pump at the Right Operating Point"></a></div>

<p>Many blockages blamed on the pump are caused by how it runs.</p>

<ul>
	<li><strong>Stay near the best efficiency point.</strong> At low flow, liquid recirculates inside the pump, solids settle in the casing, and single-vane impellers vibrate. Calculate the <a href="https://www.shinjopump.com/news/what-is-pump-head-and-total-head-total-dynamic-head.html">total dynamic head</a> at both high and low pit levels, and check both points on the <a href="https://www.shinjopump.com/news/what-is-a-pump-performance-curve.html">pump performance curve</a>.</li>
	<li><strong>Keep the velocity up in the discharge line.</strong> Slow flow lets solids settle in the pipe. Oregon&#39;s rules call for 3.5&ndash;8 ft/s (about 1.1&ndash;2.4 m/s) in force mains. With a variable-frequency drive, they require at least 3.5 ft/s once in each pumping cycle and never less than 2 ft/s (0.6 m/s).</li>
	<li><strong>Do not slow a variable-speed pump too far.</strong> Below a certain speed, solids stop moving and the impeller loses its ability to shed fibers.</li>
	<li><strong>Do not oversize the motor to fight clogging.</strong> A bigger motor does not change the passage geometry. Size it for the full operating range of the curve.</li>
</ul>

<div class="sj-warn">
<div class="sj-warn-title">Common causes of clogging that are not the pump</div>

<ul>
	<li><b>A check valve or reducer smaller than the pump outlet.</b> Solids pass the pump and jam downstream.</li>
	<li><b>Long running at low flow</b>, which lets solids settle and fibers collect.</li>
	<li><b>A variable-speed drive set too slow</b> to carry solids through the pipe.</li>
	<li><b>A standby pump left standing in settled sludge.</b> Alternate the duty and standby pumps.</li>
	<li><b>Incoming flow dropping straight onto the pump inlet</b>, which drives air and debris into it.</li>
</ul>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="design-the-pit-to-prevent-blockages--5">Design the Pit to Prevent Blockages</h2><a class="header-anchor" href="#design-the-pit-to-prevent-blockages--5" title="Design the Pit to Prevent Blockages" aria-label="Design the Pit to Prevent Blockages"></a></div>

<p>The wet well decides much of what the pump sees. Bring the incoming flow in away from the pump inlet, and avoid dead corners where solids collect. Slope the floor toward the pump. Where sludge settles, a mixer keeps it in suspension. The JYWQ has a built-in mixing device, with a stirring diameter of 1,200&ndash;3,000 mm, that turns settled sediment back into a slurry the pump can carry away.</p>

<p>If rags are a constant problem and a cutter pump does not suit the duty, a screen upstream of the pit removes them. The screen then needs regular cleaning, or the blockage just moves upstream.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="materials-and-seals--6">Materials and Seals</h2><a class="header-anchor" href="#materials-and-seals--6" title="Materials and Seals" aria-label="Materials and Seals"></a></div>

<p>Choose materials for both corrosion and wear. On the ZW, cast iron suits liquids from pH 6 to 9 and stainless steel from pH 2 to 13. Abrasive grit needs hard wear surfaces and moderate speed. Where corrosion and abrasion occur together, as in many industrial effluents, the combined effect is worse than either alone.</p>

<p>Shinjo&#39;s non-clogging sludge pumps use two sets of hard-alloy mechanical seals. Hard faces matter in wastewater, because grit grinds away softer seal faces. Submersible versions run the seals in an oil chamber that protects the motor.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-to-send-with-your-enquiry--7">What to Send with Your Enquiry</h2><a class="header-anchor" href="#what-to-send-with-your-enquiry--7" title="What to Send with Your Enquiry" aria-label="What to Send with Your Enquiry"></a></div>

<ul>
	<li>Flow, and the head at high and low pit levels.</li>
	<li>Solids: largest lump, fiber length, rags or wipes, grit, and solids concentration.</li>
	<li>A photo or sample of the worst material, if available.</li>
	<li>Liquid temperature, pH and chemical content.</li>
	<li>Pit dimensions and how the pump will be installed.</li>
	<li>Discharge pipe size and length, including valves and reducers.</li>
</ul>

<p class="sj-cta">Need a pump that will not block on your wastewater? Send a description of the solids to SHINJO and we will <a href="https://www.shinjopump.com/contact.html">recommend a non-clogging pump</a> and impeller. See our full range of <a href="https://www.shinjopump.com/sewage-pumps.html">sewage pumps</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="faq--8">FAQ</h2><a class="header-anchor" href="#faq--8" title="FAQ" aria-label="FAQ"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-non-clogging-pump-still-clog--9">Can a non-clogging pump still clog?</h3><a class="header-anchor" href="#can-a-non-clogging-pump-still-clog--9" title="Can a non-clogging pump still clog?" aria-label="Can a non-clogging pump still clog?"></a></div>

<p>Yes. &quot;Non-clogging&quot; describes a design aim, not a guarantee. Oversized lumps, long rags, grease build-up, low-flow operation and undersized valves downstream can all stop a non-clogging pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="what-size-of-solids-can-a-non-clogging-pump-pass--10">What size of solids can a non-clogging pump pass?</h3><a class="header-anchor" href="#what-size-of-solids-can-a-non-clogging-pump-pass--10" title="What size of solids can a non-clogging pump pass?" aria-label="What size of solids can a non-clogging pump pass?"></a></div>

<p>It depends on the pump size and impeller. Shinjo&#39;s non-clogging sludge pumps pass particles of 15&ndash;80 mm and fibers of 150&ndash;1,000 mm across the range. The ZW self-priming pump passes solids up to 60% of its bore.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="is-a-vortex-or-a-channel-impeller-better-for-fibrous-wastewater--11">Is a vortex or a channel impeller better for fibrous wastewater?</h3><a class="header-anchor" href="#is-a-vortex-or-a-channel-impeller-better-for-fibrous-wastewater--11" title="Is a vortex or a channel impeller better for fibrous wastewater?" aria-label="Is a vortex or a channel impeller better for fibrous wastewater?"></a></div>

<p>A vortex impeller keeps most solids away from the impeller and copes well with stringy material, but it is less efficient. A channel impeller is more efficient and passes large solids. For rags and plastic film, a cutter pump is often the most reliable answer.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="when-should-i-choose-a-pump-with-a-cutter--12">When should I choose a pump with a cutter?</h3><a class="header-anchor" href="#when-should-i-choose-a-pump-with-a-cutter--12" title="When should I choose a pump with a cutter?" aria-label="When should I choose a pump with a cutter?"></a></div>

<p>When the wastewater carries rags, wipes, ropes or plastic sheet, and the flow and head are within the cutter pump&#39;s range: 15&ndash;145 m&sup3;/h and 4&ndash;25 m for Shinjo&#39;s shredder model. Cutter pumps are not suited to hard objects such as metal or stones.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="does-a-bigger-motor-prevent-clogging--13">Does a bigger motor prevent clogging?</h3><a class="header-anchor" href="#does-a-bigger-motor-prevent-clogging--13" title="Does a bigger motor prevent clogging?" aria-label="Does a bigger motor prevent clogging?"></a></div>

<p>No. Extra power does not change the passage size or stop fibers from wrapping. Prevent clogging with the right impeller, free passage, operating point and pit design, and size the motor for the full operating range.</p>
</div>
</div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>Self-Priming vs Submersible Sewage Pump: Which to Choose</title>
      <description><![CDATA[Self-priming or submersible sewage pump? Compare suction lift, temperature, solids and maintenance, with a worked NPSH example and Shinjo models.]]></description>
      <pubDate>Sun, 11 Oct 2026 11:53:06 +0000</pubDate>
      <link>https://www.shinjopump.com/news/self-priming-vs-submersible-sewage-pump.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/self-priming-vs-submersible-sewage-pump.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content">
<div class="sj-article">
<p class="sj-lead">Choose a self-priming sewage pump when the lowest liquid level is within about 4.5 m of the pump and you want the pump and motor above ground, where they are easy to reach. Choose a submersible sewage pump when the pit is deeper, space is tight or the suction line would be long. There is also a middle option: a vertical submerged pump, with the pump in the liquid and the motor above the pit. In Shinjo&#39;s range these are the <a href="https://www.shinjopump.com/zw-self-priming-non-clogging-sewage-pump-8-800-m3-h.html">ZW self-priming non-clogging sewage pump</a> (8&ndash;800 m&sup3;/h), the <a href="https://www.shinjopump.com/wq-submersible-sewage-pump-capacity-10-6000-m3-h.html">WQ submersible sewage pump</a> (10&ndash;6,000 m&sup3;/h) and the <a href="https://www.shinjopump.com/yw-vertical-submersible-sewage-pump-flow-rate-q-8-1000-m3-h.html">YW vertical submerged sewage pump</a> (8&ndash;1,000 m&sup3;/h).</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="three-ways-to-pump-a-sewage-pit--0">Three Ways to Pump a Sewage Pit</h2><a class="header-anchor" href="#three-ways-to-pump-a-sewage-pit--0" title="Three Ways to Pump a Sewage Pit" aria-label="Three Ways to Pump a Sewage Pit"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>&nbsp;</th>
			<th>ZW self-priming</th>
			<th>WQ submersible</th>
			<th>YW vertical submerged</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Where it sits</td>
			<td>Beside the pit, above the liquid</td>
			<td>At the bottom of the pit, in the liquid</td>
			<td>Pump in the liquid, motor on a plate above the pit</td>
		</tr>
		<tr>
			<td>Suction lift</td>
			<td>Up to 4.5&ndash;5.5 m, with a suction pipe up to 10 m</td>
			<td>None</td>
			<td>None</td>
		</tr>
		<tr>
			<td>Flow</td>
			<td>8&ndash;800 m&sup3;/h</td>
			<td>10&ndash;6,000 m&sup3;/h</td>
			<td>8&ndash;1,000 m&sup3;/h</td>
		</tr>
		<tr>
			<td>Head</td>
			<td>Up to 70 m</td>
			<td>5&ndash;65 m</td>
			<td>6&ndash;65 m</td>
		</tr>
		<tr>
			<td>Liquid temperature</td>
			<td>Up to 80 &deg;C (200 &deg;C on request)</td>
			<td>0&ndash;55 &deg;C</td>
			<td>0&ndash;80 &deg;C</td>
		</tr>
		<tr>
			<td>Maintenance access</td>
			<td>Pump and motor fully above ground</td>
			<td>Lifted out on guide rails</td>
			<td>Motor above ground; the pump is lifted out with its column</td>
		</tr>
		<tr>
			<td>Main risks</td>
			<td>Air leaks in the suction, loss of prime, too much lift</td>
			<td>Seal leakage into the motor, cable damage, low-level cooling</td>
			<td>Pit depth limited by the column length</td>
		</tr>
	</tbody>
</table></div>
</div>

<div class="sj-gallery sj-g3">
<figure><a href="https://www.shinjopump.com/zw-self-priming-non-clogging-sewage-pump-8-800-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Self%20Priming%20Pumps/zw-self-suction-non-clogging-sewage-pump_400x400.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Self Priming Pumps/resize/267585c503df4a9eb8f95e58a4fae3bd/zw-self-suction-non-clogging-sewage-pump_400x400-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Self Priming Pumps/resize/267585c503df4a9eb8f95e58a4fae3bd/zw-self-suction-non-clogging-sewage-pump_400x400-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo ZW self-priming non-clogging sewage pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo ZW self-priming non-clogging sewage pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>ZW, self-priming</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/wq-submersible-sewage-pump-capacity-10-6000-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage%20Pumps/wq-submersible-sewage-pump-capacity-10-6000-m3-h.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/ce7608400c453c9669a0972db15d7b20/wq-submersible-sewage-pump-capacity-10-6000-m3-h-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/ce7608400c453c9669a0972db15d7b20/wq-submersible-sewage-pump-capacity-10-6000-m3-h-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo WQ submersible sewage pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo WQ submersible sewage pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>WQ, submersible</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/yw-vertical-submersible-sewage-pump-flow-rate-q-8-1000-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage%20Pumps/yw-semi-submersible-sewage-pump-flow-rate-q-9-460-m3-h.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/15fe9ae55bffa9c81efb6d1826f4c032/yw-semi-submersible-sewage-pump-flow-rate-q-9-460-m3-h-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/15fe9ae55bffa9c81efb6d1826f4c032/yw-semi-submersible-sewage-pump-flow-rate-q-9-460-m3-h-640x640.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Sewage Pumps/resize/15fe9ae55bffa9c81efb6d1826f4c032/yw-semi-submersible-sewage-pump-flow-rate-q-9-460-m3-h-679x679.webp 679w" width="679" height="679"  
      alt="Shinjo YW vertical submerged sewage pump with motor above the pit" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo YW vertical submerged sewage pump with motor above the pit' loading='lazy'  sizes="(max-width: 679px) 96vw, 679px"  /></a>

<figcaption>YW, vertical submerged</figcaption>
</figure>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="start-with-the-suction-lift--1">Start with the Suction Lift</h2><a class="header-anchor" href="#start-with-the-suction-lift--1" title="Start with the Suction Lift" aria-label="Start with the Suction Lift"></a></div>

<p>A self-priming pump does not pull liquid up. It lowers the pressure at its inlet, and atmospheric pressure pushes the liquid up the suction pipe. At sea level, atmospheric pressure equals about 10.3 m of water, and that is the theoretical limit. In practice, vapor pressure, friction in the suction pipe and the pump&#39;s own NPSH requirement use up much of it. The ZW is rated for a self-priming height of 4.5&ndash;5.5 m with a suction pipe up to 10 m long.</p>

<p>Two site conditions reduce the usable lift:</p>

<ul>
	<li><strong>Altitude.</strong> At 1,000 m above sea level, atmospheric pressure is about 9.2 m of water, so you lose more than a meter compared with sea level.</li>
	<li><strong>Temperature.</strong> Warm wastewater has a higher vapor pressure and boils more easily at the low pressure inside the pump inlet.</li>
</ul>

<p>Check the lift with an NPSH calculation at the lowest liquid level and the highest liquid temperature. Example: a pump station at 500 m altitude, wastewater at 30 &deg;C, the lowest level 4.0 m below the pump inlet, and 0.8 m of friction loss in the suction pipe:</p>

<p class="sj-formula">NPSHa = atmospheric head &minus; vapor pressure head &minus; static lift &minus; suction losses<br />
NPSHa = 9.77 &minus; 0.43 &minus; 4.0 &minus; 0.8 &asymp; 4.5 m</p>

<p>Oregon&#39;s design rules for wastewater pump stations require a safety margin of at least 6 ft (1.8 m) above the pump&#39;s NPSH required at suction-lift stations. In this example, the pump&#39;s NPSH required at the duty point must therefore be no more than about 2.7 m. If it is higher, lower the pump, shorten the suction line or choose a submersible pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="how-a-self-priming-sewage-pump-works--2">How a Self-Priming Sewage Pump Works</h2><a class="header-anchor" href="#how-a-self-priming-sewage-pump-works--2" title="How a Self-Priming Sewage Pump Works" aria-label="How a Self-Priming Sewage Pump Works"></a></div>

<p>The ZW uses an external-mixing, axial back-flow design. Its casing holds a reserve of liquid. When the pump starts, the impeller mixes this liquid with the air in the suction pipe, separates the air in the casing, discharges it and returns the liquid to the impeller. After a few cycles, the suction pipe is full and the pump delivers normally. It needs no foot valve.</p>

<p>The casing must be filled with liquid before the first start. After that it keeps its reserve between starts. Reliable priming depends on the installation:</p>

<ul>
	<li>Keep the suction pipe short, no longer than 10 m, and completely airtight. A small leak lets in air without dripping, so it is easy to miss.</li>
	<li>Run the suction pipe so that it rises steadily to the pump, with no high points where air collects.</li>
	<li>Fit a check valve in the discharge, and give the air a way out during priming.</li>
</ul>

<div class="sj-warn">
<div class="sj-warn-title">Red lines for self-priming sewage pumps</div>

<ul>
	<li><b>Never start the first time without filling the casing.</b> Self-priming does not mean the pump can start dry.</li>
	<li><b>No air leaks in the suction pipe.</b> They are the most common cause of failed priming.</li>
	<li><b>Do not exceed the rated lift</b> after allowing for altitude and liquid temperature.</li>
	<li><b>No suction pipe longer than 10 m.</b> Longer pipes take too long to prime.</li>
</ul>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-a-submersible-sewage-pump-needs--3">What a Submersible Sewage Pump Needs</h2><a class="header-anchor" href="#what-a-submersible-sewage-pump-needs--3" title="What a Submersible Sewage Pump Needs" aria-label="What a Submersible Sewage Pump Needs"></a></div>

<p>A submersible pump avoids suction lift entirely, but it brings its own conditions.</p>

<ul>
	<li><strong>Liquid temperature.</strong> The WQ is rated for liquids from 0 to 55 &deg;C. For hotter industrial effluent, use the ZW or YW, which are rated to 80 &deg;C.</li>
	<li><strong>Motor cooling.</strong> Most submersible motors are cooled by the surrounding liquid, so the stop level must keep the motor covered. Some designs, such as the <a href="https://www.shinjopump.com/jywq-automated-homogenize-sewage-pump-flow-capacity-10-600-m3-h.html">JYWQ</a>, have an internal cooling circuit and can run down to the lowest pit level.</li>
	<li><strong>Seals.</strong> A double mechanical seal in an oil chamber protects the motor. Where a moisture sensor is fitted in the oil chamber, it warns of seal wear before water reaches the windings.</li>
	<li><strong>Retrieval.</strong> Guide rails and an automatic discharge coupling let you lift the pump out without entering the pit. Plan the lifting gear and overhead clearance before ordering. Never lift the pump by its cable.</li>
	<li><strong>Hazardous gas.</strong> Sewage pits can contain flammable gas. A pump in the pit needs explosion-proof certification. A motor above the pit, as on the ZW and YW, avoids the problem.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="which-pump-for-which-site--4">Which Pump for Which Site?</h2><a class="header-anchor" href="#which-pump-for-which-site--4" title="Which Pump for Which Site?" aria-label="Which Pump for Which Site?"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Site condition</th>
			<th>Best choice</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Lowest level within about 4.5 m of the pump; frequent maintenance</td>
			<td>ZW self-priming</td>
		</tr>
		<tr>
			<td>Pit deeper than the self-priming lift, or a long suction line</td>
			<td>WQ submersible, or YW if the motor must stay dry</td>
		</tr>
		<tr>
			<td>Liquid above 55 &deg;C</td>
			<td>ZW or YW, both rated to 80 &deg;C</td>
		</tr>
		<tr>
			<td>Flow above 1,000 m&sup3;/h</td>
			<td>WQ, up to 6,000 m&sup3;/h</td>
		</tr>
		<tr>
			<td>Head above 65 m</td>
			<td>ZW, up to 70 m</td>
		</tr>
		<tr>
			<td>Sludge settles on the pit floor</td>
			<td>JYWQ, which has a mixing device that stirs sediment back into suspension</td>
		</tr>
		<tr>
			<td>Long fibers, rags and plastic strips</td>
			<td>A submersible pump with a cutter, such as the <a href="https://www.shinjopump.com/submersible-non-clogging-sludge-pump-15-145-m3-h-4-25-m.html">submersible non-clogging sludge pump</a></td>
		</tr>
	</tbody>
</table></div>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="solids-chemistry-and-materials--5">Solids, Chemistry and Materials</h2><a class="header-anchor" href="#solids-chemistry-and-materials--5" title="Solids, Chemistry and Materials" aria-label="Solids, Chemistry and Materials"></a></div>

<p>Whichever layout you choose, the impeller and passages must pass the solids in the wastewater. Oregon&#39;s wastewater design rules, for example, require raw sewage pumps to pass at least a 63 mm (2&frac12; in) sphere and preferably 76 mm (3 in), with piping and valves passing 76 mm. The ZW passes suspended solids up to 60% of the pump bore and fibers up to five times the bore. In a self-priming installation, also check the suction pipe, elbows and any strainer, because a blockage there stops the pump just as surely.</p>

<p>Match the material to the chemistry. On the ZW, cast iron suits liquids from pH 6 to 9 and stainless steel from pH 2 to 13. The liquid density must not exceed 1,240 kg/m&sup3;. For more on the basics, see <a href="https://www.shinjopump.com/news/what-is-a-sewage-pump-and-how-does-it-applys-for-work.html">what a sewage pump is and how it works</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="compare-running-cost-at-real-operating-points--6">Compare Running Cost at Real Operating Points</h2><a class="header-anchor" href="#compare-running-cost-at-real-operating-points--6" title="Compare Running Cost at Real Operating Points" aria-label="Compare Running Cost at Real Operating Points"></a></div>

<p>The liquid level changes as the pit fills and empties, so the static head and the operating point change too. Calculate the <a href="https://www.shinjopump.com/news/what-is-pump-head-and-total-head-total-dynamic-head.html">total dynamic head</a> at both high and low levels and compare pump curves across that range, not at one rated point. A submersible pump avoids suction losses. A self-priming pump costs less to maintain because nothing has to be lifted out of the pit. Include lifting equipment, civil works and the cost of an overflow when a pump is out of service, not just the purchase price.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-to-send-with-your-enquiry--7">What to Send with Your Enquiry</h2><a class="header-anchor" href="#what-to-send-with-your-enquiry--7" title="What to Send with Your Enquiry" aria-label="What to Send with Your Enquiry"></a></div>

<ul>
	<li>Flow, and the head at high and low pit levels.</li>
	<li>Pit depth, the lowest liquid level and the site altitude.</li>
	<li>Liquid temperature, pH and chemical content.</li>
	<li>Solids: maximum particle size, fibers, rags and grit.</li>
	<li>Whether flammable gas may be present in the pit.</li>
	<li>Power supply and control requirements.</li>
</ul>

<p class="sj-cta">Deciding between a self-priming and a submersible pump? Send your pit layout to SHINJO and we will <a href="https://www.shinjopump.com/contact.html">recommend the right sewage pump</a>. See our full ranges of <a href="https://www.shinjopump.com/sewage-pumps.html">sewage pumps</a> and <a href="https://www.shinjopump.com/self-priming-pumps.html">self-priming pumps</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="faq--8">FAQ</h2><a class="header-anchor" href="#faq--8" title="FAQ" aria-label="FAQ"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="how-high-can-a-self-priming-sewage-pump-lift--9">How high can a self-priming sewage pump lift?</h3><a class="header-anchor" href="#how-high-can-a-self-priming-sewage-pump-lift--9" title="How high can a self-priming sewage pump lift?" aria-label="How high can a self-priming sewage pump lift?"></a></div>

<p>The ZW is rated for a self-priming height of 4.5&ndash;5.5 m with a suction pipe up to 10 m long. The usable lift is lower at high altitude and with warm liquid, so confirm it with an NPSH calculation at the lowest pit level.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="does-a-self-priming-sewage-pump-need-water-before-the-first-start--10">Does a self-priming sewage pump need water before the first start?</h3><a class="header-anchor" href="#does-a-self-priming-sewage-pump-need-water-before-the-first-start--10" title="Does a self-priming sewage pump need water before the first start?" aria-label="Does a self-priming sewage pump need water before the first start?"></a></div>

<p>Yes. Fill the casing with liquid before the first start. The pump then keeps a reserve of liquid in the casing for later starts. Self-priming does not mean it can start or run dry.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-submersible-sewage-pump-handle-hot-wastewater--11">Can a submersible sewage pump handle hot wastewater?</h3><a class="header-anchor" href="#can-a-submersible-sewage-pump-handle-hot-wastewater--11" title="Can a submersible sewage pump handle hot wastewater?" aria-label="Can a submersible sewage pump handle hot wastewater?"></a></div>

<p>Only within its rating. The WQ is rated for liquids up to 55 &deg;C. For hotter industrial effluent, use a pump with the motor out of the liquid, such as the ZW or YW, which are rated to 80 &deg;C.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="which-is-easier-to-maintain-a-self-priming-or-a-submersible-pump--12">Which is easier to maintain, a self-priming or a submersible pump?</h3><a class="header-anchor" href="#which-is-easier-to-maintain-a-self-priming-or-a-submersible-pump--12" title="Which is easier to maintain, a self-priming or a submersible pump?" aria-label="Which is easier to maintain, a self-priming or a submersible pump?"></a></div>

<p>A self-priming pump, because the pump, seal and motor are above ground. A submersible pump has to be lifted out on its guide rails, which needs lifting equipment and clear access above the pit.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="which-pump-is-better-for-a-deep-pit--13">Which pump is better for a deep pit?</h3><a class="header-anchor" href="#which-pump-is-better-for-a-deep-pit--13" title="Which pump is better for a deep pit?" aria-label="Which pump is better for a deep pit?"></a></div>

<p>A submersible or vertical submerged pump. A self-priming pump cannot lift more than about 4.5&ndash;5.5 m, so a deeper pit would need the pump to be installed below ground, which loses its main advantage.</p>
</div>
</div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>High Temperature Magnetic Drive Pump for 300–350 °C</title>
      <description><![CDATA[How to select a high temperature magnetic drive pump for 300–350 °C: magnet limits, NPSH when hot, cold-start torque, cooling, and CQB-G vs MT-HTP.]]></description>
      <pubDate>Sun, 11 Oct 2026 11:56:51 +0000</pubDate>
      <link>https://www.shinjopump.com/news/high-temperature-magnetic-drive-pump.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/high-temperature-magnetic-drive-pump.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content">
<div class="sj-article">
<p class="sj-lead">A high temperature magnetic drive pump for 300&ndash;350 &deg;C liquids has to do three things the liquid makes difficult. It must keep its magnets cooler than the liquid, keep its internal bearings wet, and keep its pressure boundary within rating at temperature. Shinjo&#39;s <a href="https://www.shinjopump.com/cqb-g-high-temp-magnetic-drive-pump-temperature-up-to-300.html">CQB-G</a> is rated for liquids up to 300 &deg;C and the <a href="https://www.shinjopump.com/mt-htp-high-temp-magnetic-drive-pump-temperature-up-to-350.html">MT-HTP</a> for liquids up to 350 &deg;C. Both cover 3.2&ndash;100 m&sup3;/h in stainless steel. Choose the rating from the hottest temperature the pump can see, then check NPSH, cold-start torque, cooling and warm-up. If a small seal leak is acceptable on hot thermal oil, a sealed hot oil pump is the simpler alternative.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="cqb-g-or-mt-htp-which-rating-do-you-need--0">CQB-G or MT-HTP: Which Rating Do You Need?</h2><a class="header-anchor" href="#cqb-g-or-mt-htp-which-rating-do-you-need--0" title="CQB-G or MT-HTP: Which Rating Do You Need?" aria-label="CQB-G or MT-HTP: Which Rating Do You Need?"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>&nbsp;</th>
			<th>CQB-G</th>
			<th>MT-HTP</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Maximum liquid temperature</td>
			<td>300 &deg;C</td>
			<td>350 &deg;C</td>
		</tr>
		<tr>
			<td>Flow</td>
			<td>3.2&ndash;100 m&sup3;/h</td>
			<td>3.2&ndash;100 m&sup3;/h</td>
		</tr>
		<tr>
			<td>Head</td>
			<td>20&ndash;80 m</td>
			<td>15&ndash;80 m</td>
		</tr>
		<tr>
			<td>Sizes</td>
			<td>DN32&ndash;DN100</td>
			<td>DN32&ndash;DN100</td>
		</tr>
		<tr>
			<td>Casing material</td>
			<td>Stainless steel 304, 316, 316L</td>
			<td>Stainless steel 304, 316, 316L</td>
		</tr>
		<tr>
			<td>Cooling design</td>
			<td>Multiple internal circulation paths, cooling vanes on the outer magnet rotor, pin coupling to the motor</td>
			<td>External circulation cooling system</td>
		</tr>
		<tr>
			<td>Motor range</td>
			<td>1.5&ndash;55 kW</td>
			<td>1.1&ndash;55 kW</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Choose the rating from the highest temperature the pump can reach, including upsets, not from the normal operating temperature. If the liquid normally runs at 290 &deg;C but can reach 320 &deg;C when a control loop fails, the duty needs the MT-HTP. Never assume a 300 &deg;C pump will survive &quot;short&quot; excursions above its rating. The parts that set the limit, the magnets, bearings and gaskets, do not recover when the temperature falls.</p>

<div class="sj-gallery sj-g3">
<figure><a href="https://www.shinjopump.com/cqb-g-high-temp-magnetic-drive-pump-temperature-up-to-300.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic%20Drive%20Pumps/cqb-g-high-temp-magnetic-drive-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/deb66f855c215419af671a7e8b3ecb9d/cqb-g-high-temp-magnetic-drive-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/deb66f855c215419af671a7e8b3ecb9d/cqb-g-high-temp-magnetic-drive-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo CQB-G high temperature magnetic drive pump rated to 300 °C" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo CQB-G high temperature magnetic drive pump rated to 300 °C' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>CQB-G, up to 300 &deg;C</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/mt-htp-high-temp-magnetic-drive-pump-temperature-up-to-350.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic%20Drive%20Pumps/mt-htp-high-temp-magnetic-drive-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/1c395a40861a55979790f45caacf9876/mt-htp-high-temp-magnetic-drive-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/1c395a40861a55979790f45caacf9876/mt-htp-high-temp-magnetic-drive-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo MT-HTP high temperature magnetic drive pump rated to 350 °C" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo MT-HTP high temperature magnetic drive pump rated to 350 °C' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>MT-HTP, up to 350 &deg;C</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/lqry-thermal-oil-pump-heat-conductive-hot-oil-pump.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Oil%20Pumps/lqry-thermal-oil-pump-heat-conductive-hot-oil-pump-pic.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Oil Pumps/resize/b06715ad433983d0b3cc29fa20537286/lqry-thermal-oil-pump-heat-conductive-hot-oil-pump-pic-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Oil Pumps/resize/b06715ad433983d0b3cc29fa20537286/lqry-thermal-oil-pump-heat-conductive-hot-oil-pump-pic-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo LQRY thermal oil pump for hot oil up to 350 °C" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo LQRY thermal oil pump for hot oil up to 350 °C' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>LQRY hot oil pump, sealed</figcaption>
</figure>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="why-the-magnets-set-the-limit--1">Why the Magnets Set the Limit</h2><a class="header-anchor" href="#why-the-magnets-set-the-limit--1" title="Why the Magnets Set the Limit" aria-label="Why the Magnets Set the Limit"></a></div>

<p>The liquid temperature and the magnet temperature are not the same thing, and the magnets usually set the real limit. Typical operating ranges are 150&ndash;220 &deg;C for high-temperature neodymium magnets and 250&ndash;350 &deg;C for samarium-cobalt magnets. A coupling that pumps a 350 &deg;C liquid therefore has to keep its magnets well below the liquid temperature.</p>

<p>Heat reaches the magnets in three ways: by conduction through the casing, from the liquid circulating inside the pump, and from eddy currents in the metal containment shell, which add heat of their own. Overheated magnets lose torque. Above their limit, the loss becomes permanent, and the coupling slips under load.</p>

<p>That is why the cooling design matters as much as the temperature rating. On the CQB-G, cooling vanes on the outer magnet rotor and several internal circulation paths carry heat away from the magnets. The MT-HTP uses an external circulation cooling system. In both cases, the cooling only works if air can reach the bearing frame and coupling housing. Do not cover them with insulation, even if the rest of the pump is insulated.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="check-npsh-at-the-hottest-condition--2">Check NPSH at the Hottest Condition</h2><a class="header-anchor" href="#check-npsh-at-the-hottest-condition--2" title="Check NPSH at the Hottest Condition" aria-label="Check NPSH at the Hottest Condition"></a></div>

<p>Vapor pressure rises steeply with temperature. Some heat transfer fluids are used above their atmospheric boiling point. For example, the common diphenyl/diphenyl oxide fluids boil at about 257 &deg;C at atmospheric pressure. At 300 &deg;C or more, such a system must be pressurized, usually through the expansion tank, or the liquid flashes at the pump suction.</p>

<p>Calculate NPSH available at the highest temperature and the lowest system pressure, using absolute pressures and the vapor pressure of the actual fluid. Compare it with the pump&#39;s NPSH required: 3.2&ndash;4.5 m across the CQB-G range. Then leave margin. A magnetic drive pump also needs liquid to stay liquid inside the pump, in the passages around the shell and bearings, where the eddy-current heat raises its temperature further. If it flashes there, the bearings run dry even though the pump still delivers flow.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="size-the-coupling-for-the-cold-start--3">Size the Coupling for the Cold Start</h2><a class="header-anchor" href="#size-the-coupling-for-the-cold-start--3" title="Size the Coupling for the Cold Start" aria-label="Size the Coupling for the Cold Start"></a></div>

<p>Thermal oils are many times more viscous cold than hot. At start-up the pump has to turn a thick liquid, so the torque demand can be far higher than at operating temperature. If the magnetic coupling is sized only for hot duty, it slips at a cold start. A slipping coupling heats its own magnets and can damage them before the system ever reaches temperature.</p>

<p>Give the supplier the viscosity at the coldest start-up temperature as well as at operating temperature. The motor and the coupling must both handle the cold case. Alternatively, preheat the loop, or start at reduced speed through a variable-frequency drive until the oil thins.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="warm-up-and-cool-down-slowly--4">Warm Up and Cool Down Slowly</h2><a class="header-anchor" href="#warm-up-and-cool-down-slowly--4" title="Warm Up and Cool Down Slowly" aria-label="Warm Up and Cool Down Slowly"></a></div>

<p>Hot liquid hitting a cold pump, or cold liquid hitting a hot one, causes uneven expansion. The containment shell, the close-clearance silicon carbide bearings and the casing gaskets suffer most. Bring the pump up to temperature with the system, and do not flush a hot pump with cold liquid.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="pressure-ratings-fall-as-temperature-rises--5">Pressure Ratings Fall as Temperature Rises</h2><a class="header-anchor" href="#pressure-ratings-fall-as-temperature-rises--5" title="Pressure Ratings Fall as Temperature Rises" aria-label="Pressure Ratings Fall as Temperature Rises"></a></div>

<p>Metals lose strength when hot, so the allowable pressure of flanges, casings and containment shells falls as temperature rises. A Class 150 flange holds roughly half as much pressure at 300 &deg;C as at ambient temperature. Work out the highest discharge pressure, which is suction pressure plus the pump&#39;s shut-off head, and check it against the casing and shell rating at the maximum temperature, not at 20 &deg;C.</p>

<p>Piping loads also grow with temperature. Thermal expansion of the connected pipework can push the pump out of alignment or overload its nozzles. Support the pipes independently, and do not pull them into place with the flange bolts.</p>

<div class="sj-warn">
<div class="sj-warn-title">Red lines for hot magnetic drive pumps</div>

<ul>
	<li><b>Never exceed the rated temperature</b>, not even briefly. Magnet damage above the limit does not reverse.</li>
	<li><b>Never run dry or against a closed valve.</b> The bearings and the shell overheat within minutes.</li>
	<li><b>Do not insulate the bearing frame or coupling housing.</b> They need air to shed heat.</li>
	<li><b>No cold start on thick oil</b> unless the coupling is sized for it. Preheat, or start slowly.</li>
	<li><b>No thermal shock.</b> Warm up and cool down with the system.</li>
</ul>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="sealless-pump-or-sealed-hot-oil-pump--6">Sealless Pump or Sealed Hot Oil Pump?</h2><a class="header-anchor" href="#sealless-pump-or-sealed-hot-oil-pump--6" title="Sealless Pump or Sealed Hot Oil Pump?" aria-label="Sealless Pump or Sealed Hot Oil Pump?"></a></div>

<p>A magnetic drive pump is the right choice when no leakage is acceptable, as with toxic, flammable or valuable hot liquids. For hot thermal oil in a heating loop, where a small weep from a seal is acceptable and larger flows are needed, the <a href="https://www.shinjopump.com/lqry-thermal-oil-pump-heat-conductive-hot-oil-pump.html">LQRY thermal oil pump</a> is simpler and covers a wider range.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>&nbsp;</th>
			<th>CQB-G / MT-HTP magnetic drive</th>
			<th>LQRY thermal oil pump</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Maximum liquid temperature</td>
			<td>300 &deg;C / 350 &deg;C</td>
			<td>350 &deg;C</td>
		</tr>
		<tr>
			<td>Shaft sealing</td>
			<td>None (sealless)</td>
			<td>Shaft seal ring, mechanical seal or carbon seal</td>
		</tr>
		<tr>
			<td>Flow</td>
			<td>3.2&ndash;100 m&sup3;/h</td>
			<td>4.5&ndash;400 m&sup3;/h</td>
		</tr>
		<tr>
			<td>Maximum head</td>
			<td>80 m</td>
			<td>85 m</td>
		</tr>
		<tr>
			<td>Casing</td>
			<td>Stainless steel</td>
			<td>Cast steel</td>
		</tr>
		<tr>
			<td>Best for</td>
			<td>Toxic, flammable or valuable hot liquids</td>
			<td>Thermal oil heating loops and larger flows</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Both need a clean liquid. Aged thermal oil carries carbon and sludge, which wear the bearings of a magnetic drive pump. Filter the loop, and replace degraded oil before it damages the pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-to-send-with-your-enquiry--7">What to Send with Your Enquiry</h2><a class="header-anchor" href="#what-to-send-with-your-enquiry--7" title="What to Send with Your Enquiry" aria-label="What to Send with Your Enquiry"></a></div>

<ul>
	<li>The liquid, its grade, and its vapor pressure and viscosity at both start-up and operating temperature.</li>
	<li>Normal temperature, maximum temperature, and how long any upset lasts.</li>
	<li>Flow, head and system pressure, including how the system is pressurized.</li>
	<li>NPSH available at the hottest condition.</li>
	<li>Ambient temperature and the cooling utilities available.</li>
	<li>Start-up procedure, including whether the loop is preheated.</li>
	<li>Hazardous-area classification.</li>
</ul>

<p class="sj-cta">Pumping a hot liquid above 200 &deg;C? Send the details to SHINJO and we will <a href="https://www.shinjopump.com/contact.html">confirm the right high temperature model</a> and coupling for your duty. See the full range of <a href="https://www.shinjopump.com/magnetic-drive-pumps.html">magnetic drive pumps</a>, or read <a href="https://www.shinjopump.com/news/the-selection-principle-and-precautions-for-magnetic-drive-pumps.html">how to select a magnetic drive pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="faq--8">FAQ</h2><a class="header-anchor" href="#faq--8" title="FAQ" aria-label="FAQ"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-300-deg-c-magnetic-drive-pump-handle-short-excursions-to-350-deg-c--9">Can a 300 &deg;C magnetic drive pump handle short excursions to 350 &deg;C?</h3><a class="header-anchor" href="#can-a-300-deg-c-magnetic-drive-pump-handle-short-excursions-to-350-deg-c--9" title="Can a 300 &deg;C magnetic drive pump handle short excursions to 350 &deg;C?" aria-label="Can a 300 &deg;C magnetic drive pump handle short excursions to 350 &deg;C?"></a></div>

<p>No. Magnets, bearings and gaskets can be damaged permanently above their rating, even briefly. If the liquid can reach 350 &deg;C in any operating state, specify a pump rated for 350 &deg;C, such as the MT-HTP.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="what-magnets-are-used-in-high-temperature-magnetic-drive-pumps--10">What magnets are used in high temperature magnetic drive pumps?</h3><a class="header-anchor" href="#what-magnets-are-used-in-high-temperature-magnetic-drive-pumps--10" title="What magnets are used in high temperature magnetic drive pumps?" aria-label="What magnets are used in high temperature magnetic drive pumps?"></a></div>

<p>Samarium-cobalt magnets are typically used at high temperature because they work at about 250&ndash;350 &deg;C. Neodymium magnets are stronger but typically limited to about 150&ndash;220 &deg;C even in high-temperature grades. The cooling design must still keep the magnets below the liquid temperature.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="does-a-high-temperature-magnetic-drive-pump-need-cooling-water--11">Does a high temperature magnetic drive pump need cooling water?</h3><a class="header-anchor" href="#does-a-high-temperature-magnetic-drive-pump-need-cooling-water--11" title="Does a high temperature magnetic drive pump need cooling water?" aria-label="Does a high temperature magnetic drive pump need cooling water?"></a></div>

<p>It depends on the design. The CQB-G cools itself through internal circulation paths and cooling vanes on the outer magnet rotor. The MT-HTP uses an external circulation cooling system. Ask which utilities the quoted model requires and what happens if they fail.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-magnetic-drive-pump-handle-thermal-oil--12">Can a magnetic drive pump handle thermal oil?</h3><a class="header-anchor" href="#can-a-magnetic-drive-pump-handle-thermal-oil--12" title="Can a magnetic drive pump handle thermal oil?" aria-label="Can a magnetic drive pump handle thermal oil?"></a></div>

<p>Yes, if the oil is clean and the pump is rated for its maximum temperature. Check NPSH at the hottest condition and size the coupling for cold-start viscosity. For large heating loops where a small seal leak is acceptable, a sealed thermal oil pump is often the simpler choice.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="why-does-my-hot-magnetic-drive-pump-decouple-at-start-up--13">Why does my hot magnetic drive pump decouple at start-up?</h3><a class="header-anchor" href="#why-does-my-hot-magnetic-drive-pump-decouple-at-start-up--13" title="Why does my hot magnetic drive pump decouple at start-up?" aria-label="Why does my hot magnetic drive pump decouple at start-up?"></a></div>

<p>Usually because the oil is too viscous when cold and the coupling torque is too low for that condition. Preheat the loop, start at reduced speed, or ask for a stronger coupling. Do not keep restarting a slipping pump, because each slip heats the magnets.</p>
</div>
</div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>Magnetic Drive Pump vs Canned Motor Pump: Which to Choose</title>
      <description><![CDATA[Magnetic drive pump vs canned motor pump: how each removes the shaft seal, heat and efficiency, dry-running risk, repair, and when to choose each design.]]></description>
      <pubDate>Sun, 11 Oct 2026 11:57:09 +0000</pubDate>
      <link>https://www.shinjopump.com/news/magnetic-drive-pump-vs-canned-motor-pump.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/magnetic-drive-pump-vs-canned-motor-pump.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content">
<div class="sj-article">
<p class="sj-lead">A magnetic drive pump and a canned motor pump both remove the shaft seal, the most common leak path in a centrifugal pump. The difference is how they drive the impeller. A magnetic drive pump uses a standard motor and turns the impeller through a magnetic coupling, across a sealed containment shell. A canned motor pump puts the motor rotor inside the liquid, behind a thin can that protects the stator windings. For most chemical transfer, a magnetic drive pump is easier to own because the motor is standard and the pump can be repaired on site. A canned motor pump is more compact and suits clean liquids in closed loops, but it usually needs specialist repair.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="how-each-design-removes-the-shaft-seal--0">How Each Design Removes the Shaft Seal</h2><a class="header-anchor" href="#how-each-design-removes-the-shaft-seal--0" title="How Each Design Removes the Shaft Seal" aria-label="How Each Design Removes the Shaft Seal"></a></div>

<p><strong>Magnetic drive pump.</strong> An outer magnet rotor sits on the motor shaft. An inner magnet rotor is fixed to the impeller shaft. Between them is a stationary containment shell, also called an isolation sleeve, that closes off the liquid completely. The magnetic field passes through the shell and turns the impeller without any contact, so no shaft passes through the pressure boundary. The impeller runs on sleeve bearings lubricated by the pumped liquid.</p>

<p><strong>Canned motor pump.</strong> The pump and motor form one sealed unit on a common shaft. The motor rotor turns in the pumped liquid, and a thin corrosion-resistant liner, the &quot;can&quot;, separates the liquid from the stator windings. Some of the liquid circulates through the motor to cool it and to lubricate the sleeve bearings. There is no coupling and no separate motor.</p>

<p>Both are sealless designs. Static joints such as casing gaskets and flanges remain, so &quot;zero leakage&quot; means no leakage at the shaft, not that the installation can never leak.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="magnetic-drive-vs-canned-motor-side-by-side--1">Magnetic Drive vs Canned Motor: Side-by-Side</h2><a class="header-anchor" href="#magnetic-drive-vs-canned-motor-side-by-side--1" title="Magnetic Drive vs Canned Motor: Side-by-Side" aria-label="Magnetic Drive vs Canned Motor: Side-by-Side"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>&nbsp;</th>
			<th>Magnetic drive pump</th>
			<th>Canned motor pump</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Motor</td>
			<td>Standard motor, including off-the-shelf explosion-proof versions</td>
			<td>Special motor built into the pump</td>
		</tr>
		<tr>
			<td>Pressure barrier</td>
			<td>Stationary containment shell</td>
			<td>Stator can; in many designs the motor housing is a second barrier</td>
		</tr>
		<tr>
			<td>Heat added to the liquid</td>
			<td>Eddy-current heat from a metal shell; almost none from a plastic or ceramic shell</td>
			<td>Motor and can losses heat the liquid circulating through the motor</td>
		</tr>
		<tr>
			<td>Bearing monitoring</td>
			<td>Recommended</td>
			<td>Essential: worn bearings let the rotor touch the can and damage the windings</td>
		</tr>
		<tr>
			<td>Repair</td>
			<td>Motor swapped on site; wet end usually repaired on site</td>
			<td>Usually returned to the manufacturer or an approved shop</td>
		</tr>
		<tr>
			<td>Footprint</td>
			<td>Longer, because of the separate motor</td>
			<td>Compact, with no coupling; can be mounted in the pipeline</td>
		</tr>
		<tr>
			<td>Changing the duty</td>
			<td>Impeller or coupling can often be changed</td>
			<td>Tied more closely to the original design duty</td>
		</tr>
		<tr>
			<td>Standard</td>
			<td>API 685 covers both sealless designs</td>
			<td>API 685 covers both sealless designs</td>
		</tr>
	</tbody>
</table></div>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="heat-the-hidden-load-in-every-sealless-pump--2">Heat: The Hidden Load in Every Sealless Pump</h2><a class="header-anchor" href="#heat-the-hidden-load-in-every-sealless-pump--2" title="Heat: The Hidden Load in Every Sealless Pump" aria-label="Heat: The Hidden Load in Every Sealless Pump"></a></div>

<p>A metal containment shell sits in a rotating magnetic field, so eddy currents flow in it and turn into heat. That heat is carried away by the liquid flowing through the inside of the pump. Ceramic shell suppliers report that switching from a metal shell to a non-conductive one cuts power input by 10&ndash;15%. That figure gives an idea of the loss in a metal shell. Hastelloy is a common metal choice because its low electrical conductivity keeps the loss down.</p>

<p>The heat matters most for liquids close to their boiling point. As an example, take a 15 kW pump on toluene. Here 10&ndash;15% is 1.5&ndash;2.3 kW. If only 1 m&sup3;/h of liquid circulates past the shell and bearings, the liquid there warms by about 4&ndash;5.5 &deg;C:</p>

<p class="sj-formula">&Delta;T = P &divide; (ṁ &times; c<sub>p</sub>) = 1.5 kW &divide; (0.24 kg/s &times; 1.7 kJ/kg&middot;K) &asymp; 3.7 &deg;C</p>

<p>If that pushes the liquid above its boiling point at the local pressure, it flashes to vapor in the bearing passages and the bearings run dry. A canned motor pump has the same problem with motor heat. For volatile liquids, ask the supplier for the temperature rise in the internal circulation and the margin above vapor pressure.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="dry-running-solids-and-gas--3">Dry Running, Solids and Gas</h2><a class="header-anchor" href="#dry-running-solids-and-gas--3" title="Dry Running, Solids and Gas" aria-label="Dry Running, Solids and Gas"></a></div>

<p>Both designs depend on the pumped liquid to lubricate and cool their bearings. That gives them the same three weaknesses.</p>

<ul>
	<li><strong>Dry running.</strong> Without liquid, the bearings overheat in minutes. A magnetic drive pump also loses cooling at the shell, and overheated magnets lose strength.</li>
	<li><strong>Solids.</strong> Abrasive particles wear the bearings and can block the small internal circulation passages. Sealless pumps need clean liquids.</li>
	<li><strong>Gas.</strong> Entrained gas or vapor breaks the liquid film in the bearings.</li>
</ul>

<p>The best protection is a motor power monitor, which detects dry running, a closed valve and a decoupled magnetic drive. A temperature sensor at the containment shell and a low-level or flow switch add further protection.</p>

<div class="sj-warn">
<div class="sj-warn-title">Red lines for any sealless pump</div>

<ul>
	<li><b>Never run dry</b>, not even for a short test. Fill and vent the casing before starting.</li>
	<li><b>Never run against a closed discharge valve.</b> The trapped liquid heats up quickly.</li>
	<li><b>Keep above minimum flow</b> so the internal circulation can carry the heat away.</li>
	<li><b>Keep solids out.</b> Fit a suction strainer where particles are possible, and keep it clean.</li>
</ul>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="shinjo-39-s-sealless-pump-range--4">Shinjo&#39;s Sealless Pump Range</h2><a class="header-anchor" href="#shinjo-39-s-sealless-pump-range--4" title="Shinjo&#39;s Sealless Pump Range" aria-label="Shinjo&#39;s Sealless Pump Range"></a></div>

<p>Shinjo builds both types, but they serve different jobs.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Pump</th>
			<th>Type</th>
			<th>Wetted material</th>
			<th>Flow</th>
			<th>Head</th>
			<th>Liquid temperature</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td><a href="https://www.shinjopump.com/cq-magnetic-drive-pump-material-stainless-steel-304-316.html">CQ</a></td>
			<td>Magnetic drive</td>
			<td>Stainless steel 304, 316, 316L</td>
			<td>Up to 60 m&sup3;/h</td>
			<td>5&ndash;50 m</td>
			<td>Up to 80 &deg;C, 200 &deg;C on request</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/cqb-f-teflon-lining-magnetic-drive-pump-corrosion-resistant-pump.html">CQB-F</a></td>
			<td>Magnetic drive</td>
			<td>Fluoroplastic lining</td>
			<td>1.8&ndash;100 m&sup3;/h</td>
			<td>8&ndash;32 m</td>
			<td>Up to 80 &deg;C</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/cqf-engineering-plastic-magnetic-drive-pump-material-polypropylene-pp.html">CQF</a></td>
			<td>Magnetic drive</td>
			<td>Polypropylene</td>
			<td>1&ndash;25 m&sup3;/h</td>
			<td>3&ndash;32 m</td>
			<td>Up to 60 &deg;C</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/zcq-self-priming-magnetic-drive-pump-head-12-50-m.html">ZCQ</a></td>
			<td>Self-priming magnetic drive</td>
			<td>Stainless steel 304, 316, 316L</td>
			<td>3&ndash;60 m&sup3;/h</td>
			<td>12&ndash;50 m</td>
			<td>Up to 80 &deg;C</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/zbf-self-priming-plastic-magnetic-drive-pump-suction-head-5-meters.html">ZBF</a></td>
			<td>Self-priming magnetic drive</td>
			<td>Polypropylene</td>
			<td>6.5&ndash;12.5 m&sup3;/h</td>
			<td>10&ndash;32 m</td>
			<td>Up to 80 &deg;C</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/cqb-g-high-temp-magnetic-drive-pump-temperature-up-to-300.html">CQB-G</a> and <a href="https://www.shinjopump.com/mt-htp-high-temp-magnetic-drive-pump-temperature-up-to-350.html">MT-HTP</a></td>
			<td>High-temperature magnetic drive</td>
			<td>Stainless steel 304, 316, 316L</td>
			<td>3.2&ndash;100 m&sup3;/h</td>
			<td>15&ndash;80 m</td>
			<td>Up to 300 &deg;C and 350 &deg;C</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/pbg-vertical-canned-motor-centrifugal-pump-capacity-6-3-1080-m3-h.html">PBG</a></td>
			<td>Canned motor</td>
			<td>Cast iron</td>
			<td>6.3&ndash;1080 m&sup3;/h</td>
			<td>12.5&ndash;125 m</td>
			<td>Up to 90 &deg;C, clean water</td>
		</tr>
	</tbody>
</table></div>
</div>

<div class="sj-gallery">
<figure><a href="https://www.shinjopump.com/cq-magnetic-drive-pump-material-stainless-steel-304-316.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic%20Drive%20Pumps/cq-magnetic-drive-pump-ss.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/c7b47889c1bd39a0b996a93a1619e806/cq-magnetic-drive-pump-ss-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/c7b47889c1bd39a0b996a93a1619e806/cq-magnetic-drive-pump-ss-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo CQ stainless steel magnetic drive pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo CQ stainless steel magnetic drive pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>CQ magnetic drive</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/cqb-f-teflon-lining-magnetic-drive-pump-corrosion-resistant-pump.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic%20Drive%20Pumps/cqb-f-teflon-lining-magnetic-drive-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/02a1b4dc23141d77218a7ef6d254010d/cqb-f-teflon-lining-magnetic-drive-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/02a1b4dc23141d77218a7ef6d254010d/cqb-f-teflon-lining-magnetic-drive-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo CQB-F fluoroplastic-lined magnetic drive pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo CQB-F fluoroplastic-lined magnetic drive pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>CQB-F, lined</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/zcq-self-priming-magnetic-drive-pump-head-12-50-m.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic%20Drive%20Pumps/zcq-self-priming-magnetic-drive-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/0d04acfde2f34c2cba540fe70d9c8321/zcq-self-priming-magnetic-drive-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/0d04acfde2f34c2cba540fe70d9c8321/zcq-self-priming-magnetic-drive-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo ZCQ self-priming magnetic drive pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo ZCQ self-priming magnetic drive pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>ZCQ, self-priming</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/pbg-vertical-canned-motor-centrifugal-pump-capacity-6-3-1080-m3-h.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal%20Pumps/pbg-vertical-canned-motor-centrifugal-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/e0ea6af6a9d6790a3c8fa4d9c537f063/pbg-vertical-canned-motor-centrifugal-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/e0ea6af6a9d6790a3c8fa4d9c537f063/pbg-vertical-canned-motor-centrifugal-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo PBG vertical canned motor centrifugal pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo PBG vertical canned motor centrifugal pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>PBG canned motor</figcaption>
</figure>
</div>

<p>The PBG canned motor pump is designed for clean water: HVAC circulation, booster sets, fire pressurization and hot and cold water loops. It mounts directly in a horizontal or vertical pipe. Because it never draws in air, it also suits vacuum systems. For corrosive, toxic or flammable chemicals, Shinjo supplies magnetic drive pumps, with the wetted material matched to the liquid.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="when-to-choose-each--5">When to Choose Each</h2><a class="header-anchor" href="#when-to-choose-each--5" title="When to Choose Each" aria-label="When to Choose Each"></a></div>

<p><strong>Choose a magnetic drive pump when:</strong></p>

<ul>
	<li>You want a standard or explosion-proof motor that your site can replace.</li>
	<li>Maintenance will be done on site.</li>
	<li>The liquid needs a lined or plastic wet end, such as acids and chlorides.</li>
	<li>The duty may change later.</li>
	<li>The pump must lift from below, which the self-priming ZCQ and ZBF can do.</li>
</ul>

<p><strong>Choose a canned motor pump when:</strong></p>

<ul>
	<li>The liquid is clean water or a similar clean liquid in a closed loop.</li>
	<li>Space is tight or the pump has to sit in the pipeline.</li>
	<li>Low noise matters, as in buildings.</li>
</ul>

<p><strong>Choose neither when</strong> the liquid carries solids, the pump may run dry often, or the viscosity is high. In those cases, a sealed pump with a double mechanical seal or an <a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html">air-operated diaphragm pump</a> is more reliable. For sizing details on magnetic drive pumps, see <a href="https://www.shinjopump.com/news/the-selection-principle-and-precautions-for-magnetic-drive-pumps.html">how to select a magnetic drive pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-to-send-with-your-enquiry--6">What to Send with Your Enquiry</h2><a class="header-anchor" href="#what-to-send-with-your-enquiry--6" title="What to Send with Your Enquiry" aria-label="What to Send with Your Enquiry"></a></div>

<ul>
	<li>The liquid, its concentration, density, viscosity and vapor pressure at operating temperature.</li>
	<li>Normal and maximum temperature.</li>
	<li>Flow, head and suction conditions, including whether the pump must self-prime.</li>
	<li>Solids content, if any.</li>
	<li>Hazardous-area classification and the motor protection required.</li>
	<li>Whether secondary containment or leak detection is required.</li>
</ul>

<p class="sj-cta">Comparing sealless options for a chemical duty? Send the details to SHINJO and we will <a href="https://www.shinjopump.com/contact.html">recommend a magnetic drive pump</a> with the right material and coupling. See the full range of <a href="https://www.shinjopump.com/magnetic-drive-pumps.html">magnetic drive pumps</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="faq--7">FAQ</h2><a class="header-anchor" href="#faq--7" title="FAQ" aria-label="FAQ"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="is-a-magnetic-drive-pump-more-efficient-than-a-canned-motor-pump--8">Is a magnetic drive pump more efficient than a canned motor pump?</h3><a class="header-anchor" href="#is-a-magnetic-drive-pump-more-efficient-than-a-canned-motor-pump--8" title="Is a magnetic drive pump more efficient than a canned motor pump?" aria-label="Is a magnetic drive pump more efficient than a canned motor pump?"></a></div>

<p>It depends on the design. A metal containment shell can cost around 10&ndash;15% of input power in eddy-current losses, while a plastic or ceramic shell avoids most of that. Canned motors lose power in the can and the motor. Compare the absorbed power each supplier quotes at your duty point.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-magnetic-drive-or-canned-motor-pump-run-dry--9">Can a magnetic drive or canned motor pump run dry?</h3><a class="header-anchor" href="#can-a-magnetic-drive-or-canned-motor-pump-run-dry--9" title="Can a magnetic drive or canned motor pump run dry?" aria-label="Can a magnetic drive or canned motor pump run dry?"></a></div>

<p>No. Both rely on the pumped liquid to lubricate and cool their bearings, and dry running can destroy the bearings within minutes. Fit a power monitor or flow switch that stops the pump when it loses liquid.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="which-is-better-for-hazardous-chemicals--10">Which is better for hazardous chemicals?</h3><a class="header-anchor" href="#which-is-better-for-hazardous-chemicals--10" title="Which is better for hazardous chemicals?" aria-label="Which is better for hazardous chemicals?"></a></div>

<p>Both remove the shaft seal. A magnetic drive pump is easier to maintain because it uses a standard motor. A canned motor pump often provides a second containment barrier in the motor housing. Specify the containment and leak detection you need, and compare the offers against that.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="does-shinjo-supply-canned-motor-pumps-for-chemicals--11">Does Shinjo supply canned motor pumps for chemicals?</h3><a class="header-anchor" href="#does-shinjo-supply-canned-motor-pumps-for-chemicals--11" title="Does Shinjo supply canned motor pumps for chemicals?" aria-label="Does Shinjo supply canned motor pumps for chemicals?"></a></div>

<p>Shinjo&#39;s PBG canned motor pump is a cast iron design for clean water up to 90 &deg;C. For chemicals, we recommend a magnetic drive pump in stainless steel, fluoroplastic lining or polypropylene, depending on the liquid.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="what-standard-covers-sealless-pumps--12">What standard covers sealless pumps?</h3><a class="header-anchor" href="#what-standard-covers-sealless-pumps--12" title="What standard covers sealless pumps?" aria-label="What standard covers sealless pumps?"></a></div>

<p>API 685 covers sealless centrifugal pumps, both magnetic drive and canned motor, for petroleum, petrochemical and gas industry service. Many general chemical duties do not require it. If your project does, state it in the enquiry.</p>
</div>
</div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>PTFE-Lined Pump vs Stainless Steel Pump: How to Choose</title>
      <description><![CDATA[PTFE-lined pump or stainless steel pump? Which suits HCl, sulfuric acid, brine and solvents, where each fails, and how Shinjo IHF, CQB-F and IH compare.]]></description>
      <pubDate>Sun, 11 Oct 2026 11:57:23 +0000</pubDate>
      <link>https://www.shinjopump.com/news/ptfe-lined-pump-vs-stainless-steel-pump.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/ptfe-lined-pump-vs-stainless-steel-pump.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content">
<div class="sj-article">
<p class="sj-lead">Choose a PTFE-lined pump when the liquid attacks stainless steel: hydrochloric acid, hydrofluoric acid, dilute sulfuric acid, aqua regia, mixed acids and strong oxidizers. Choose a stainless steel pump when the liquid stays within the resistance of the grade and the duty is hotter, higher in head or pressure, or carries solids. In Shinjo&#39;s range, that means the <a href="https://www.shinjopump.com/ihf-fluorine-plastic-lining-centrifugal-pump-teflon-lined-pump.html">IHF lined centrifugal pump</a> (up to 80 &deg;C and 87 m) or the sealless CQB-F on one side, and the <a href="https://www.shinjopump.com/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion.html">IH stainless steel chemical pump</a> (up to 150 &deg;C, 132 m and 1.6 MPa) on the other.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="which-pump-for-which-liquid--0">Which Pump for Which Liquid?</h2><a class="header-anchor" href="#which-pump-for-which-liquid--0" title="Which Pump for Which Liquid?" aria-label="Which Pump for Which Liquid?"></a></div>

<p>Start with the liquid. For many common chemicals, one of the two options is ruled out before flow and head are even considered.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Liquid</th>
			<th>Stainless steel pump</th>
			<th>PTFE-lined pump</th>
			<th>Usual choice</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Hydrochloric acid, any strength</td>
			<td>Not resistant: 304 and 316 are attacked at any concentration</td>
			<td>Resistant</td>
			<td>Lined</td>
		</tr>
		<tr>
			<td>Hydrofluoric acid</td>
			<td>Attacked</td>
			<td>Resistant</td>
			<td>Lined</td>
		</tr>
		<tr>
			<td>Sulfuric acid, 5&ndash;80%</td>
			<td>Attacked; 316 is only usable below about 5% or above 95% at low temperature</td>
			<td>Resistant</td>
			<td>Lined</td>
		</tr>
		<tr>
			<td>Nitric acid</td>
			<td>304L and 316L are widely used</td>
			<td>Resistant</td>
			<td>Either; stainless steel for higher temperature or head</td>
		</tr>
		<tr>
			<td>Sodium hydroxide</td>
			<td>Suitable at moderate temperature</td>
			<td>Resistant</td>
			<td>Either</td>
		</tr>
		<tr>
			<td>Brine and seawater</td>
			<td>316L is limited to about 1,000 ppm chloride</td>
			<td>Resistant</td>
			<td>Lined, or duplex steel for high head or solids</td>
		</tr>
		<tr>
			<td>Organic solvents and oils</td>
			<td>Usually suitable</td>
			<td>Usually resistant, but some solvents permeate fluoroplastics</td>
			<td>Stainless steel</td>
		</tr>
		<tr>
			<td>Liquids with hard or abrasive solids</td>
			<td>Suitable grades tolerate moderate solids</td>
			<td>Hard particles cut the lining</td>
			<td>Stainless or duplex steel</td>
		</tr>
		<tr>
			<td>Any liquid above 80 &deg;C</td>
			<td>IH pump is rated to 150 &deg;C</td>
			<td>Above the published rating</td>
			<td>Stainless steel or alloy</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>For 98% sulfuric acid, where cast iron is also an option, see our guide to the <a href="https://www.shinjopump.com/news/concentrated-sulfuric-acid-pump.html">concentrated sulfuric acid pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-quot-ptfe-lined-quot-means-in-a-pump--1">What &quot;PTFE-Lined&quot; Means in a Pump</h2><a class="header-anchor" href="#what-quot-ptfe-lined-quot-means-in-a-pump--1" title="What &quot;PTFE-Lined&quot; Means in a Pump" aria-label="What &quot;PTFE-Lined&quot; Means in a Pump"></a></div>

<p>In the pump trade, &quot;PTFE-lined&quot; and &quot;Teflon-lined&quot; usually mean any fluoroplastic lining: PTFE, FEP (also called F46) or PFA. PTFE cannot be melt-processed, so molded pump linings are usually FEP or PFA, which flow when heated. The IHF is lined with FEP. Its impeller and pump cover are metal inserts with fluoroplastic sintered over them.</p>

<p>The metal casing carries the pressure and the pipe loads, and the lining resists the chemicals. This is why a lined pump can handle hydrochloric acid, hydrofluoric acid, aqua regia, strong alkalis, strong oxidizers and most organic solvents. These are all listed on the IHF product page. Doing the same with solid metal would mean a far more expensive nickel alloy casing.</p>

<p>The fluoroplastics themselves tolerate high temperatures: PFA is rated for continuous service up to 260 &deg;C. The pump&#39;s limit is much lower because the lining is locked into a steel casing, and plastic expands many times more than steel when heated. Heat and rapid temperature changes stress the bond between the two. That is why the published liquid temperature for the IHF and CQB-F is 80 &deg;C.</p>

<p>The IHF uses an external bellows mechanical seal, so the springs and metal parts of the seal sit outside the liquid. The stationary face is 99.9% alumina ceramic or silicon carbide, and the rotating face is filled PTFE or silicon carbide.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="where-stainless-steel-pumps-fail--2">Where Stainless Steel Pumps Fail</h2><a class="header-anchor" href="#where-stainless-steel-pumps-fail--2" title="Where Stainless Steel Pumps Fail" aria-label="Where Stainless Steel Pumps Fail"></a></div>

<p>Stainless steel resists corrosion because of a thin chromium oxide film. Anything that breaks that film down faster than it can reform will corrode the pump, and some chemicals do this from the first day.</p>

<ul>
	<li><strong>Hydrochloric acid.</strong> Standard 304 and 316 are considered non-resistant at any concentration and temperature.</li>
	<li><strong>Chlorides.</strong> A widely used guideline for immersed stainless steel puts the chloride limit at about 200 ppm for 304L, 1,000 ppm for 316L and 3,600 ppm for duplex 2205. Above that, pitting and crevice corrosion start. Crevices, deposits and heat lower these limits.</li>
	<li><strong>Hot chlorides.</strong> Chloride stress corrosion cracking of 304 and 316 is rare below 60 &deg;C but becomes a real risk above it. Duplex grades resist it much better.</li>
	<li><strong>Dilute reducing acids.</strong> Sulfuric acid between about 5% and 80% attacks 316 actively.</li>
</ul>

<p>The grade matters as much as the word &quot;stainless&quot;. The IH pump and the <a href="https://www.shinjopump.com/cq-magnetic-drive-pump-material-stainless-steel-304-316.html">CQ magnetic drive pump</a> are offered in 304, 316 and 316L. For flue gas desulfurization slurry, which combines chlorides, acidity and abrasion, the <a href="https://www.shinjopump.com/cast-steel-desulfurization-pump-single-stage-suction.html">cast steel desulfurization pump</a> uses a duplex (&quot;two-phase&quot;) alloy for the casing and impeller.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="where-ptfe-linings-fail--3">Where PTFE Linings Fail</h2><a class="header-anchor" href="#where-ptfe-linings-fail--3" title="Where PTFE Linings Fail" aria-label="Where PTFE Linings Fail"></a></div>

<p>A lining resists chemicals well. It fails mechanically and thermally, and these failures usually come from operating conditions rather than from the chemical itself.</p>

<ul>
	<li><strong>Heat and thermal cycling.</strong> Running near the top of the range, or heating and cooling the pump quickly, can blister the lining or separate it from the casing. Steam cleaning is a common cause, because steam is well above 80 &deg;C.</li>
	<li><strong>Vacuum.</strong> If the suction can fall below atmospheric pressure, for example when a line drains or siphons, the lining can be pulled away from the casing. Tell the supplier if vacuum is possible.</li>
	<li><strong>Solids and cavitation.</strong> Hard or sharp particles cut and wear the lining, and collapsing cavitation bubbles erode it. Once the metal behind it is exposed, it corrodes quickly.</li>
	<li><strong>Permeation.</strong> Small molecules such as hydrogen chloride, chlorine and bromine slowly diffuse through fluoroplastics. They can condense behind the lining and cause blisters. A thicker lining slows this down.</li>
	<li><strong>Mechanical damage.</strong> Pipe strain, overtightened flanges and careless tools during maintenance all crack linings.</li>
</ul>

<p>Lined pumps also reach lower heads. The IHF goes up to 87 m and the CQB-F up to 32 m, while the IH stainless steel pump reaches 132 m.</p>

<div class="sj-warn">
<div class="sj-warn-title">Five things that destroy a lined pump</div>

<ul>
	<li><b>Steam-out or hot cleaning</b> above the 80 &deg;C rating.</li>
	<li><b>Vacuum in the suction</b> when the system drains or siphons.</li>
	<li><b>Hard solids or cavitation</b> that cut through the lining.</li>
	<li><b>Dry running</b>, especially in a lined magnetic drive pump whose bearings are cooled by the liquid.</li>
	<li><b>Sudden temperature changes</b> such as hot acid entering a cold pump.</li>
</ul>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="shinjo-lined-and-stainless-steel-pumps-compared--4">Shinjo Lined and Stainless Steel Pumps Compared</h2><a class="header-anchor" href="#shinjo-lined-and-stainless-steel-pumps-compared--4" title="Shinjo Lined and Stainless Steel Pumps Compared" aria-label="Shinjo Lined and Stainless Steel Pumps Compared"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Pump</th>
			<th>Construction</th>
			<th>Flow</th>
			<th>Head</th>
			<th>Liquid temperature</th>
			<th>Shaft sealing</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td><a href="https://www.shinjopump.com/ihf-fluorine-plastic-lining-centrifugal-pump-teflon-lined-pump.html">IHF</a></td>
			<td>Metal casing lined with FEP</td>
			<td>3&ndash;130 m&sup3;/h</td>
			<td>5&ndash;87 m</td>
			<td>Up to 80 &deg;C</td>
			<td>External bellows mechanical seal</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/cqb-f-teflon-lining-magnetic-drive-pump-corrosion-resistant-pump.html">CQB-F</a></td>
			<td>Metal casing with fluoroplastic lining, magnetic drive</td>
			<td>1.8&ndash;100 m&sup3;/h</td>
			<td>8&ndash;32 m</td>
			<td>Up to 80 &deg;C</td>
			<td>None (sealless)</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion.html">IH</a></td>
			<td>Stainless steel, back pull-out design</td>
			<td>3.2&ndash;400 m&sup3;/h</td>
			<td>5&ndash;132 m</td>
			<td>&minus;20 to 150 &deg;C</td>
			<td>Mechanical seal</td>
		</tr>
		<tr>
			<td><a href="https://www.shinjopump.com/cq-magnetic-drive-pump-material-stainless-steel-304-316.html">CQ</a></td>
			<td>Stainless steel 304, 316 or 316L, magnetic drive</td>
			<td>Up to 60 m&sup3;/h</td>
			<td>5&ndash;50 m</td>
			<td>Up to 80 &deg;C, 200 &deg;C on request</td>
			<td>None (sealless)</td>
		</tr>
	</tbody>
</table></div>
</div>

<div class="sj-gallery">
<figure><a href="https://www.shinjopump.com/ihf-fluorine-plastic-lining-centrifugal-pump-teflon-lined-pump.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal%20Pumps/ihf-fluorine-plastic-lining-centrifugal-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/344d799a710d67601fb0f1c43fad729b/ihf-fluorine-plastic-lining-centrifugal-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/344d799a710d67601fb0f1c43fad729b/ihf-fluorine-plastic-lining-centrifugal-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo IHF PTFE-lined centrifugal pump with FEP lining" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo IHF PTFE-lined centrifugal pump with FEP lining' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>IHF, FEP-lined</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/cqb-f-teflon-lining-magnetic-drive-pump-corrosion-resistant-pump.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic%20Drive%20Pumps/cqb-f-teflon-lining-magnetic-drive-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/02a1b4dc23141d77218a7ef6d254010d/cqb-f-teflon-lining-magnetic-drive-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/02a1b4dc23141d77218a7ef6d254010d/cqb-f-teflon-lining-magnetic-drive-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo CQB-F lined magnetic drive pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo CQB-F lined magnetic drive pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>CQB-F, lined, sealless</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Chemical%20Process%20Pumps/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Chemical Process Pumps/resize/a4d5cf8b4164adf36c33037d9e557973/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Chemical Process Pumps/resize/a4d5cf8b4164adf36c33037d9e557973/ih-chemical-stainless-steel-centrifugal-pump-anti-corrosion-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo IH stainless steel chemical centrifugal pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo IH stainless steel chemical centrifugal pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>IH, stainless steel</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/cq-magnetic-drive-pump-material-stainless-steel-304-316.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic%20Drive%20Pumps/cq-magnetic-drive-pump-ss.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/c7b47889c1bd39a0b996a93a1619e806/cq-magnetic-drive-pump-ss-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/c7b47889c1bd39a0b996a93a1619e806/cq-magnetic-drive-pump-ss-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo CQ stainless steel magnetic drive pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo CQ stainless steel magnetic drive pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>CQ, stainless, sealless</figcaption>
</figure>
</div>

<p>The IH has a back pull-out design. The rotating assembly comes out after removing the coupling spacer, without disturbing the casing, piping or motor. That shortens maintenance on a pump that sees regular seal changes.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="sealed-or-sealless--5">Sealed or Sealless?</h2><a class="header-anchor" href="#sealed-or-sealless--5" title="Sealed or Sealless?" aria-label="Sealed or Sealless?"></a></div>

<p>The casing material is only half the decision. If a leak would be dangerous, toxic or costly, choose a magnetic drive pump with no shaft seal: the CQB-F for liquids that need a lining, or the CQ for liquids stainless steel can handle. For cool, mildly corrosive liquids, the <a href="https://www.shinjopump.com/cqf-engineering-plastic-magnetic-drive-pump-material-polypropylene-pp.html">CQF polypropylene magnetic drive pump</a> is a lower-cost option up to 60 &deg;C.</p>

<p>Magnetic drive pumps have their own limits. Their internal bearings are lubricated by the pumped liquid, so they must never run dry, and they need a clean liquid. For more on sizing them, see <a href="https://www.shinjopump.com/news/the-selection-principle-and-precautions-for-magnetic-drive-pumps.html">how to select a magnetic drive pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="compare-the-cost-over-the-pump-39-s-life--6">Compare the Cost Over the Pump&#39;s Life</h2><a class="header-anchor" href="#compare-the-cost-over-the-pump-39-s-life--6" title="Compare the Cost Over the Pump&#39;s Life" aria-label="Compare the Cost Over the Pump&#39;s Life"></a></div>

<p>For hydrochloric acid, the real comparison is not lined pump against 316, because 316 fails. It is lined pump against a nickel alloy such as Hastelloy, and the lined pump is usually much cheaper. For a liquid that stainless steel handles well, a stainless pump avoids every lining risk above and tolerates upsets, solids and hot cleaning. In that case, the lining adds cost without adding life.</p>

<p>Count the failures, not just the purchase price. A lined pump that blisters after every steam-out costs more than a stainless pump in the right grade. A 316 pump that pits through in brine costs more than a lined pump that would have lasted.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-to-send-with-your-enquiry--7">What to Send with Your Enquiry</h2><a class="header-anchor" href="#what-to-send-with-your-enquiry--7" title="What to Send with Your Enquiry" aria-label="What to Send with Your Enquiry"></a></div>

<ul>
	<li>The liquid and its concentration range, including trace chlorides or fluorides.</li>
	<li>Normal and maximum temperature, and any steam or hot-water cleaning.</li>
	<li>Flow, head and suction conditions, including whether vacuum is possible.</li>
	<li>Solids content, particle size and hardness.</li>
	<li>Whether a leak is acceptable, which decides between a sealed and a sealless pump.</li>
	<li>Operating pattern: continuous, batch or frequent starts.</li>
</ul>

<p class="sj-cta">Not sure whether your liquid needs a lining? Send the details to SHINJO and we will <a href="https://www.shinjopump.com/contact.html">recommend a pump and material</a> for your duty. Our full range is in the <a href="https://www.shinjopump.com/chemical-process-pumps.html">chemical process pumps</a> category.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="faq--8">FAQ</h2><a class="header-anchor" href="#faq--8" title="FAQ" aria-label="FAQ"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="is-a-ptfe-lined-pump-the-same-as-a-teflon-lined-pump--9">Is a PTFE-lined pump the same as a Teflon-lined pump?</h3><a class="header-anchor" href="#is-a-ptfe-lined-pump-the-same-as-a-teflon-lined-pump--9" title="Is a PTFE-lined pump the same as a Teflon-lined pump?" aria-label="Is a PTFE-lined pump the same as a Teflon-lined pump?"></a></div>

<p>Yes. Teflon is a brand name for PTFE and related fluoroplastics. In practice, &quot;PTFE-lined&quot; and &quot;Teflon-lined&quot; pumps are often lined with FEP or PFA, which can be molded. The IHF is lined with FEP (F46).</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-ptfe-lined-pump-handle-hydrochloric-acid--10">Can a PTFE-lined pump handle hydrochloric acid?</h3><a class="header-anchor" href="#can-a-ptfe-lined-pump-handle-hydrochloric-acid--10" title="Can a PTFE-lined pump handle hydrochloric acid?" aria-label="Can a PTFE-lined pump handle hydrochloric acid?"></a></div>

<p>Yes. Fluoroplastic linings resist hydrochloric acid at all concentrations within the pump&#39;s temperature rating, while 304 and 316 stainless steel do not. Over time, hydrogen chloride can permeate the lining, so avoid running at the top of the temperature range.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="why-is-a-lined-pump-limited-to-80-deg-c-if-ptfe-can-handle-260-deg-c--11">Why is a lined pump limited to 80 &deg;C if PTFE can handle 260 &deg;C?</h3><a class="header-anchor" href="#why-is-a-lined-pump-limited-to-80-deg-c-if-ptfe-can-handle-260-deg-c--11" title="Why is a lined pump limited to 80 &deg;C if PTFE can handle 260 &deg;C?" aria-label="Why is a lined pump limited to 80 &deg;C if PTFE can handle 260 &deg;C?"></a></div>

<p>The limit protects the bond between the lining and the steel casing. Plastic expands many times more than steel, so heat and rapid temperature changes can blister or loosen the lining long before the plastic itself degrades.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="is-316l-stainless-steel-good-enough-for-seawater--12">Is 316L stainless steel good enough for seawater?</h3><a class="header-anchor" href="#is-316l-stainless-steel-good-enough-for-seawater--12" title="Is 316L stainless steel good enough for seawater?" aria-label="Is 316L stainless steel good enough for seawater?"></a></div>

<p>Usually not. A common guideline limits 316L to about 1,000 ppm chloride, and seawater contains about 19,000 ppm. Use a lined pump, a duplex or super duplex steel, or a plastic pump for seawater and strong brines.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-ptfe-lined-pump-handle-slurry--13">Can a PTFE-lined pump handle slurry?</h3><a class="header-anchor" href="#can-a-ptfe-lined-pump-handle-slurry--13" title="Can a PTFE-lined pump handle slurry?" aria-label="Can a PTFE-lined pump handle slurry?"></a></div>

<p>Only fine, soft solids in low concentration. Hard or sharp particles cut and wear the lining. For corrosive slurries, a duplex steel pump such as the desulfurization pump is usually the better choice.</p>
</div>
</div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>Concentrated Sulfuric Acid Pump: Materials, Types and Sizing</title>
      <description><![CDATA[Choose a pump for concentrated sulfuric acid: concentration and temperature limits for cast iron, carbon steel and lined pumps, motor sizing and seals.]]></description>
      <pubDate>Sun, 11 Oct 2026 11:53:39 +0000</pubDate>
      <link>https://www.shinjopump.com/news/concentrated-sulfuric-acid-pump.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/concentrated-sulfuric-acid-pump.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content">
<div class="sj-article">
<p class="sj-lead">For a concentrated sulfuric acid pump handling 80% to 98% acid at moderate temperature, a centrifugal pump in gray cast iron or carbon steel is the standard and most economical choice. The acid itself forms a protective iron sulfate film on the metal. Below 80%, above 60 &deg;C, or wherever the concentration can drop, that film breaks down, and a fluoroplastic-lined pump is the safer choice. This guide gives the limits for each option, shows how to size the motor for an acid that weighs 1.84 times as much as water, and lists what to put in the purchase order.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="which-concentrated-sulfuric-acid-pump-for-which-duty--0">Which Concentrated Sulfuric Acid Pump for Which Duty?</h2><a class="header-anchor" href="#which-concentrated-sulfuric-acid-pump-for-which-duty--0" title="Which Concentrated Sulfuric Acid Pump for Which Duty?" aria-label="Which Concentrated Sulfuric Acid Pump for Which Duty?"></a></div>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Acid condition</th>
			<th>Pump to consider</th>
			<th>Limits</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>80&ndash;98%, 25&ndash;50 &deg;C</td>
			<td><a href="https://www.shinjopump.com/gbw-concentrated-sulfuric-acid-centrifugal-pump.html">GBW pump</a> in gray cast iron (HT200/HT250)</td>
			<td>Concentration 80&ndash;98%, temperature 25&ndash;50 &deg;C</td>
		</tr>
		<tr>
			<td>80&ndash;98%, 25&ndash;60 &deg;C</td>
			<td>GBW pump in WCB carbon steel</td>
			<td>Concentration 80&ndash;98%, temperature 25&ndash;60 &deg;C</td>
		</tr>
		<tr>
			<td>Below 80%, or a concentration that varies</td>
			<td><a href="https://www.shinjopump.com/ihf-fluorine-plastic-lining-centrifugal-pump-teflon-lined-pump.html">IHF fluoroplastic-lined centrifugal pump</a> or <a href="https://www.shinjopump.com/cqb-f-teflon-lining-magnetic-drive-pump-corrosion-resistant-pump.html">CQB-F lined magnetic drive pump</a></td>
			<td>Up to 80 &deg;C, no thermal shock, motor sized for SG 1.84; magnetic drive must never run dry</td>
		</tr>
		<tr>
			<td>Transfer from a tank or sump</td>
			<td><a href="https://www.shinjopump.com/fluoroplastics-anti-corrosion-submerged-pump-12-28-meters.html">Fluoroplastic submerged pump</a></td>
			<td>6&ndash;50 m&sup3;/h, 12&ndash;28 m head</td>
		</tr>
		<tr>
			<td>Small or intermittent transfer</td>
			<td><a href="https://www.shinjopump.com/double-diaphragm-pump-material-polypropylene-pp-pvdf-ptfe.html">Air-operated diaphragm pump</a>, PTFE version</td>
			<td>Check PP and PVDF versions against the concentration</td>
		</tr>
		<tr>
			<td>Oleum (fuming acid, above 100%)</td>
			<td>Not cast iron; ask us about carbon steel</td>
			<td>See the red lines below</td>
		</tr>
	</tbody>
</table></div>
</div>

<div class="sj-viz sj-viz-conc">
<div class="sj-viz-title">Sulfuric acid concentration and the pump material it allows</div>

<div class="sj-viz-body">
<div class="sj-scale">
<div class="sj-seg sj-seg-a"><span>Below 65%</span></div>

<div class="sj-seg sj-seg-b"><span>65&ndash;80%</span></div>

<div class="sj-seg sj-seg-c"><span>80&ndash;98%</span></div>

<div class="sj-seg sj-seg-d"><span>Oleum</span></div>
</div>

<div class="sj-key-row"><span class="sj-key-t"><b>Below 65%:</b> iron does not resist the acid. Use a fluoroplastic-lined pump.</span></div>

<div class="sj-key-row"><span class="sj-key-t"><b>65&ndash;80%:</b> the most aggressive range for iron. Never use a cast iron or carbon steel pump here.</span></div>

<div class="sj-key-row"><span class="sj-key-t"><b>80&ndash;98%:</b> GBW in gray cast iron up to 50 &deg;C or in WCB carbon steel up to 60 &deg;C, or a lined pump up to 80 &deg;C.</span></div>

<div class="sj-key-row"><span class="sj-key-t"><b>Oleum (above 100%):</b> no cast iron. Carbon steel only for short-term exposure.</span></div>
</div>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="why-iron-works-in-concentrated-acid-and-when-it-stops-working--1">Why Iron Works in Concentrated Acid, and When It Stops Working</h2><a class="header-anchor" href="#why-iron-works-in-concentrated-acid-and-when-it-stops-working--1" title="Why Iron Works in Concentrated Acid, and When It Stops Working" aria-label="Why Iron Works in Concentrated Acid, and When It Stops Working"></a></div>

<p>Concentrated sulfuric acid (sulphuric acid in British English) is a strong oxidizer. When it touches iron or carbon steel, it forms a thin layer of iron sulfate that separates the metal from the acid and slows further attack. That film is what protects a GBW pump. Its gray iron is ordinary HT200 or HT250 without large alloy additions; the protection comes from the acid, not from the alloy.</p>

<p>The film only survives in strong acid. Below 80% it dissolves, and the corrosion rate rises sharply. The range from 65% to 80% is the worst of all for iron. The concentration therefore has to stay above 80% in every operating state, including startup, shutdown, flushing and upsets. For the longest life, keep it at the strong end of the range.</p>

<p>Water is the usual cause of trouble. A water flush, a leaking cooler or moist air drawn into a tank can dilute the acid inside the pump. Dilution also releases a great deal of heat, so acid must always be added to water, never water to acid. Do not leave water or weak acid standing in an iron pump: drain it fully, and follow your site procedure for any flush.</p>

<p>High-silicon cast iron (STSi15R) is a different material. It resists sulfuric acid across the whole concentration range, but it is expensive, very brittle and hard to machine. It is used in other pump types, not in GBW.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="why-a-pump-is-harder-on-the-film-than-a-pipe--2">Why a Pump Is Harder on the Film Than a Pipe</h2><a class="header-anchor" href="#why-a-pump-is-harder-on-the-film-than-a-pipe--2" title="Why a Pump Is Harder on the Film Than a Pipe" aria-label="Why a Pump Is Harder on the Film Than a Pipe"></a></div>

<p>The iron sulfate film is soft, and fast flow wears it away. Industry guidance for carbon steel piping in concentrated acid limits the flow velocity to about 0.9 m/s. Inside a pump the speeds are far higher: at 2,900 rpm, the tip of a GBW impeller between 100 mm and 250 mm in diameter moves at roughly 15 to 38 m/s.</p>

<p>GBW pumps are designed for this, but they are not suited to very high-velocity duties, and anything that adds turbulence shortens their life:</p>

<ul>
	<li>Gas bubbles and cavitation, which scour the film. Keep a clear margin between NPSH available and NPSH required.</li>
	<li>Running far from the best efficiency point, especially when throttled close to shutoff.</li>
	<li>Solids in the acid, which abrade the film.</li>
</ul>

<p>For the hydraulic side of selection, see our guide on <a href="https://www.shinjopump.com/news/how-to-select-a-centrifugal-pump.html">how to select a centrifugal pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="the-gbw-concentrated-sulfuric-acid-pump--3">The GBW Concentrated Sulfuric Acid Pump</h2><a class="header-anchor" href="#the-gbw-concentrated-sulfuric-acid-pump--3" title="The GBW Concentrated Sulfuric Acid Pump" aria-label="The GBW Concentrated Sulfuric Acid Pump"></a></div>

<div class="sj-gallery">
<figure><a href="https://www.shinjopump.com/gbw-concentrated-sulfuric-acid-centrifugal-pump.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal%20Pumps/gbw-concentrated-sulfuric-acid-centrifugal-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/c5ff2518d7c796a960b893c341967fc2/gbw-concentrated-sulfuric-acid-centrifugal-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/c5ff2518d7c796a960b893c341967fc2/gbw-concentrated-sulfuric-acid-centrifugal-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo GBW concentrated sulfuric acid centrifugal pump on a baseplate with motor" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo GBW concentrated sulfuric acid centrifugal pump on a baseplate with motor' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>GBW, 80&ndash;98% acid</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/ihf-fluorine-plastic-lining-centrifugal-pump-teflon-lined-pump.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal%20Pumps/ihf-fluorine-plastic-lining-centrifugal-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/344d799a710d67601fb0f1c43fad729b/ihf-fluorine-plastic-lining-centrifugal-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Centrifugal Pumps/resize/344d799a710d67601fb0f1c43fad729b/ihf-fluorine-plastic-lining-centrifugal-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo IHF fluoroplastic-lined centrifugal pump for corrosive acid" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo IHF fluoroplastic-lined centrifugal pump for corrosive acid' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>IHF, lined</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/cqb-f-teflon-lining-magnetic-drive-pump-corrosion-resistant-pump.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic%20Drive%20Pumps/cqb-f-teflon-lining-magnetic-drive-pump.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/02a1b4dc23141d77218a7ef6d254010d/cqb-f-teflon-lining-magnetic-drive-pump-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Magnetic Drive Pumps/resize/02a1b4dc23141d77218a7ef6d254010d/cqb-f-teflon-lining-magnetic-drive-pump-400x400.webp 400w" width="400" height="400"  
      alt="Shinjo CQB-F fluoroplastic-lined magnetic drive pump" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo CQB-F fluoroplastic-lined magnetic drive pump' loading='lazy'  sizes="(max-width: 400px) 96vw, 400px"  /></a>

<figcaption>CQB-F, lined, sealless</figcaption>
</figure>

<figure><a href="https://www.shinjopump.com/fluoroplastics-anti-corrosion-submerged-pump-12-28-meters.html"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/products/Vertical%20Submerged%20Pumps/fluoroplastics-anti-corrosion-submerged-pump-12-28-meters.jpg" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/products/Vertical Submerged Pumps/resize/14f212851295774cacdc2d04bfb1d189/fluoroplastics-anti-corrosion-submerged-pump-12-28-meters-320x426.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/products/Vertical Submerged Pumps/resize/14f212851295774cacdc2d04bfb1d189/fluoroplastics-anti-corrosion-submerged-pump-12-28-meters-500x666.webp 500w" width="500" height="666"  
      alt="Shinjo fluoroplastic vertical submerged pump for acid tanks and sumps" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Shinjo fluoroplastic vertical submerged pump for acid tanks and sumps' loading='lazy'  sizes="(max-width: 500px) 96vw, 500px"  /></a>

<figcaption>Submerged, for tanks</figcaption>
</figure>
</div>

<p>The GBW is a horizontal centrifugal pump built on ISW-type hydraulics for concentrated sulfuric acid.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Item</th>
			<th>GBW specification</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Capacity</td>
			<td>4&ndash;550 m&sup3;/h</td>
		</tr>
		<tr>
			<td>Head</td>
			<td>12.5&ndash;50 m</td>
		</tr>
		<tr>
			<td>Size</td>
			<td>DN25&ndash;DN250</td>
		</tr>
		<tr>
			<td>Speed</td>
			<td>2,900 rpm</td>
		</tr>
		<tr>
			<td>Gray cast iron version (HT200/HT250)</td>
			<td>80&ndash;98% acid, 25&ndash;50 &deg;C</td>
		</tr>
		<tr>
			<td>WCB carbon steel version</td>
			<td>80&ndash;98% acid, 25&ndash;60 &deg;C</td>
		</tr>
		<tr>
			<td>Standard seal</td>
			<td>External PTFE bellows single seal, no cooling water needed</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Where the concentration can fall below 80% or the temperature exceeds 60 &deg;C, use a fluoroplastic-lined pump instead, as described in the next section. The full range is in our <a href="https://www.shinjopump.com/chemical-process-pumps.html">chemical process pumps</a> category.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="lined-pumps-for-98-acid-what-still-applies--4">Lined Pumps for 98% Acid: What Still Applies</h2><a class="header-anchor" href="#lined-pumps-for-98-acid-what-still-applies--4" title="Lined Pumps for 98% Acid: What Still Applies" aria-label="Lined Pumps for 98% Acid: What Still Applies"></a></div>

<p>The IHF and CQB-F are lined with FEP (F46), a fluoroplastic that resists 98% sulfuric acid without being oxidized by it. Chemical resistance is not the whole story, though. Temperature, water and the extra weight of the acid still decide how long a lined pump lasts.</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>&nbsp;</th>
			<th>IHF lined centrifugal pump</th>
			<th>CQB-F lined magnetic drive pump</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Lining</td>
			<td>FEP (F46)</td>
			<td>FEP (F46)</td>
		</tr>
		<tr>
			<td>Flow and head</td>
			<td>3&ndash;130 m&sup3;/h, 5&ndash;87 m</td>
			<td>1.8&ndash;100 m&sup3;/h, 8&ndash;32 m</td>
		</tr>
		<tr>
			<td>Published liquid temperature</td>
			<td>Up to 80 &deg;C</td>
			<td>Up to 80 &deg;C</td>
		</tr>
		<tr>
			<td>Shaft sealing</td>
			<td>Mechanical seal: SiC/SiC faces, PTFE bellows, Hastelloy C-276 springs</td>
			<td>No shaft seal</td>
		</tr>
		<tr>
			<td>Best for</td>
			<td>Steady duty and larger flows</td>
			<td>Zero-leakage duty at small and medium flows</td>
		</tr>
		<tr>
			<td>Main risk</td>
			<td>Leakage at the mechanical seal</td>
			<td>Dry running, cavitation and gas, which destroy the internal bearings</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>Three conditions apply to both pumps:</p>

<ul>
	<li><strong>Temperature protects the lining bond, not just the plastic.</strong> FEP and the steel casing expand at very different rates, so high temperature and rapid heating or cooling can blister the lining or separate it from the steel. Do not run at the top of the range, and avoid thermal shock.</li>
	<li><strong>Keep water out.</strong> Water or weak acid entering the pump dilutes the acid locally and releases heat, and that local hot spot can blister the lining.</li>
	<li><strong>Size the motor for SG 1.84.</strong> Published motor ratings are for water, as the next section explains.</li>
</ul>

<p>The CQB-F has two further requirements. Its internal bearings are lubricated and cooled only by the pumped acid, so a few minutes of dry running, cavitation or entrained gas can melt the bearings, overheat the containment shell and demagnetize the magnets. Concentrated acid is heavy and viscous, which makes cavitation more likely, so check NPSH with a clear margin and fit dry-running protection, such as motor power monitoring or a flow switch. The magnetic coupling must also be rated for the acid: a coupling sized for water can slip and lose its magnetism at SG 1.84, so both the coupling torque and the motor power have to be increased. Keep the liquid at or below 80 &deg;C, because the risk of demagnetization rises with temperature. For more on sealless pumps, see <a href="https://www.shinjopump.com/news/the-selection-principle-and-precautions-for-magnetic-drive-pumps.html">how to select a magnetic drive pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="size-the-motor-for-an-acid-1-84-times-heavier-than-water--5">Size the Motor for an Acid 1.84 Times Heavier Than Water</h2><a class="header-anchor" href="#size-the-motor-for-an-acid-1-84-times-heavier-than-water--5" title="Size the Motor for an Acid 1.84 Times Heavier Than Water" aria-label="Size the Motor for an Acid 1.84 Times Heavier Than Water"></a></div>

<p>Density does not change the head a centrifugal pump develops, but it raises the discharge pressure and the power in direct proportion. Sulfuric acid at 93% to 98% has a density of about 1.83 to 1.84 kg/L, and acid at 78% to 80% about 1.70 to 1.73. Size the motor for the strongest acid the pump will see. For how head and pressure relate, see <a href="https://www.shinjopump.com/news/what-is-pump-head-and-total-head-total-dynamic-head.html">what pump head means</a>.</p>

<p>Catalogue tables, including the GBW table, are rated on water (SG 1.0) unless they say otherwise. Take the GBW65-160 as an example: 25 m&sup3;/h at 32 m, listed with a 5.5 kW motor. Assuming a pump efficiency of 60%:</p>

<p class="sj-formula">Shaft power = &rho; &times; g &times; Q &times; H &divide; &eta;<br />
Water: 1,000 &times; 9.81 &times; (25 &divide; 3,600) &times; 32 &divide; 0.60 &asymp; 3.6 kW<br />
98% acid: 1,840 &times; 9.81 &times; (25 &divide; 3,600) &times; 32 &divide; 0.60 &asymp; 6.7 kW</p>

<p>The 5.5 kW motor is fine for water and overloaded on 98% acid. With a service margin added, the next standard size is 7.5 kW, or 11 kW if your standard applies a 15% margin. Concentrated acid is also about 25 times as viscous as water at 20 &deg;C, which lowers efficiency a little further. Before ordering any concentrated sulfuric acid pump, ask the supplier to confirm in writing that the motor has been sized for SG 1.84.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="the-mechanical-seal-what-to-write-into-the-order--6">The Mechanical Seal: What to Write into the Order</h2><a class="header-anchor" href="#the-mechanical-seal-what-to-write-into-the-order--6" title="The Mechanical Seal: What to Write into the Order" aria-label="The Mechanical Seal: What to Write into the Order"></a></div>

<p>The GBW&#39;s standard seal is a WB2-type external PTFE bellows single seal. It sits outside the acid and needs no cooling water. Seal configurations vary between manufacturers, so specify these items in the contract:</p>

<div class="sj-table">
<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Seal part</th>
			<th>Specify</th>
			<th>Avoid</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Seal faces</td>
			<td>Silicon carbide against silicon carbide (SiC/SiC)</td>
			<td>Ceramic against graphite: concentrated acid slowly oxidizes graphite</td>
		</tr>
		<tr>
			<td>Alternative faces</td>
			<td>99% alumina ceramic against SiC: cheaper, less resistant to thermal shock</td>
			<td>&mdash;</td>
		</tr>
		<tr>
			<td>Secondary seals</td>
			<td>PTFE</td>
			<td>&mdash;</td>
		</tr>
		<tr>
			<td>Springs and small metal parts</td>
			<td>Hastelloy C-276</td>
			<td>304 stainless steel: acid mist corrodes it and the seal sticks</td>
		</tr>
	</tbody>
</table></div>
</div>

<p>The same seal configuration applies to the IHF lined pump.</p>

<div class="sj-warn">
<div class="sj-warn-title">Red lines for iron sulfuric acid pumps</div>

<ul>
	<li><b>Never below 80% concentration.</b> The protective film dissolves and corrosion accelerates. Keep cast iron and carbon steel out of the 65&ndash;80% range entirely.</li>
	<li><b>No oleum in cast iron.</b> Free sulfur trioxide reacts with the silicon in cast iron and makes it brittle and cracked. Carbon steel tolerates oleum above 102% only for short periods.</li>
	<li><b>No high velocity or gas scouring.</b> Fast flow and bubbles wear the film away.</li>
	<li><b>Stay within the temperature limit:</b> 50 &deg;C for gray cast iron, 60 &deg;C for WCB carbon steel.</li>
	<li><b>No water left in the pump.</b> Diluted acid attacks the iron and releases heat.</li>
</ul>
</div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="what-to-send-with-your-enquiry--7">What to Send with Your Enquiry</h2><a class="header-anchor" href="#what-to-send-with-your-enquiry--7" title="What to Send with Your Enquiry" aria-label="What to Send with Your Enquiry"></a></div>

<ul>
	<li>Acid concentration: minimum, normal and maximum, including startup, cleaning and upset conditions.</li>
	<li>Liquid temperature: normal and maximum.</li>
	<li>Flow rate and total head, with the suction conditions and NPSH available.</li>
	<li>Impurities and solids, and whether water can enter the system.</li>
	<li>Operating pattern: continuous, batch, or intermittent transfer.</li>
	<li>Installation: horizontal pump with flooded suction, or transfer from a tank or sump.</li>
	<li>Motor standard, voltage and frequency, and a request to confirm the motor for SG 1.84.</li>
	<li>Seal configuration: SiC/SiC faces, PTFE secondary seals and Hastelloy C-276 springs.</li>
	<li>For a magnetic drive pump: a magnetic coupling rated for SG 1.84, and dry-running protection.</li>
</ul>

<p class="sj-cta">Need a pump for sulfuric acid? Send these details to SHINJO and we will <a href="https://www.shinjopump.com/contact.html">recommend a model and material</a> for your concentration and temperature.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 class="scrollspy-head" id="faq--8">FAQ</h2><a class="header-anchor" href="#faq--8" title="FAQ" aria-label="FAQ"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="what-is-the-best-material-for-a-98-sulfuric-acid-pump--9">What is the best material for a 98% sulfuric acid pump?</h3><a class="header-anchor" href="#what-is-the-best-material-for-a-98-sulfuric-acid-pump--9" title="What is the best material for a 98% sulfuric acid pump?" aria-label="What is the best material for a 98% sulfuric acid pump?"></a></div>

<p>For 80% to 98% acid, gray cast iron is suitable up to 50 &deg;C and WCB carbon steel up to 60 &deg;C, because the acid forms a protective iron sulfate film on them. Above those temperatures, or where the concentration can fall below 80%, a fluoroplastic-lined pump is the safer choice.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-cast-iron-pump-handle-70-sulfuric-acid--10">Can a cast iron pump handle 70% sulfuric acid?</h3><a class="header-anchor" href="#can-a-cast-iron-pump-handle-70-sulfuric-acid--10" title="Can a cast iron pump handle 70% sulfuric acid?" aria-label="Can a cast iron pump handle 70% sulfuric acid?"></a></div>

<p>No. Below 80% the protective film dissolves, and the range from 65% to 80% is the most aggressive for iron. Use a fluoroplastic-lined pump for that range.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-stainless-steel-pump-concentrated-sulfuric-acid--11">Can stainless steel pump concentrated sulfuric acid?</h3><a class="header-anchor" href="#can-stainless-steel-pump-concentrated-sulfuric-acid--11" title="Can stainless steel pump concentrated sulfuric acid?" aria-label="Can stainless steel pump concentrated sulfuric acid?"></a></div>

<p>Only within narrow concentration and temperature windows. Common grades such as 316 corrode badly in the middle of the concentration range, so stainless steel is not a default choice for sulfuric acid pumps.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-ptfe-or-fep-lined-pump-handle-98-sulfuric-acid--12">Can a PTFE- or FEP-lined pump handle 98% sulfuric acid?</h3><a class="header-anchor" href="#can-a-ptfe-or-fep-lined-pump-handle-98-sulfuric-acid--12" title="Can a PTFE- or FEP-lined pump handle 98% sulfuric acid?" aria-label="Can a PTFE- or FEP-lined pump handle 98% sulfuric acid?"></a></div>

<p>Yes, chemically. FEP and PTFE linings resist 98% sulfuric acid. The limits are temperature, published as 80 &deg;C for the IHF and CQB-F to protect the bond between lining and steel; keeping water out of the pump; and sizing the motor for SG 1.84.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="can-a-magnetic-drive-pump-run-dry-on-sulfuric-acid--13">Can a magnetic drive pump run dry on sulfuric acid?</h3><a class="header-anchor" href="#can-a-magnetic-drive-pump-run-dry-on-sulfuric-acid--13" title="Can a magnetic drive pump run dry on sulfuric acid?" aria-label="Can a magnetic drive pump run dry on sulfuric acid?"></a></div>

<p>No. Its internal bearings are lubricated and cooled by the acid itself, so dry running, cavitation or gas bubbles can destroy the bearings and demagnetize the coupling within minutes. Fit dry-running protection and make sure the coupling is rated for SG 1.84.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 class="scrollspy-head" id="does-the-acid-39-s-density-change-the-pump-head--14">Does the acid&#39;s density change the pump head?</h3><a class="header-anchor" href="#does-the-acid-39-s-density-change-the-pump-head--14" title="Does the acid&#39;s density change the pump head?" aria-label="Does the acid&#39;s density change the pump head?"></a></div>

<p>No. The head stays the same, but the discharge pressure and the power rise in proportion to density, so 98% acid needs about 1.84 times the shaft power of water.</p>
</div>
</div></div>
    ]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>Pneumatic Diaphragm Pump (AODD Pump): Sizing and Air Use</title>
      <description><![CDATA[How to size a pneumatic diaphragm pump (AODD pump): the 1:1 pressure rule, reading the curve for SCFM, compressor size, air cost, elastomers and ATEX.]]></description>
      <pubDate>Wed, 23 Sep 2026 03:43:22 +0000</pubDate>
      <link>https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html?utm_source=rss</link>
      <guid>https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html?utm_source=rss</guid>
      <content:encoded><![CDATA[<div class="toc-wrapper"><div class="toc-anchor ">
  <div class="toc-inner-wrapper">
  <div>On this page</div>
  <div id="cursor1792925401"></div>
  <div class="menu-wrapper1792925401"></div></div></div>
  <div class="toc-content"><div class="shinjopump-pillar">
<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="abstract--0" class="scrollspy-head">Abstract</h2><a class="header-anchor" href="#abstract--0" title="Abstract" aria-label="Abstract"></a></div>

<p>A pneumatic diaphragm pump, also called an AODD pump (air-operated double diaphragm), is specified from its air side. Discharge pressure cannot exceed the air pressure driving the pump: standard 1:1 ratio AODD pumps are rated to 125 psi (8.6 bar) (Versamatic, n.d.-a). Flow follows from that same rule, and the pump&#39;s air consumption at the duty point, read off the manufacturer&#39;s performance curve in SCFM, sets three things at once: the delivered flow, the compressor horsepower the plant must provide, and the hourly electricity cost of running the pump. Suction lift, viscosity, solids and elastomer choice only shift the numbers on that same curve.</p>

<figure class="xr-figure wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP.webp" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-320x180.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-640x360.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-800x450.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-1024x576.webp 1024w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-1280x720.webp 1280w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-1600x900.webp 1600w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-1920x1080.webp 1920w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-2048x1152.webp 2048w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-2560x1440.webp 2560w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-3200x1800.webp 3200w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/5a4c2251898d81a941094381f3661761/pneumatic-diaphragm-pump-aodd-plant-installation-cover_V8CmWP-3840x2160.webp 3840w" width="3840" height="2160"  
      alt="Metal air-operated double diaphragm pump on a chemical plant floor with compressed-air line, filter-regulator, pressure gauge and process hoses" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Metal air-operated double diaphragm pump on a chemical plant floor with compressed-air line, filter-regulator, pressure gauge and process hoses' loading='lazy'  sizes="(max-width: 3840px) 96vw, 3840px"  />
<figcaption>An air-operated double diaphragm pump on a plant floor, with its compressed-air line, filter-regulator and pressure gauge on the air side and process hoses on the liquid side.</figcaption>
</figure>

<p>This guide is for procurement and project engineers who arrive with a duty and must specify or approve a pneumatic diaphragm pump against it. It covers the 1:1 rule, reading the performance curve, converting SCFM to compressor size and hourly cost, derating for suction lift, viscosity and solids, matching housings and elastomers to temperature and chemistry, what ATEX asks of an air-driven pump, when an electric diaphragm pump is the better buy, and the AODD pump specification a vendor needs in an RFQ.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="key-takeaways--1" class="scrollspy-head">Key Takeaways</h2><a class="header-anchor" href="#key-takeaways--1" title="Key Takeaways" aria-label="Key Takeaways"></a></div>

<ul>
	<li><strong>The 1:1 rule.</strong> An AODD pump&#39;s discharge pressure cannot exceed its air inlet, rated to 125 psi (8.6 bar).</li>
	<li><strong>Read the curve.</strong> At your flow and discharge pressure, the air-consumption lines give the SCFM the pump will draw.</li>
	<li><strong>Size the compressor.</strong> Around 1 hp per 4.5 SCFM, the PSG/Blackmer rule of thumb.</li>
	<li><strong>Air is the running cost.</strong> At an illustrative $0.15/kWh, 118 SCFM of compressed air costs about $2.94 an hour to generate.</li>
	<li><strong>Elastomer limits vary by manufacturer.</strong> PTFE trades flex life for chemical resistance, so check the chosen pump&#39;s own documentation.</li>
	<li><strong>Air drive is not ATEX.</strong> Ask the supplier for the Ex marking and ground the pump, piping and containers.</li>
	<li><strong>Continuous high-duty transfer favors electric.</strong> An electric diaphragm pump can use far less energy than compressed air.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="table-of-contents--2" class="scrollspy-head">Table of Contents</h2><a class="header-anchor" href="#table-of-contents--2" title="Table of Contents" aria-label="Table of Contents"></a></div>

<ul>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#abstract">Abstract</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#key-takeaways">Key Takeaways</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#what-a-pneumatic-diaphragm-pump-is-in-one-air-cycle">What a pneumatic diaphragm pump is, in one air cycle</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#glossary">Glossary</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#the-11-rule-air-pressure-caps-discharge-pressure">The 1:1 rule: air pressure caps discharge pressure</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#how-to-read-an-aodd-pump-performance-curve">How to read an AODD pump performance curve</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#air-consumption-compressor-size-and-running-cost">Air consumption, compressor size and running cost</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#suction-lift-viscosity-and-solids-change-the-curve">Suction lift, viscosity and solids change the curve</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#wetted-materials-and-elastomers-temperature-chemistry-flex-life">Wetted materials and elastomers: temperature, chemistry, flex life</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#hazardous-areas-air-driven-is-not-the-same-as-atex-rated">Hazardous areas: air-driven is not the same as ATEX-rated</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#when-an-aodd-pump-is-the-wrong-choice">When an AODD pump is the wrong choice</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#the-aodd-specification-to-send-with-an-rfq">The AODD specification to send with an RFQ</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#frequently-asked-questions">Frequently Asked Questions</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#conclusion">Conclusion</a></li>
	<li><a href="https://www.shinjopump.com/news/pneumatic-diaphragm-pump-aodd-pump.html#references">References</a></li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="what-a-pneumatic-diaphragm-pump-is-in-one-air-cycle--3" class="scrollspy-head">What a pneumatic diaphragm pump is, in one air cycle</h2><a class="header-anchor" href="#what-a-pneumatic-diaphragm-pump-is-in-one-air-cycle--3" title="What a pneumatic diaphragm pump is, in one air cycle" aria-label="What a pneumatic diaphragm pump is, in one air cycle"></a></div>

<p>A pneumatic diaphragm pump, also called an AODD pump (air-operated double diaphragm pump), is a positive-displacement pump in which compressed air, switched by an internal air valve, drives two diaphragms joined by a shaft; while one chamber discharges the other fills, and four check valves keep the liquid moving one way. The liquid never passes through the air valve. Shinjo&#39;s QBY catalog names the same machine both an &quot;Air Operated Double Diaphragm Pump (AODD)&quot; and a &quot;Pneumatic Diaphragm Pump&quot;; the two terms describe one design.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="the-air-side-and-the-liquid-side--4" class="scrollspy-head">The air side and the liquid side</h3><a class="header-anchor" href="#the-air-side-and-the-liquid-side--4" title="The air side and the liquid side" aria-label="The air side and the liquid side"></a></div>

<figure class="xr-figure wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/aodd-pump-air-side-filter-regulator-gauge-muffler_FEOZ96.png" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/f7d49cf9e1f8f641d391fbccaf874779/aodd-pump-air-side-filter-regulator-gauge-muffler_FEOZ96-320x228.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/f7d49cf9e1f8f641d391fbccaf874779/aodd-pump-air-side-filter-regulator-gauge-muffler_FEOZ96-640x457.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/f7d49cf9e1f8f641d391fbccaf874779/aodd-pump-air-side-filter-regulator-gauge-muffler_FEOZ96-800x571.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/f7d49cf9e1f8f641d391fbccaf874779/aodd-pump-air-side-filter-regulator-gauge-muffler_FEOZ96-894x638.webp 894w" width="894" height="638"  
      alt="Air side of an AODD pump showing the supply line, filter-regulator with pressure gauge, and exhaust muffler on the pump's center section" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Air side of an AODD pump showing the supply line, filter-regulator with pressure gauge, and exhaust muffler on the pump's center section' loading='lazy'  sizes="(max-width: 894px) 96vw, 894px"  />
<figcaption>The air side of an installed AODD pump: supply line, filter-regulator with gauge, and the exhaust muffler on the center section.</figcaption>
</figure>

<p>The air side receives compressed air through a filter-regulator and gauge, distributes it alternately between the two chambers, and vents each spent charge through an exhaust muffler on the center section. The liquid side stays sealed from the air side by the diaphragms; four check valves, two suction and two discharge, sit in the manifolds. For a component-by-component tour, see Shinjo&#39;s <a href="https://www.shinjopump.com/news/diaphragm-pump.html" rel="noopener" target="_blank">full parts walkthrough of the AODD pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="why-the-flow-pulses-and-what-sets-the-stroke-rate--5" class="scrollspy-head">Why the flow pulses, and what sets the stroke rate</h3><a class="header-anchor" href="#why-the-flow-pulses-and-what-sets-the-stroke-rate--5" title="Why the flow pulses, and what sets the stroke rate" aria-label="Why the flow pulses, and what sets the stroke rate"></a></div>

<p>A pneumatic diaphragm pump (AODD pump) moves liquid by shifting two diaphragms joined by a shaft with alternating compressed air; flow equals strokes per minute times displacement per stroke. Versamatic states a 2-inch bolted metal pump displaces 0.60 gal (2.27 L) per stroke, and stroke rate falls as back pressure rises (Versamatic, n.d.-a).</p>

<p>A stroke is one shift of the diaphragm assembly; a cycle is two strokes. More inlet air raises the stroke rate; more back pressure lowers it. Because discharge alternates between chambers, the output pulses at the stroke frequency, so downstream equipment sensitive to pressure ripple needs a dampener (Yamada Pump, n.d.-b).</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="glossary--6" class="scrollspy-head">Glossary</h2><a class="header-anchor" href="#glossary--6" title="Glossary" aria-label="Glossary"></a></div>

<ul>
	<li><strong>Stroke</strong>: one shift of the diaphragm assembly from one side to the other.</li>
	<li><strong>Cycle</strong>: two strokes, one full oscillation of the pair.</li>
	<li><strong>Displacement per stroke</strong>: the fixed liquid volume moved per stroke.</li>
	<li><strong>SCFM</strong>: standard cubic feet per minute; the pump&#39;s compressed-air demand at stated inlet conditions.</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="the-1-1-rule-air-pressure-caps-discharge-pressure--7" class="scrollspy-head">The 1:1 rule: air pressure caps discharge pressure</h2><a class="header-anchor" href="#the-1-1-rule-air-pressure-caps-discharge-pressure--7" title="The 1:1 rule: air pressure caps discharge pressure" aria-label="The 1:1 rule: air pressure caps discharge pressure"></a></div>

<p>Standard 1:1 ratio AODD pumps can produce pressures up to 125 psi (8.6 bar), which in practice caps the discharge a pneumatic diaphragm pump can deliver (Versamatic, n.d.-a). The inlet air pressure is the ceiling for the outlet discharge pressure. At any useful flow the discharge sits below the inlet, because pressure difference is what pushes the liquid through the check valves.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-1-1-means-on-a-datasheet--8" class="scrollspy-head">What 1:1 means on a datasheet</h3><a class="header-anchor" href="#what-1-1-means-on-a-datasheet--8" title="What 1:1 means on a datasheet" aria-label="What 1:1 means on a datasheet"></a></div>

<p>&quot;1:1&quot; describes the ratio of maximum liquid discharge pressure to air inlet pressure on the datasheet. Global Pumps&#39; worked example makes the practical picture clear: 7 bar of inlet air delivers 200 L/min at 4 bar of discharge pressure (Global Pumps, n.d.). Where the plant compressed-air header could exceed 8.6 bar, a filter-regulator belongs upstream of the pump so the inlet never crosses the standard 125 psi ceiling. Shinjo lists its QBY3 series with an outlet pressure of 0.7 MPa (7 kgf/cm&sup2;) against an air supply of 0.3 to 0.7 MPa; its older QBY catalog lists 6 kgf/cm&sup2; discharge pressure against a 7 kgf/cm&sup2; maximum air supply. Both readings are consistent with the 1:1 rule.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="convert-head-to-pressure-before-you-compare--9" class="scrollspy-head">Convert head to pressure before you compare</h3><a class="header-anchor" href="#convert-head-to-pressure-before-you-compare--9" title="Convert head to pressure before you compare" aria-label="Convert head to pressure before you compare"></a></div>

<p>A duty stated in meters of head must be converted to pressure before comparing it with air supply. For water at specific gravity 1.0, 10.2 m of head is about 1 bar; divide by the liquid&#39;s specific gravity for other fluids. Shinjo lists a maximum head of 70 m for its QBY3 series; that head must be expressed as bar before it is compared with the air supply. Redo the conversion for a liquid heavier or lighter than water.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="when-a-2-1-pump-is-the-answer--10" class="scrollspy-head">When a 2:1 pump is the answer</h3><a class="header-anchor" href="#when-a-2-1-pump-is-the-answer--10" title="When a 2:1 pump is the answer" aria-label="When a 2:1 pump is the answer"></a></div>

<p>Some AODD designs use a 2:1 ratio that roughly doubles the discharge pressure by trading flow and air. Consider one when the duty needs more than the standard 125 psi ceiling and the compressor has headroom; expect lower flow and higher air use per liter delivered. Ask the manufacturer for the model&#39;s own curves and air-consumption lines before comparing a 2:1 unit with a standard pneumatic diaphragm pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="by-the-numbers--11" class="scrollspy-head">By the Numbers</h3><a class="header-anchor" href="#by-the-numbers--11" title="By the Numbers" aria-label="By the Numbers"></a></div>

<ul>
	<li><strong>125 psi</strong> the standard 1:1 AODD pump air-inlet ceiling, per Versamatic (Versamatic, n.d.-a)</li>
	<li><strong>8.6 bar</strong> metric equivalent of the same 1:1 pressure limit (Versamatic, n.d.-a)</li>
	<li><strong>10.2 m</strong> water head equal to about 1 bar at specific gravity 1.0</li>
	<li><strong>7 bar in</strong> what Global Pumps needs for 4 bar out at 200 L/min (Global Pumps, n.d.)</li>
</ul>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="how-to-read-an-aodd-pump-performance-curve--12" class="scrollspy-head">How to read an AODD pump performance curve</h2><a class="header-anchor" href="#how-to-read-an-aodd-pump-performance-curve--12" title="How to read an AODD pump performance curve" aria-label="How to read an AODD pump performance curve"></a></div>

<p>To size a pneumatic diaphragm pump, plot the duty point where discharge pressure meets required flow on the manufacturer&#39;s curve, then read air-inlet pressure and SCFM at that intersection. Global Pumps illustrates it: 200 L/min at 4 bar discharge needs 7 bar inlet air at 60 SCFM (Global Pumps, n.d.), about 1.7 m&sup3;/min.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="the-four-sets-of-lines-on-the-curve--13" class="scrollspy-head">The four sets of lines on the curve</h3><a class="header-anchor" href="#the-four-sets-of-lines-on-the-curve--13" title="The four sets of lines on the curve" aria-label="The four sets of lines on the curve"></a></div>

<p>One chart carries four families. The horizontal axis reads flow in L/min or US gpm. The vertical axis reads discharge pressure or head. Rising curves from left to right label air inlet pressure in bar or psi. A second set sloping the opposite way labels air consumption in SCFM or m&sup3;/min. A valid reading finds where all four agree, so confirm the plant compressor supplies that pressure and volume before the model is chosen.</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Curve element</th>
			<th>What it shows</th>
			<th>How to use it</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Flow axis</td>
			<td>Discharge flow, L/min or US gpm</td>
			<td>Enter your duty flow</td>
		</tr>
		<tr>
			<td>Pressure axis</td>
			<td>Discharge pressure or head</td>
			<td>Enter your duty pressure</td>
		</tr>
		<tr>
			<td>Air-inlet curves</td>
			<td>Air pressure at the pump inlet, bar or psi</td>
			<td>Read the curve through the intersection</td>
		</tr>
		<tr>
			<td>Air-consumption curves</td>
			<td>Air use, SCFM or m&sup3;/min</td>
			<td>Read the second curve at the same point</td>
		</tr>
	</tbody>
</table></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="a-worked-reading-200-l-min-at-4-bar--14" class="scrollspy-head">A worked reading: 200 L/min at 4 bar</h3><a class="header-anchor" href="#a-worked-reading-200-l-min-at-4-bar--14" title="A worked reading: 200 L/min at 4 bar" aria-label="A worked reading: 200 L/min at 4 bar"></a></div>

<p>Follow Global Pumps&#39; intersection method. Draw a horizontal line from 4 bar and a vertical line from 200 L/min. Their meeting point sits on the 7 bar air-inlet curve and the 60 SCFM air-consumption curve. That is 7 bar inlet air at 60 SCFM, or about 1.7 m&sup3;/min (1 SCFM &asymp; 0.0283 m&sup3;/min). Manufacturer conventions differ. PSG&#39;s Blackmer example places a similar duty between the 60 and 80 SCFM lines, about 72 SCFM (PSG Blackmer, 2022). Never blend three curves; use only the curve for the model quoted.</p>

<p>Steps to read any AODD curve:</p>

<ol>
	<li><strong>Confirm the fluid.</strong> Published curves are drawn for water at specific gravity 1.0 (Van Ormer, n.d.).</li>
	<li><strong>Locate duty flow</strong> on the horizontal axis.</li>
	<li><strong>Locate duty pressure</strong> on the vertical axis.</li>
	<li><strong>Mark the intersection</strong> of the two lines.</li>
	<li><strong>Read the air-inlet curve</strong> passing through that point in bar or psi.</li>
	<li><strong>Read the air-consumption curve</strong> at the same point in SCFM or m&sup3;/min.</li>
</ol>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="where-on-the-curve-to-run-the-pump--15" class="scrollspy-head">Where on the curve to run the pump</h3><a class="header-anchor" href="#where-on-the-curve-to-run-the-pump--15" title="Where on the curve to run the pump" aria-label="Where on the curve to run the pump"></a></div>

<p>The outer envelope of the curve is the pump running at maximum air pressure and maximum flow. Do not size a duty point on that line. Leave margin for conditions the water test cannot show: higher viscosity, suction lift, diaphragm and check-ball wear, and pressure spikes on the discharge. Run inside the envelope, not on it. If the supplier publishes only a partial curve or none at all (Shinjo&#39;s QBY3 landing page shows no air-consumption lines), ask for the full curve with both air families plotted before the pump is selected.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="air-consumption-compressor-size-and-running-cost--16" class="scrollspy-head">Air consumption, compressor size and running cost</h2><a class="header-anchor" href="#air-consumption-compressor-size-and-running-cost--16" title="Air consumption, compressor size and running cost" aria-label="Air consumption, compressor size and running cost"></a></div>

<p>A generic 2-inch pneumatic diaphragm pump (AODD pump) uses 90 to 120 scfm at an average 95 psig inlet, per Compressed Air Best Practices (Van Ormer, n.d.). That is the number to start from when a duty is not yet on a curve, and it is why air is treated as its own line on the specification: the pump has no motor, so every drop of duty is paid for by the compressor.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="from-scfm-to-compressor-horsepower--17" class="scrollspy-head">From SCFM to compressor horsepower</h3><a class="header-anchor" href="#from-scfm-to-compressor-horsepower--17" title="From SCFM to compressor horsepower" aria-label="From SCFM to compressor horsepower"></a></div>

<p>PSG/Blackmer&#39;s rule of thumb sizes the compressor at about 1 hp per 4.5 SCFM (PSG Blackmer, 2022). In its own worked example, 72 SCFM divided by 4.5 gives 16 hp; because industrial compressors are sold in 5 hp increments, round up to a 20 hp unit. Electric horsepower converts to kilowatts at kW = hp x 0.746, which is the input a utility bill sees.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-the-compressed-air-costs-per-hour--18" class="scrollspy-head">What the compressed air costs per hour</h3><a class="header-anchor" href="#what-the-compressed-air-costs-per-hour--18" title="What the compressed air costs per hour" aria-label="What the compressed air costs per hour"></a></div>

<p>Take All-Flo&#39;s published duty point of 118 SCFM (from a 2-inch pump at 80 psi inlet, 20 psi discharge) and apply the PSG/Blackmer chain: 118 SCFM divides by 4.5 to 26.2 hp; 26.2 hp times 0.746 gives 19.6 kW; at an illustrative $0.15/kWh, that is $2.94 per hour (PSG Blackmer, 2022; All-Flo Pump, n.d.). Electricity prices move that answer sharply. EIA&#39;s June 2026 industrial data shows Louisiana at 6.69 cents/kWh and California at 20.74 cents/kWh (U.S. Energy Information Administration, 2026), so the same 19.6 kW draw costs about $1.31 an hour in Louisiana and about $4.07 an hour in California. At $0.15/kWh, hourly cost scales linearly across the band: 20 SCFM $0.50/h; 40 SCFM $0.99/h; 60 SCFM $1.49/h; 80 SCFM $1.99/h; 100 SCFM $2.49/h; 120 SCFM $2.98/h.</p>

<figure class="xr-figure wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR.png" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/9b36f2ef3a08012f4c758c6b0a987ecd/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/9b36f2ef3a08012f4c758c6b0a987ecd/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR-640x640.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/9b36f2ef3a08012f4c758c6b0a987ecd/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR-800x800.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/9b36f2ef3a08012f4c758c6b0a987ecd/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR-1024x1024.webp 1024w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/9b36f2ef3a08012f4c758c6b0a987ecd/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR-1280x1280.webp 1280w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/9b36f2ef3a08012f4c758c6b0a987ecd/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR-1600x1600.webp 1600w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/9b36f2ef3a08012f4c758c6b0a987ecd/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR-1920x1920.webp 1920w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/9b36f2ef3a08012f4c758c6b0a987ecd/aodd-pump-air-electricity-cost-scfm-vs-usd-per-hour_FWkLQR-2048x2048.webp 2048w" width="2048" height="2048"  
      alt="Bar chart of hourly electricity cost for compressed air at $0.15 per kWh, from 20 SCFM ($0.50 per hour) to 120 SCFM ($2.98 per hour)" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Bar chart of hourly electricity cost for compressed air at $0.15 per kWh, from 20 SCFM ($0.50 per hour) to 120 SCFM ($2.98 per hour)' loading='lazy'  sizes="(max-width: 2048px) 96vw, 2048px"  />
<figcaption>Hourly electricity cost of the compressed air an AODD pump draws, at $0.15 per kWh, from 20 to 120 SCFM.</figcaption>
</figure>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="cutting-air-use-without-losing-the-duty--19" class="scrollspy-head">Cutting air use without losing the duty</h3><a class="header-anchor" href="#cutting-air-use-without-losing-the-duty--19" title="Cutting air use without losing the duty" aria-label="Cutting air use without losing the duty"></a></div>

<p>Compressed Air Best Practices puts a 2-inch pump running continuously at an average 80 scfm at about $8,000 a year without batch control and about $800 a year with it, at $0.06/kWh over 8,000 hours a year (Van Ormer, n.d.). Two levers do most of that work. First, stop the pump when the process is not calling for product. Second, run at the lowest inlet air pressure that still meets the duty on the curve, since as viscosity and head rise, strokes per minute and air use fall at the same inlet pressure. Shinjo&#39;s QBY catalog lists maximum air consumption from 0.3 m&sup3;/min (QBY-10 and QBY-15) to 1.5 m&sup3;/min (QBY-80) and 1.4 m&sup3;/min for QBY-100, about 11 to 53 SCFM; the QBY3 landing page publishes no air-consumption figure, so ask for it in the RFQ.</p>

<blockquote>
<p><strong>Air at the pump:</strong> a compressor&#39;s nameplate rating is shared by every user on the header. Regulator, filter, and hose losses drop the pressure the pump actually sees. Meet the curve&#39;s inlet-pressure requirement at the pump inlet, not at the plant main.</p>
</blockquote>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="by-the-numbers--20" class="scrollspy-head">By the Numbers</h3><a class="header-anchor" href="#by-the-numbers--20" title="By the Numbers" aria-label="By the Numbers"></a></div>

<ul>
	<li><strong>90 to 120 scfm</strong> generic 2-inch AODD at 95 psig inlet</li>
	<li><strong>1 hp/4.5 SCFM</strong> compressor sizing rule of thumb</li>
	<li><strong>$2.94/h</strong> 118 SCFM at $0.15/kWh</li>
	<li><strong>$8k vs $800/yr</strong> uncontrolled vs batch-controlled</li>
</ul>

<p>Air is the running cost of a pneumatic diaphragm pump. Applying PSG/Blackmer&#39;s rule to All-Flo&#39;s 118 SCFM duty point gives 19.6 kW; at an illustrative $0.15/kWh, that is $2.94 per hour. Compressed Air Best Practices puts a similar 80 scfm duty at about $8,000 a year uncontrolled and about $800 a year with batch control, at $0.06/kWh over 8,000 hours.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="your-next-step--21" class="scrollspy-head">Your next step</h3><a class="header-anchor" href="#your-next-step--21" title="Your next step" aria-label="Your next step"></a></div>

<p>Once the duty and the available air supply are fixed, the remaining decision is which diaphragm pump family suits the process: air-operated or motor-driven. <a href="https://www.shinjopump.com/diaphragm-pumps.html" rel="noopener" target="_blank">See the diaphragm pump range</a> and send that duty point with your inquiry.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="suction-lift-viscosity-and-solids-change-the-curve--22" class="scrollspy-head">Suction lift, viscosity and solids change the curve</h2><a class="header-anchor" href="#suction-lift-viscosity-and-solids-change-the-curve--22" title="Suction lift, viscosity and solids change the curve" aria-label="Suction lift, viscosity and solids change the curve"></a></div>

<p>A pneumatic diaphragm pump&#39;s performance curve is read for cool water lifted a short distance under a flooded suction. Change the fluid, the geometry or the temperature and the numbers move. Three variables account for most of the shift a buyer will actually see: suction lift, viscosity, and the solids the pump has to swallow.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="dry-lift-is-not-wet-lift--23" class="scrollspy-head">Dry lift is not wet lift</h3><a class="header-anchor" href="#dry-lift-is-not-wet-lift--23" title="Dry lift is not wet lift" aria-label="Dry lift is not wet lift"></a></div>

<p>AODD pumps are self-priming: the air valve alternates strokes even when the chambers are empty, so the diaphragms evacuate air from the suction line and pull liquid up. Dry suction lift on an empty pump is always lower than wet suction lift on a primed one, because the check balls and diaphragms seal against liquid, not against air.</p>

<p>Shinjo lists its QBY3 series with maximum suction lift of 2.5 to 3 m on the QBY3-10 and QBY3-15, 4.5 to 7.6 m on the QBY3-20 and QBY3-25, 5.4 m on the QBY3-25A, QBY3-32 and QBY3-40, and 5.48 m across the QBY3-50 through QBY3-100. Datasheet values are maxima: subtract losses across the suction strainer, elbows and any foot valve before committing to a duty. Vertical lift alone can flatter installation practice; horizontal suction runs add friction that does not show on the lift figure.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="viscosity-slows-the-stroke--24" class="scrollspy-head">Viscosity slows the stroke</h3><a class="header-anchor" href="#viscosity-slows-the-stroke--24" title="Viscosity slows the stroke" aria-label="Viscosity slows the stroke"></a></div>

<p>Published curves are drawn for water at specific gravity 1.0; as viscosity and head rise, strokes per minute fall at the same inlet air pressure (Van Ormer, n.d.). Sandpiper&#39;s weighted check balls run 30 to 60% heavier than solid rubber balls for more consistent chamber filling on thick products (Sandpiper Pump, n.d.-a).</p>

<p>Light balls may not seat quickly enough in a viscous liquid, so stainless steel or PTFE balls (or weighted composites) are the usual fix. For a percentage flow derating on your specific viscosity band, ask the manufacturer for its viscosity correction rather than guessing.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="ball-valves-flap-valves-and-particle-size--25" class="scrollspy-head">Ball valves, flap valves and particle size</h3><a class="header-anchor" href="#ball-valves-flap-valves-and-particle-size--25" title="Ball valves, flap valves and particle size" aria-label="Ball valves, flap valves and particle size"></a></div>

<p>Solids policy is decided by the check-valve type. Flap check valves can pass solids up to line size on suitably arranged pumps; ball valves pass smaller particles, because a solid has to unseat and clear a ball (Sandpiper Pump, n.d.-a).</p>

<figure class="xr-figure wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/aodd-pump-manifold-check-valve-balls-on-seats_UqT01f.png" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/f10cca90ba84b3d60cbf3b1e8ff634ce/aodd-pump-manifold-check-valve-balls-on-seats_UqT01f-320x219.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/f10cca90ba84b3d60cbf3b1e8ff634ce/aodd-pump-manifold-check-valve-balls-on-seats_UqT01f-640x439.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/f10cca90ba84b3d60cbf3b1e8ff634ce/aodd-pump-manifold-check-valve-balls-on-seats_UqT01f-700x480.webp 700w" width="700" height="480"  
      alt="Opened AODD pump manifold with two check-valve balls resting on machined stainless seats on a maintenance bench" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Opened AODD pump manifold with two check-valve balls resting on machined stainless seats on a maintenance bench' loading='lazy'  sizes="(max-width: 700px) 96vw, 700px"  />
<figcaption>An opened AODD manifold, showing two check-valve balls resting on their machined seats.</figcaption>
</figure>

<p>Shinjo lists QBY3 maximum particle size as 1.5 mm on the QBY3-10 and QBY3-15, 2.5 mm on the QBY3-20 and QBY3-25, 3.2 mm on the QBY3-25A to QBY3-40, and 6.3 mm on the QBY3-80 and QBY3-100.</p>

<blockquote class="callout callout-note">
<p><strong>Note:</strong> A pneumatic diaphragm pump tolerates dry running because it carries no seals or close-clearance rotating parts, but sustained dry running wears the diaphragms and wastes air. Graco frames it as running dry for a limited time, not indefinitely.</p>
</blockquote>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="wetted-materials-and-elastomers-temperature-chemistry-flex-life--26" class="scrollspy-head">Wetted materials and elastomers: temperature, chemistry, flex life</h2><a class="header-anchor" href="#wetted-materials-and-elastomers-temperature-chemistry-flex-life--26" title="Wetted materials and elastomers: temperature, chemistry, flex life" aria-label="Wetted materials and elastomers: temperature, chemistry, flex life"></a></div>

<p>A pneumatic diaphragm pump has three material families in contact with the fluid: the housing, the diaphragms, and the check-valve balls and seats. Each carries its own temperature limit and chemical-compatibility rating. The number that applies is always the one in the chosen pump&#39;s own documentation.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="housing-materials--27" class="scrollspy-head">Housing materials</h3><a class="header-anchor" href="#housing-materials--27" title="Housing materials" aria-label="Housing materials"></a></div>

<p>Versamatic lists AODD pump housings in metals (aluminum, cast iron, 316 stainless steel, alloy C) and plastics (polypropylene, PVDF, and acetal, including conductive grades) (Versamatic, n.d.-a). Shinjo publishes a matching list for its QBY3 series, coded by suffix: cast steel (G), <a href="https://www.shinjopump.com/aluminium-alloy-diaphragm-pump-0-30-m3-h-0-50m.html" rel="noopener" target="_blank">aluminum alloy</a> (L), <a href="https://www.shinjopump.com/double-diaphragm-pump-material-polypropylene-pp-pvdf-ptfe.html" rel="noopener" target="_blank">polypropylene</a> (S), <a href="https://www.shinjopump.com/stainless-steel-diaphragm-pump-0-50-m-delivery-lift-70m.html" rel="noopener" target="_blank">stainless steel</a> 304 (P), 316 (P316), 316L (P316L), and PTFE (F); its QBY catalog series adds <a href="https://www.shinjopump.com/cast-iron-air-operated-double-diaphragm-pump-threaded-ends.html" rel="noopener" target="_blank">cast iron</a>, PVDF, and F46-lined bodies.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="diaphragm-and-valve-elastomers--28" class="scrollspy-head">Diaphragm and valve elastomers</h3><a class="header-anchor" href="#diaphragm-and-valve-elastomers--28" title="Diaphragm and valve elastomers" aria-label="Diaphragm and valve elastomers"></a></div>

<p>Versamatic&#39;s elastomer guide compares seven common materials on temperature, flex life and abrasion resistance:</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Material</th>
			<th>Max temp</th>
			<th>Min temp</th>
			<th>Flex life</th>
			<th>Abrasion</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>EPDM</td>
			<td>138 &deg;C (280 &deg;F)</td>
			<td>-40 &deg;C (-40 &deg;F)</td>
			<td>B</td>
			<td>B+</td>
		</tr>
		<tr>
			<td>FKM</td>
			<td>177 &deg;C (350 &deg;F)</td>
			<td>-40 &deg;C (-40 &deg;F)</td>
			<td>D</td>
			<td>C</td>
		</tr>
		<tr>
			<td>Hytrel</td>
			<td>104 &deg;C (220 &deg;F)</td>
			<td>-29 &deg;C (-20 &deg;F)</td>
			<td>A</td>
			<td>A+</td>
		</tr>
		<tr>
			<td>Neoprene</td>
			<td>93 &deg;C (200 &deg;F)</td>
			<td>-23 &deg;C (-10 &deg;F)</td>
			<td>A</td>
			<td>B</td>
		</tr>
		<tr>
			<td>Nitrile</td>
			<td>88 &deg;C (190 &deg;F)</td>
			<td>-23 &deg;C (-10 &deg;F)</td>
			<td>A-</td>
			<td>B</td>
		</tr>
		<tr>
			<td>PTFE</td>
			<td>104 &deg;C (220 &deg;F)</td>
			<td>-37 &deg;C (-35 &deg;F)</td>
			<td>C-</td>
			<td>F</td>
		</tr>
		<tr>
			<td>Santoprene</td>
			<td>135 &deg;C (275 &deg;F)</td>
			<td>-40 &deg;C (-40 &deg;F)</td>
			<td>A+</td>
			<td>A+</td>
		</tr>
	</tbody>
</table></div>

<figure class="xr-figure wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa.png" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/a5b8768a80447c84e7a9905c352e1423/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa-320x320.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/a5b8768a80447c84e7a9905c352e1423/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa-640x640.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/a5b8768a80447c84e7a9905c352e1423/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa-800x800.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/a5b8768a80447c84e7a9905c352e1423/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa-1024x1024.webp 1024w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/a5b8768a80447c84e7a9905c352e1423/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa-1280x1280.webp 1280w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/a5b8768a80447c84e7a9905c352e1423/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa-1600x1600.webp 1600w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/a5b8768a80447c84e7a9905c352e1423/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa-1920x1920.webp 1920w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/a5b8768a80447c84e7a9905c352e1423/aodd-pump-diaphragm-elastomer-temperature-ranges_QX0iJa-2048x2048.webp 2048w" width="2048" height="2048"  
      alt="Horizontal range bars of AODD diaphragm elastomer operating temperatures in degrees Celsius for EPDM, FKM, Hytrel, Neoprene, Nitrile, PTFE and Santoprene" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Horizontal range bars of AODD diaphragm elastomer operating temperatures in degrees Celsius for EPDM, FKM, Hytrel, Neoprene, Nitrile, PTFE and Santoprene' loading='lazy'  sizes="(max-width: 2048px) 96vw, 2048px"  />
<figcaption>Operating temperature ranges of common AODD diaphragm elastomers, per one manufacturer&#39;s guide; limits vary by supplier.</figcaption>
</figure>

<p>Yamada, publishing the same material families, lists different maximums: Buna N (nitrile, NBR) 82 &deg;C (180 &deg;F), Neoprene 82 &deg;C (180 &deg;F), Santoprene 82 &deg;C (180 &deg;F), EPDM 100 &deg;C (212 &deg;F), PTFE 100 &deg;C (212 &deg;F), Hytrel 120 &deg;C (248 &deg;F), and Viton 120 &deg;C (248 &deg;F) (Yamada Pump, n.d.-a). The two lists differ by 4 to 57 &deg;C on the same material families, and not always in the same direction: Yamada rates Hytrel higher than Versamatic does. The limit that applies to a purchase is the one in that pump&#39;s own documentation, not a generic table.</p>

<p>Chemical compatibility for a pneumatic diaphragm pump is checked wetted part by wetted part: the housing, the diaphragms, the check-valve balls and seats, and any O-rings, each against the manufacturer&#39;s own compatibility guide. Versamatic notes that when a diaphragm fails, the pumped product reaches the center section and the air valve (Versamatic, n.d.-b).</p>

<p>Shinjo lists QBY3 diaphragms in NBR, Neoprene, EPDM, PTFE, Viton and others; its QBY catalog adds F46-lined designs.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="why-ptfe-is-not-automatically-the-safe-choice--29" class="scrollspy-head">Why PTFE is not automatically the safe choice</h3><a class="header-anchor" href="#why-ptfe-is-not-automatically-the-safe-choice--29" title="Why PTFE is not automatically the safe choice" aria-label="Why PTFE is not automatically the safe choice"></a></div>

<p>PTFE earns an A+ for chemical resistance and is often specified for aggressive acids, solvents, and food-grade duty. In Versamatic&#39;s grading it also carries a C- flex-life score and an F for abrasion, the lowest in the table (Versamatic, n.d.-b). That is the elastomer trade-off in numbers: chemical resistance at the cost of flex life and abrasion resistance. On an abrasive slurry, or on a high-cycle duty with many strokes per minute, a PTFE diaphragm reaches its replacement interval sooner than a Santoprene or Hytrel one at the same conditions. The right question is not which elastomer is strongest overall, but which one survives this fluid at this temperature and this cycle rate.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="hazardous-areas-air-driven-is-not-the-same-as-atex-rated--30" class="scrollspy-head">Hazardous areas: air-driven is not the same as ATEX-rated</h2><a class="header-anchor" href="#hazardous-areas-air-driven-is-not-the-same-as-atex-rated--30" title="Hazardous areas: air-driven is not the same as ATEX-rated" aria-label="Hazardous areas: air-driven is not the same as ATEX-rated"></a></div>

<p>An AODD pump has no electric motor, but that removes only one ignition source. The pneumatic diaphragm pump still moves flammable liquid past ball valves, cycles diaphragms thousands of times per hour, and vents air through an exhaust that can build a static charge. Air drive is not, by itself, ATEX compliance.</p>

<p>In the European Union, equipment for potentially explosive atmospheres falls under Directive 2014/34/EU (ATEX). The European Commission publishes the harmonized standards that give presumption of conformity; for non-electrical equipment such as AODD pumps these include <a href="https://www.iso.org/standard/56550.html" rel="noopener nofollow" target="_blank">EN ISO 80079-36</a> (basic method and requirements) and <a href="https://www.iso.org/standard/56553.html" rel="noopener nofollow" target="_blank">EN ISO 80079-37</a> (constructional safety, control of ignition sources, liquid immersion) (European Commission, n.d.).</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-atex-asks-of-a-pump-with-no-motor--31" class="scrollspy-head">What ATEX asks of a pump with no motor</h3><a class="header-anchor" href="#what-atex-asks-of-a-pump-with-no-motor--31" title="What ATEX asks of a pump with no motor" aria-label="What ATEX asks of a pump with no motor"></a></div>

<p>ATEX conformity is not a single stamp on the casting. AxFlow notes that the directive applies to the pump materials, the air valve assembly, and any ancillaries used in the hazardous area (solenoids, sensors, grounding hardware) (AxFlow, n.d.).</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="static-grounding-conductive-housings-and-the-exhaust--32" class="scrollspy-head">Static: grounding, conductive housings and the exhaust</h3><a class="header-anchor" href="#static-grounding-conductive-housings-and-the-exhaust--32" title="Static: grounding, conductive housings and the exhaust" aria-label="Static: grounding, conductive housings and the exhaust"></a></div>

<p>Static is the ignition source air drive still has to control. Versamatic states that ATEX-compliant AODD pumps are suitable for explosive atmospheres only when they are properly grounded per local electrical codes (Versamatic, n.d.-a). Bonding is not partial. The Blagdon/Sandpiper N50 manual requires that the pump, piping, valves, containers and any other equipment in the fluid path be earthed, and the exhaust must not be placed less than 100 mm from any non-conductive surface, because that can generate a propagating brush discharge (Sandpiper Pump, n.d.-b).</p>

<figure class="xr-figure wp-block-image"><img src="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM.webp" srcset="https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-320x214.webp 320w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-640x428.webp 640w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-800x535.webp 800w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-1024x684.webp 1024w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-1280x855.webp 1280w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-1600x1069.webp 1600w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-1920x1283.webp 1920w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-2048x1368.webp 2048w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-2560x1711.webp 2560w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-3200x2138.webp 3200w,https://img.jeawincdn.com/resource/upfiles/161/images/news/260922/resize/ae1447f0b0dbccf27897eeb7422354b8/aodd-pump-grounding-strap-earthing-solvent-transfer_t3gnDM-3520x2352.webp 3520w" width="3520" height="2352"  
      alt="Metal AODD pump in a solvent transfer area with a green-yellow grounding strap bolted from the pump body to an earthing point" class='lazyload img-responsive img-fluid' style='max-width:100%;' title='Metal AODD pump in a solvent transfer area with a green-yellow grounding strap bolted from the pump body to an earthing point' loading='lazy'  sizes="(max-width: 3520px) 96vw, 3520px"  />
<figcaption>A grounding strap bolted from a metal AODD pump to an earthing point in a solvent transfer area.</figcaption>
</figure>

<p>Confirm each of the following before a pneumatic diaphragm pump enters a classified area:</p>

<ol>
	<li>The zone classification (Zone 0, 1 or 2 for gases; 20, 21 or 22 for dusts) appears in the specification.</li>
	<li>The pump body, wetted materials and diaphragm elastomers are stated as suitable for that zone and the fluid.</li>
	<li>Every ancillary in the hazardous area (solenoid, sensor, filter-regulator, grounding strap) carries its own Ex marking.</li>
	<li>Bonding to a common ground bar is planned for the pump, piping and vessels, with the exhaust routed clear of non-conductive surfaces.</li>
	<li>Ask the supplier, Shinjo included, for the Ex marking and the EU declaration of conformity for that exact model and material build.</li>
</ol>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="when-an-aodd-pump-is-the-wrong-choice--33" class="scrollspy-head">When an AODD pump is the wrong choice</h2><a class="header-anchor" href="#when-an-aodd-pump-is-the-wrong-choice--33" title="When an AODD pump is the wrong choice" aria-label="When an AODD pump is the wrong choice"></a></div>

<p>The disadvantages of AODD pumps that matter at specification are energy, pulsating flow, the 1:1 pressure ceiling, and diaphragm wear on high-cycle duty. Compressed air is an expensive way to deliver pump power, and Graco states energy consumption can be reduced by up to 5x with an electric diaphragm pump compared with an air-operated one (Graco, n.d.).</p>

<p>A 2025 experimental study of an industrial compressed-air system cut average power consumption by 32.6% by eliminating a 0.54-bar pressure drop, reducing the compressor setpoint from 7.0 to 6.5 bar, and repairing leaks (Zaim, 2025). A 2-inch pump running continuously at 80 scfm illustrates the running cost: about $8,000 a year uncontrolled versus about $800 a year with batch control at the same duty.</p>

<p>Pulsation is the second limit. Downstream instruments, filters and metering steps can be sensitive to it, and a dampener adds cost, space and another component to maintain. The 1:1 rule is the third: a standard pneumatic diaphragm pump can give no more discharge pressure at its outlet than the air pressure at its inlet, so any duty above that ceiling points to a 2:1 design or a different pump technology. High-cycle service is the fourth, because every stroke works the diaphragm, and continuous high-hour transfer shortens its life.</p>

<p>The <a href="https://www.shinjopump.com/news/advantages-of-diaphragm-pump.html" rel="noopener" target="_blank">strengths of a pneumatic diaphragm pump</a> still stand on the duties it was designed for: it self-primes, tolerates a dry line for a limited time, handles solids and shear-sensitive liquids, and needs no electricity at the point of use (Graco, n.d.).</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Duty</th>
			<th>AODD pump</th>
			<th>Electric diaphragm</th>
			<th>Centrifugal</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Continuous high-hour transfer</td>
			<td>Poor</td>
			<td>Good</td>
			<td>Good</td>
		</tr>
		<tr>
			<td>Intermittent or portable transfer</td>
			<td>Good</td>
			<td>Acceptable</td>
			<td>Poor</td>
		</tr>
		<tr>
			<td>No power at the point of use</td>
			<td>Good</td>
			<td>Poor</td>
			<td>Poor</td>
		</tr>
		<tr>
			<td>Solids, slurry or shear-sensitive liquids</td>
			<td>Good</td>
			<td>Good</td>
			<td>Poor</td>
		</tr>
		<tr>
			<td>Low viscosity, steady flow at high head</td>
			<td>Poor</td>
			<td>Acceptable</td>
			<td>Good</td>
		</tr>
		<tr>
			<td>Tight flow control or metering</td>
			<td>Poor</td>
			<td>Good</td>
			<td>Acceptable</td>
		</tr>
	</tbody>
</table></div>

<p>Where an electric replacement fits the same envelope, <a href="https://www.shinjopump.com/dby-motor-driven-diaphragm-pump-flow-capacity-0-5-16-m3-h.html" rel="noopener" target="_blank">Shinjo&#39;s DBY motor-driven diaphragm pump</a> shares the QBY3 series&#39; hydraulic performance and only the drive differs. Where a centrifugal is the better fit, see <a href="https://www.shinjopump.com/news/how-to-select-a-centrifugal-pump.html" rel="noopener" target="_blank">how to select a centrifugal pump</a>.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="the-aodd-specification-to-send-with-an-rfq--34" class="scrollspy-head">The AODD specification to send with an RFQ</h2><a class="header-anchor" href="#the-aodd-specification-to-send-with-an-rfq--34" title="The AODD specification to send with an RFQ" aria-label="The AODD specification to send with an RFQ"></a></div>

<p>A disciplined data sheet lets buyers <a href="https://www.shinjopump.com/diaphragm-pumps.html" rel="noopener" target="_blank">compare air-operated and motor-driven diaphragm pump models</a> on equal footing.</p>

<p>A request for quotation for a pneumatic diaphragm pump should state 13 fields: the liquid, temperature, viscosity, solids, flow range, discharge pressure, suction arrangement, air available at the pump, duty cycle, hazardous-area class, connections, materials and documents. Air pressure and SCFM at the pump matter most, because together they cap both flow and discharge pressure.</p>

<div style="min-width:85%;overflow:auto;"><table class=" table" style="max-width:100%;">
	<thead>
		<tr>
			<th>Field</th>
			<th>What to state</th>
			<th>Why it matters</th>
		</tr>
	</thead>
	<tbody>
		<tr>
			<td>Liquid and concentration</td>
			<td>Chemical name, percent by weight</td>
			<td>Sets wetted-part compatibility</td>
		</tr>
		<tr>
			<td>Temperature range</td>
			<td>Normal and maximum in &deg;C (&deg;F)</td>
			<td>Caps elastomer choice</td>
		</tr>
		<tr>
			<td>Viscosity and specific gravity</td>
			<td>cP and SG at duty temperature</td>
			<td>Sets stroke rate and head conversion</td>
		</tr>
		<tr>
			<td>Solids</td>
			<td>Size (mm), percent by volume, abrasive or not</td>
			<td>Sets valve type and housing wear</td>
		</tr>
		<tr>
			<td>Flow range</td>
			<td>L/min and US gpm</td>
			<td>Locates the duty on the curve</td>
		</tr>
		<tr>
			<td>Discharge pressure or head</td>
			<td>Normal and maximum, in bar</td>
			<td>Sits below the air pressure per the 1:1 rule</td>
		</tr>
		<tr>
			<td>Suction arrangement</td>
			<td>Flooded or lift, line length and size</td>
			<td>Sets priming and dry-lift margin</td>
		</tr>
		<tr>
			<td>Air available at the pump</td>
			<td>Pressure (bar) and volume (SCFM)</td>
			<td>Caps flow and discharge pressure</td>
		</tr>
		<tr>
			<td>Duty cycle</td>
			<td>Hours per day, continuous or batch</td>
			<td>Drives running cost and diaphragm wear</td>
		</tr>
		<tr>
			<td>Hazardous-area class</td>
			<td>Zone and gas group, or none</td>
			<td>Selects Ex marking and grounding</td>
		</tr>
		<tr>
			<td>Connections</td>
			<td>Standard and size (DN, NPT, BSP)</td>
			<td>Ensures pipe and flange fit</td>
		</tr>
		<tr>
			<td>Materials</td>
			<td>Housing, diaphragms, balls and seats</td>
			<td>Chemistry and flex life</td>
		</tr>
		<tr>
			<td>Required documents</td>
			<td>Curve, datasheet, DoC, Ex marking</td>
			<td>Basis for audit and approval</td>
		</tr>
	</tbody>
</table></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="pulsation-say-whether-the-process-can-take-it--35" class="scrollspy-head">Pulsation: say whether the process can take it</h3><a class="header-anchor" href="#pulsation-say-whether-the-process-can-take-it--35" title="Pulsation: say whether the process can take it" aria-label="Pulsation: say whether the process can take it"></a></div>

<p>An AODD pump&#39;s discharge pulses. The amount of pulsation depends on pump size, speed, air supply pressure, discharge pressure, fluid viscosity, piping and distance to downstream equipment (Yamada Pump, n.d.-b); a pulsation dampener is matched to the pump model and port size, flow rate, discharge pressure, viscosity and chemical compatibility (Yamada Pump, n.d.-b). State in the RFQ whether the downstream meter, filler, spray head or filter can accept pulsating flow, or whether a pulsation dampener belongs in the scope of supply.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="frequently-asked-questions--36" class="scrollspy-head">Frequently Asked Questions</h2><a class="header-anchor" href="#frequently-asked-questions--36" title="Frequently Asked Questions" aria-label="Frequently Asked Questions"></a></div>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-is-a-pneumatic-diaphragm-pump--37" class="scrollspy-head">What is a pneumatic diaphragm pump?</h3><a class="header-anchor" href="#what-is-a-pneumatic-diaphragm-pump--37" title="What is a pneumatic diaphragm pump?" aria-label="What is a pneumatic diaphragm pump?"></a></div>

<p>A pneumatic diaphragm pump, also called an AODD pump, is a positive displacement pump driven by compressed air. An air valve shifts two diaphragms joined by a shaft, so one chamber discharges while the other fills, and four check valves keep the liquid moving one way.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="do-diaphragm-pumps-need-air--38" class="scrollspy-head">Do diaphragm pumps need air?</h3><a class="header-anchor" href="#do-diaphragm-pumps-need-air--38" title="Do diaphragm pumps need air?" aria-label="Do diaphragm pumps need air?"></a></div>

<p>Air-operated (AODD) pumps need compressed air; the air side is what drives the diaphragms and sets the flow. Electric (motor-driven) diaphragm pumps do not need compressed air, since a motor and gearbox move the diaphragms instead. The choice between the two is a duty decision, not a technology preference.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-are-the-disadvantages-of-aodd-pumps--39" class="scrollspy-head">What are the disadvantages of AODD pumps?</h3><a class="header-anchor" href="#what-are-the-disadvantages-of-aodd-pumps--39" title="What are the disadvantages of AODD pumps?" aria-label="What are the disadvantages of AODD pumps?"></a></div>

<p>The disadvantages that matter at specification are the energy cost of compressed air, pulsating discharge flow, the 1:1 pressure ceiling that caps discharge at the air pressure supplied, and diaphragm wear on high-cycle continuous duty. Each is a duty question, not a defect in the pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="are-aodd-pumps-self-priming--40" class="scrollspy-head">Are AODD pumps self-priming?</h3><a class="header-anchor" href="#are-aodd-pumps-self-priming--40" title="Are AODD pumps self-priming?" aria-label="Are AODD pumps self-priming?"></a></div>

<p>Yes. An AODD pump can evacuate air from the suction line and prime itself. Wetting the pump before start-up improves priming markedly, because a wet stroke seats the check balls better than a dry one. Dry suction lift is lower than wet suction lift on the same pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="how-much-air-does-an-aodd-pump-use--41" class="scrollspy-head">How much air does an AODD pump use?</h3><a class="header-anchor" href="#how-much-air-does-an-aodd-pump-use--41" title="How much air does an AODD pump use?" aria-label="How much air does an AODD pump use?"></a></div>

<p>A generic 2-inch AODD pump uses 90 to 120 scfm at an average 95 psig inlet (Van Ormer, n.d.). Air use rises with flow and discharge pressure and falls with viscosity and back pressure. Size the compressor with hp = SCFM / 4.5 (PSG Blackmer, 2022), then round up to the next 5 hp step.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="what-is-the-maximum-air-pressure-for-an-aodd-pump--42" class="scrollspy-head">What is the maximum air pressure for an AODD pump?</h3><a class="header-anchor" href="#what-is-the-maximum-air-pressure-for-an-aodd-pump--42" title="What is the maximum air pressure for an AODD pump?" aria-label="What is the maximum air pressure for an AODD pump?"></a></div>

<p>Standard 1:1 ratio AODD pumps are rated to 125 psi (8.6 bar) (Versamatic, n.d.-a). Fit a filter-regulator upstream where the plant air could exceed that ceiling. Discharge pressure cannot exceed the air pressure applied at the inlet, so the air supply is what caps the achievable duty.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="how-do-you-size-an-aodd-pump--43" class="scrollspy-head">How do you size an AODD pump?</h3><a class="header-anchor" href="#how-do-you-size-an-aodd-pump--43" title="How do you size an AODD pump?" aria-label="How do you size an AODD pump?"></a></div>

<p>Read the manufacturer&#39;s performance curve at your duty. Draw a horizontal line from the discharge pressure and a vertical line from the required flow; their intersection sits on one air-inlet-pressure curve and near one air-consumption line, giving the SCFM the pump will draw and the compressor it needs.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h3 id="can-a-pneumatic-diaphragm-pump-run-dry--44" class="scrollspy-head">Can a pneumatic diaphragm pump run dry?</h3><a class="header-anchor" href="#can-a-pneumatic-diaphragm-pump-run-dry--44" title="Can a pneumatic diaphragm pump run dry?" aria-label="Can a pneumatic diaphragm pump run dry?"></a></div>

<p>Yes, briefly. An AODD pump tolerates dry running because it has no shaft seals or close-clearance rotating parts. Sustained dry running still wears the diaphragms and wastes air, so treat it as an occasional condition when the tank empties, not as a normal operating point.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="conclusion--45" class="scrollspy-head">Conclusion</h2><a class="header-anchor" href="#conclusion--45" title="Conclusion" aria-label="Conclusion"></a></div>

<p>A pneumatic diaphragm pump is specified from the air side, and the rest of the datasheet follows from that read. The duty converts to bar first, then the curve is read at the flow and discharge pressure to fix the inlet air pressure and the SCFM the pump will draw. The compressor and the air line must be able to deliver that flow at the required inlet pressure at the pump, not at the header. The reading is derated for suction lift, viscosity and solids, using the manufacturer&#39;s correction where one is published and asking for it where it is not.</p>

<p>Elastomers are chosen from the pump&#39;s own temperature limits and its wetted-parts compatibility guide, because manufacturers publish different figures for the same material family. Hazardous-area service and continuous high-hour duty are separate decisions: an AODD pump in a classified zone needs its Ex marking and grounding, and long running hours often justify an electric diaphragm pump.</p>

<div class="scrollspy-head-wrapper" style="position:relative;margin-bottom:1.25em;margin-top:1rem;"><h2 id="references--46" class="scrollspy-head">References</h2><a class="header-anchor" href="#references--46" title="References" aria-label="References"></a></div>

<ol>
	<li>Zaim, A. (2025). Industrial compressed air system optimization: Experimental evaluation of energy efficiency and sustainability gains. Processes, 13(11), 3590. <a href="https://doi.org/10.3390/pr13113590" rel="noopener nofollow" target="_blank">https://doi.org/10.3390/pr13113590</a></li>
	<li>European Commission. (n.d.). Equipment for explosive atmospheres (ATEX): Directive 2014/34/EU. Retrieved September 19, 2026, from <a href="https://single-market-economy.ec.europa.eu/single-market/european-standards/harmonised-standards/equipment-explosive-atmospheres-atex_en" rel="noopener nofollow" target="_blank">https://single-market-economy.ec.europa.eu/single-market/european-standards/harmonised-standards/equipment-explosive-atmospheres-atex_en</a></li>
	<li>U.S. Energy Information Administration. (2026). Average retail price of electricity to ultimate customers by end-use sector: Industrial, June 2026 [Data set]. <a href="https://www.eia.gov/electricity/data/browser/#/topic/7?agg=0,1&amp;geo=g&amp;freq=M" rel="noopener nofollow" target="_blank">https://www.eia.gov/electricity/data/browser/#/topic/7?agg=0,1&amp;geo=g&amp;freq=M</a></li>
	<li>PSG Blackmer. (2022, October 27). How understanding AODD pump performance curves optimizes operations. <a href="https://www.psgdover.com/blackmer/news/article/2022/10/27/how-understanding-aodd-pump-performance-curves-optimizes-operations" rel="noopener nofollow" target="_blank">https://www.psgdover.com/blackmer/news/article/2022/10/27/how-understanding-aodd-pump-performance-curves-optimizes-operations</a></li>
	<li>All-Flo Pump. (n.d.). With minimized compressed air usage, AODDPs provide an energy-efficient solution. Pumps &amp; Systems. Retrieved September 19, 2026, from <a href="https://www.pumpsandsystems.com/article/minimized-compressed-air-usage-aoddps-provide-energy-efficient-solution" rel="noopener nofollow" target="_blank">https://www.pumpsandsystems.com/article/minimized-compressed-air-usage-aoddps-provide-energy-efficient-solution</a></li>
	<li>Global Pumps. (n.d.). Reading an air-operated double-diaphragm pump performance curve. Retrieved September 19, 2026, from <a href="https://www.globalpumps.com/blog/reading-an-air-operated-double-diaphragm-pump-performance-curve" rel="noopener nofollow" target="_blank">https://www.globalpumps.com/blog/reading-an-air-operated-double-diaphragm-pump-performance-curve</a></li>
	<li>Yamada Pump. (n.d.-a). What is a diaphragm? AODD pump diaphragm materials. Retrieved September 19, 2026, from <a href="https://www.yamadapump.com/what-is-a-diaphragm" rel="noopener nofollow" target="_blank">https://www.yamadapump.com/what-is-a-diaphragm</a></li>
	<li>Yamada Pump. (n.d.-b). What is a pulsation dampener? AODD pump flow &amp; pressure control. Retrieved September 19, 2026, from <a href="https://www.yamadapump.com/what-is-a-pulsation-dampener" rel="noopener nofollow" target="_blank">https://www.yamadapump.com/what-is-a-pulsation-dampener</a></li>
	<li>Versamatic. (n.d.-a). Key AODD pump performance specifications explained. Retrieved September 19, 2026, from <a href="https://www.versamatic.com/blog/key-aodd-pump-performance-specifications-explained" rel="noopener nofollow" target="_blank">https://www.versamatic.com/blog/key-aodd-pump-performance-specifications-explained</a></li>
	<li>Versamatic. (n.d.-b). Your guide to AODD pump elastomer material performance properties. Retrieved September 19, 2026, from <a href="https://www.versamatic.com/blog/your-guide-to-aodd-pump-elastomer-material-performance-properties" rel="noopener nofollow" target="_blank">https://www.versamatic.com/blog/your-guide-to-aodd-pump-elastomer-material-performance-properties</a></li>
	<li>Van Ormer, H. (n.d.). Missed demand-side opportunities part 6: Look to AODD pumps to lower compressed air demand. Compressed Air Best Practices. Retrieved September 19, 2026, from <a href="https://www.airbestpractices.com/system-assessments/end-uses/missed-demand-side-opportunities-part-6-look-aodd-pumps-lower-compressed" rel="noopener nofollow" target="_blank">https://www.airbestpractices.com/system-assessments/end-uses/missed-demand-side-opportunities-part-6-look-aodd-pumps-lower-compressed</a></li>
	<li>Sandpiper Pump. (n.d.-a). Flap valve vs. ball valve AODD pumps: Understand which is right for your application. Retrieved September 19, 2026, from <a href="https://www.sandpiperpump.com/blog/flap-valve-vs.-ball-valve-aodd-pumps-understand-which-is-right-for-your-application" rel="noopener nofollow" target="_blank">https://www.sandpiperpump.com/blog/flap-valve-vs.-ball-valve-aodd-pumps-understand-which-is-right-for-your-application</a></li>
	<li>Sandpiper Pump. (n.d.-b). N50 &amp; X50 hygienic B5002 series service and operating manual. Retrieved September 19, 2026, from <a href="https://www.sandpiperpump.com/hubfs/N50_X50_Hygienic.pdf" rel="noopener nofollow" target="_blank">https://www.sandpiperpump.com/hubfs/N50_X50_Hygienic.pdf</a></li>
	<li>AxFlow. (n.d.). ATEX AODD pumps. Retrieved September 19, 2026, from <a href="https://www.axflow.com/en-gb/applications/technical-support/pump-technologies/certificates-and-approvals/atex/atex-aodd-pumps" rel="noopener nofollow" target="_blank">https://www.axflow.com/en-gb/applications/technical-support/pump-technologies/certificates-and-approvals/atex/atex-aodd-pumps</a></li>
	<li>Graco. (n.d.). How does a diaphragm pump work and what is it used for? Benefits of an electric diaphragm pump. Retrieved September 19, 2026, from <a href="https://www.graco.com/us/en/in-plant-manufacturing/solutions/articles/benefits-of-an-electric-diaphragm-pump.html" rel="noopener nofollow" target="_blank">https://www.graco.com/us/en/in-plant-manufacturing/solutions/articles/benefits-of-an-electric-diaphragm-pump.html</a></li>
</ol>

<hr />
<p class="article-signature"><em>Last reviewed and updated: September 2026. Author: Shinjo Pump engineering team. For pump selection support or a quotation on your duty point, <a href="https://www.shinjopump.com/contact.html" rel="noopener" target="_blank">contact our team</a>.</em></p>
</div>