    Abstract

    A positive displacement pump traps a fixed volume of liquid and pushes it out with each stroke or shaft revolution (U.S. Department of Energy & Hydraulic Institute, 2006). A US Department of Energy and Hydraulic Institute sourcebook calls this a “collapsing volume” action: the pump squeezes liquid by shrinking the space that holds it (U.S. Department of Energy & Hydraulic Institute, 2006). So flow follows speed, while the system’s resistance sets the pressure (U.S. Department of Energy & Hydraulic Institute, 2006). Delivered flow equals displacement times speed times volumetric efficiency (Gaydon, 2022; Hydraulic Institute, n.d.); the shortfall is slip, the pump’s internal leakage (Gaydon, 2022). Slip grows with differential pressure and shrinks as viscosity increases (Blodgett, n.d.). Delivered flow therefore falls as pressure climbs, and the loss is largest with thin liquids.

    Positive displacement pump illustration: a horizontal progressing cavity pump and geared motor on one baseplate, with the stator cut away to show the rotor
    A progressing cavity pump: the geared motor at one end, suction into the housing beside it, and discharge at the far end of the stator, cut away here to show the rotor.

    This guide is for procurement, project and maintenance engineers choosing or specifying a PD pump. Specifying one means choosing the family (reciprocating, rotary or controlled-volume metering) and the standard that goes with it, constant or variable displacement, relief protection and the flow-control method, the suction margin (NPIP and acceleration head) and dry-run protection, then checking whether a centrifugal pump fits the duty better.

    Key Takeaways

    • A positive displacement pump, or PD pump, traps and moves a fixed volume per stroke or revolution, less slip.
    • Delivered flow is displacement times speed times volumetric efficiency. Slip (internal leakage) rises with pressure and falls with viscosity.
    • Worked example: 1.0 L/rev at 400 r/min delivers 22.1 m3/h (97.2 US gpm) at 92% volumetric efficiency.
    • The Hydraulic Institute (HI) names three PD families: reciprocating, rotary and controlled-volume metering, itself a reciprocating design.
    • Never throttle the discharge to control flow. HI calls a relief valve mandatory on reciprocating power pumps, placed ahead of any other valve.
    • Example acceleration head: 1.9 m (6.2 ft) on a triplex suction line, 0.3 m with a dampener.
    • For viscous fluids both types can handle, HI says PD is often 10 to 40 points more energy-efficient than centrifugal.

    Table of Contents

    Positive displacement pump definition

    A positive displacement pump (PD pump) traps a fixed volume of liquid in a chamber and forces that volume into the discharge line with each stroke or shaft revolution (U.S. Department of Energy & Hydraulic Institute, 2006). Its flow follows its speed, and its discharge pressure is whatever the system’s resistance demands (U.S. Department of Energy & Hydraulic Institute, 2006). Delivered flow is the displaced volume less any internal leakage, called slip (Gaydon, 2022).

    Per the Hydraulic Institute (HI) Data Tool, “Positive displacement pumps are a class which trap and move a volume of fluid with each shaft rotation” (Hydraulic Institute, 2024).

    HI divides that class into reciprocating types, which use pistons, plungers and diaphragms, and rotary types, which use meshing components such as screws, gears, lobes and vanes (Hydraulic Institute, 2024). Rotodynamic pumps work differently. They impart energy to the liquid through a rotating impeller, propeller or rotor (Hydraulic Institute, 2024).

    The U.S. Department of Energy and Hydraulic Institute pumping sourcebook (2nd edition, 2006) says PD pumps “pressurize fluid with a collapsing volume action” (U.S. Department of Energy & Hydraulic Institute, 2006) and “have a fixed displacement volume. Consequently, the flow rates they generate are directly proportional to their speed. The pressures they generate are determined by the system’s resistance to this flow” (U.S. Department of Energy & Hydraulic Institute, 2006).

    An HI overview of the technology, published in Plant Services, states the consequence: “PD pumps, at constant speed, are constant-flow devices, whereas centrifugal pumps are variable-flow devices” (Hydraulic Institute PD Pump Members, 2011). To define positive displacement pump operation in one sentence, the screw-pump maker KRAL puts the contrast this way: a centrifugal pump creates pressure and flow results, while a positive displacement design creates flow and pressure results.

    Constant flow is an approximation. A common shorthand says the flow stays the same regardless of pressure, and that overstates it. An HI article on viscosity words it more carefully: the pump displaces a certain volume with every revolution of the shaft, “minus any volumetric leakage (slip)” (Gaydon, 2022). Slip grows as differential pressure rises, so delivered flow falls as discharge pressure climbs (Blodgett, n.d.). A more viscous liquid reduces slip and raises volumetric efficiency (Gaydon, 2022). Clearances and wear change it too (Blodgett, n.d.).

    The name describes the mechanism. “Positive” refers to how the liquid is handled: it is enclosed in a shrinking space and forced out, rather than accelerated by a spinning impeller. The DOE sourcebook says the pumps “squeeze fluid by decreasing the volume that contains it” (U.S. Department of Energy & Hydraulic Institute, 2006). In practice, a flow figure for this kind of pump means little unless it states the speed, the differential pressure and the liquid viscosity it applies to.

    Glossary

    • Slip: internal leakage flow, the difference between the theoretical and the actual volume per shaft revolution (Gaydon, 2022).
    • Volumetric efficiency: the actual volume per shaft revolution over the theoretical volume per revolution (Gaydon, 2022).
    • Rotodynamic pump: a pump, such as a centrifugal pump, that imparts energy to the liquid through a rotating impeller, propeller or rotor (Hydraulic Institute, 2024).
    • Constant displacement pump: a positive displacement pump whose volume per revolution is fixed by design (Gannon, n.d.); fixed displacement means the same thing.
    • Variable displacement pump: a pump that can change its volume per revolution while it runs (Gannon, n.d.).
    • Controlled-volume metering pump (CVMP): a reciprocating positive displacement pump configured to dispense an accurate volume of liquid during a specified time period (Hydraulic Institute PD Pump Members, 2011).
    • Deadheading: running a pump against a closed discharge.
    • NPIP: net positive inlet pressure, “the absolute pressure required at the inlet of the pump to prevent cavitation”; NPIPA is what the system supplies, NPIPR what the pump requires (Viking Pump, n.d.).
    • Acceleration head: inlet pressure a reciprocating pump loses (Henshaw, n.d.) as its pulsing suction flow speeds up and slows down with each stroke.

    How does a positive displacement pump work?

    A positive displacement pump works by trapping a fixed volume of liquid and forcing it out of the discharge with each stroke or shaft revolution (U.S. Department of Energy & Hydraulic Institute, 2006). Its delivered flow is set by that displacement and the speed, less an internal leakage called slip (Gaydon, 2022), while the system’s resistance sets the pressure (U.S. Department of Energy & Hydraulic Institute, 2006).

    Inside a reciprocating PD pump, a moving piston forces liquid out of a closed cylinder through inlet and outlet valves (Hydraulic Institute PD Pump Members, 2011). In a rotary pump, a rotating element inside a pumping chamber drives the liquid, and there are no inlet or discharge valves (Hydraulic Institute PD Pump Members, 2011).

    Animated diagram of a progressing cavity pump: the rotor slides along the stator slot as it turns, and sealed cavities travel from suction to discharge
    Inside a progressing cavity pump: as the rotor turns, its cross-section slides along the stator slot, and the sealed cavities between rotor and stator travel from suction to discharge.

    Flow equals displacement times speed, less slip

    The simplest way to explain positive displacement pump behavior is one line of arithmetic. For controlled-volume metering pumps, the Hydraulic Institute (HI) writes it as “Rate of flow = Displacement x Cycles per unit of time x Volumetric efficiency” (Hydraulic Institute, n.d.). HI defines volumetric efficiency as the actual volume per shaft revolution over the theoretical volume per revolution; the difference is leakage flow known as slip (Gaydon, 2022). Theoretical capacity is directly proportional to speed (Gaydon, 2022).

    HI states that internal slip is affected by viscosity and pressure (Gaydon, 2022), and that higher viscosity “reduces the amount of slip and increases the volumetric efficiency” (Gaydon, 2022). Blodgett, writing in Pumps & Systems, states that slip does not increase with speed, so a rotary pump gains volumetric efficiency as it runs faster, though faster running brings abrasive wear, shear and, with very viscous liquids, incomplete cavity filling (Blodgett, n.d.). Slip does rise with differential pressure, more so with flexible or compressible parts, and it depends on clearances and wear (Blodgett, n.d.).

    Shinjo’s G-type single-screw pump table lists the G20-1 at 960 r/min delivering 0.96 m3/h (4.2 US gpm) at 0.3 MPa (43.5 psi) and 0.8 m3/h (3.5 US gpm) at 0.6 MPa (87 psi). Same pump, same speed: the flow lost at the higher pressure is extra slip.

    Viscosity can change slip by a wide margin. In one manufacturer’s 2014 test of a single rubber-lobed rotary lobe pump at 300 r/min and 25 psi (1.7 bar) differential, slip was 24.5% of the displaced quantity on a 1 cP liquid and 2.8% on a 401 cP liquid (Blodgett, n.d.). The figures describe that one pump only.

    A worked example

    Take a displacement pump of 1.0 L (61.0 in3) per revolution at 400 r/min; the inputs are illustrative, not a Shinjo model. Theoretical flow is 400 L/min, or 24.0 m3/h (105.7 US gpm). Assuming 92% volumetric efficiency, the pump delivers 368 L/min, or 22.1 m3/h (97.2 US gpm). Slip is the 32 L/min difference, 1.92 m3/h (8.5 US gpm).

    At 200 r/min against the same pressure and liquid, slip is held at 32 L/min, since slip does not rise with speed (Blodgett, n.d.). Theoretical flow halves to 200 L/min while delivered flow falls to 168 L/min, or 10.08 m3/h (44.4 US gpm). Volumetric efficiency drops from 92% to 84%.

    Quantity At 400 r/min At 200 r/min
    Theoretical flow 400 L/min 200 L/min
    Delivered flow 368 L/min 168 L/min
    Slip 32 L/min 32 L/min
    Volumetric efficiency 92% 84%
    Bar chart: an illustrative 1.0 L/rev pump delivers 368 of 400 L/min at 400 r/min and 168 of 200 L/min at 200 r/min
    In the worked example slip stays at 32 L/min, so halving the speed lowers volumetric efficiency from 92% to 84%.

    Real slip also depends on pressure, viscosity, wear and clearances. HI states that theoretical horsepower is proportional to speed and pressure (Gaydon, 2022). The delivered 368 L/min is 0.006133 m3/s; at 10 bar (145 psi) differential, hydraulic power is 0.006133 m3/s x 1,000,000 Pa = 6.13 kW (8.2 hp) before mechanical and volumetric losses.

    HI advises consulting the manufacturer on viscous performance (Hydraulic Institute, n.d.), so a PD pump inquiry should ask for delivered flow at the duty’s differential pressure and viscosity.

    Types of positive displacement pump and their standards

    The Hydraulic Institute (HI) PD Pump Members name three major categories of positive displacement pump: reciprocating, rotary and the controlled-volume metering pump (CVMP) (Hydraulic Institute PD Pump Members, 2011). HI’s Data Tool divides the same class into two, reciprocating and rotary (Hydraulic Institute, 2024). Both counts are correct. HI describes metering pumps as “reciprocating positive-displacement pumps configured to dispense an accurate volume of liquid during a specified time period” (Hydraulic Institute PD Pump Members, 2011), so the third category sits inside the first. The split still matters to a buyer, because the standards follow it.

    Family Examples Standards (current edition)
    Reciprocating power Piston and plunger power pumps, simplex to multiplex (Hydraulic Institute, 2024) HI 6.1-6.5-2015, reaffirmed 2020; API 674 3rd ed. 2010, reaffirmed 2026; ISO 13710:2004, confirmed 2026
    Air-operated (reciprocating) Air-operated diaphragm and bellows pumps (Hydraulic Institute, 2024) ANSI/HI 10.1-10.5 (2021) (Hydraulic Institute, 2024)
    Controlled-volume metering Diaphragm and piston metering pumps (Hydraulic Institute, 2024) ANSI/HI 7.1-7.5-2023; API 675 3rd ed. 2012, reaffirmed 2021
    Rotary Gear, lobe, vane, screw, peristaltic, circumferential piston and axial piston pumps (Hydraulic Institute, 2024) ANSI/HI 3.1-3.5-2021; ANSI/HI 3.6 rotary pump tests (2022); API 676 4th ed. 2022; ISO 14847:1999 (currently under systematic review)
    Cutaway illustration of three rotary positive displacement pumps: an external gear pump, a lobe pump and a progressing cavity pump
    Three rotary designs in cutaway: an external gear pump, a lobe pump with its two timed rotors, and a progressing cavity pump. Each carries trapped liquid from inlet to outlet.

    Reciprocating: piston, plunger and diaphragm

    A reciprocating PD pump moves liquid with a piston, plunger or diaphragm (Hydraulic Institute, 2024). HI files air-operated diaphragm pumps under reciprocating (Hydraulic Institute, 2024), with their own standard, ANSI/HI 10.1-10.5 (Hydraulic Institute, 2024). API 674 covers reciprocating pumps for petroleum, chemical and gas industry services and excludes controlled-volume, hydraulically driven and rotary pumps. ISO 13710 does not apply to controlled-volume or rotary pumps either, and ISO confirmed its 2004 edition in 2026.

    Shinjo’s diaphragm range belongs to this family: Shinjo lists air-operated QBY and motor-driven DBY models.

    Rotary: gear, lobe, vane, screw and peristaltic

    HI’s Data Tool lists external and internal gear, single and three lobe, flexible and sliding vane, circumferential piston, flexible tube (peristaltic), and screw pumps in single-screw (progressing cavity), two-screw (timed) and three-screw (untimed) forms (Hydraulic Institute, 2024). It also places the axial piston pump under rotary, not reciprocating (Hydraulic Institute, 2024). API 676 covers rotary process pumps and excludes controlled-volume, hydraulically driven and reciprocating pumps. ISO 14847:1999 (currently under systematic review) sets technical requirements for rotary positive displacement pumps.

    The screw pumps Shinjo lists are single-screw (progressing cavity) designs. Shinjo describes its G type as a rotary displacement pump whose main working parts are an eccentric screw (rotor) and a fixed bush (stator). Shinjo lists 0.6 MPa (87 psi) outlet pressure for a single-stage G type and 1.2 MPa (174 psi) for a dual-stage one, each added stage contributing 0.6 MPa. Shinjo’s range also includes a gear oil pump.

    Controlled-volume metering pumps

    ANSI/HI 7.1-7.5-2023 treats controlled-volume metering pumps, also called proportioning, chemical injection, chemical feed or dosing pumps, as reciprocating pumps for chemical injection, proportional blending or metered transfer. API 675 covers reciprocating controlled-volume pumps of hydraulic-diaphragm or packed-plunger design; rotary positive displacement pumps and diaphragm pumps that use direct mechanical actuation are excluded.

    API’s positive displacement pump standards for the petroleum, chemical and gas industries line up with HI’s three categories: API 674 (3rd edition, 2010, reaffirmed 2026) for reciprocating pumps, API 675 (3rd edition, 2012, reaffirmed 2021) for controlled-volume metering pumps and API 676 (4th edition, 2022) for rotary pumps. Both API 674 and API 676 exclude controlled-volume pumps.

    Get started here

    At a fixed speed, a screw pump delivers less flow as differential pressure rises, and the loss is larger on a thin liquid, so a flow figure on a quote means little without the pressure and viscosity it applies to. Shinjo quotes its screw pump range against a stated duty point: send the liquid, its viscosity at the lowest pumping temperature, the flow you need and the differential pressure, and ask for delivered flow at that duty. See Shinjo’s screw pumps

    Constant displacement pump vs variable displacement pump

    A constant displacement pump is a positive displacement pump whose volume per revolution is fixed by design; a variable displacement pump can change that volume while it runs (Gannon, n.d.). “Constant displacement” is the hydraulics term, and fixed displacement means the same thing.

    Mobile Hydraulic Tips notes that a fixed pump’s displacement does not change “regardless of how the pump is controlled or what occurs downstream” (Gannon, n.d.). HK Hydraulik’s glossary puts the result in flow terms: a constant pump delivers “a virtually constant volume flow at a given speed,” and “the actual volume flow depends directly on the speed of the drive motor”. Mobile Hydraulic Tips adds: “If you need less flow than the pump is rated for, the excess flow must be diverted or relieved to tank” (Gannon, n.d.). Panagon Systems, a hydraulic pump remanufacturer, names external and internal gear pumps as fixed-displacement examples and says vane and piston pumps can also be fixed.

    A variable displacement pump changes its displacement manually, hydraulically or electronically (Gannon, n.d.). In a variable axial piston pump, the swashplate angle sets piston stroke, and a pressure compensator reduces that angle when downstream pressure exceeds its setting (Gannon, n.d.). Variable vane pumps shift the cam ring instead (Gannon, n.d.). That flexibility adds mechanism, and Panagon describes variable displacement pumps as more complex. The difference is where surplus flow goes: a compensated pump trims its own output, while a fixed pump needs an external path for it.

    In process duty, gear, lobe and screw pumps have a fixed displacement volume, so flow from such a PD pump is changed by speed or by bypass (Hydraulic Institute PD Pump Members, 2011; U.S. Department of Energy & Hydraulic Institute, 2006). Shinjo, for example, states that flow on its G type single screw pump is adjusted “by changing the speed”, and its screw, diaphragm and gear pump pages list no variable-displacement model.

    On the process side, variable displacement appears in the controlled-volume metering pump, a reciprocating positive displacement pump that varies its effective displacement through stroke length (Hydraulic Institute, n.d.; Hydraulic Institute PD Pump Members, 2011). The Hydraulic Institute says flow against stroke-length setting is linear but “not necessarily proportional in that 50% stroke setting may not equal 50% flow” (Hydraulic Institute, n.d.).

    Relief valves and flow control on a PD pump

    Closing a discharge valve does not cut the flow of a positive displacement pump; pressure rises instead. With all downstream valves closed, the US Department of Energy (DOE) says pressure builds “until a relief valve lifts, a pipe or fitting ruptures, or the pump motor stalls” (U.S. Department of Energy & Hydraulic Institute, 2006).

    Illustration of a gear pump with a return-to-tank relief valve teed off the discharge ahead of the first isolation valve
    The relief valve tees off the discharge close to the pump, ahead of the isolation valve, and returns relieved liquid to the supply tank.

    Why the discharge is never throttled

    Throttling a PD pump gives no flow control either. Pressure rises, and delivered flow falls only by the added slip (Blodgett, n.d.; U.S. Department of Energy & Hydraulic Institute, 2006). DOE warns that relying on relief valves “adds an element of risk” (U.S. Department of Energy & Hydraulic Institute, 2006), and Viking Pump states that pressure relief valves are neither flow control valves nor pressure regulators (Hall, n.d.). Viking adds that they are there only to prevent overpressure in an upset (Hall, n.d.).

    Animated piping diagram: the isolation valve on a gear pump discharge closes, pressure climbs to the set point, and the spring-loaded relief valve lifts and returns the flow to the supply tank
    If a valve downstream of the pump closes, discharge pressure climbs until the relief valve lifts and returns the flow to the supply tank. The relief valve protects against upsets; it does not control flow.

    Sizing and placing the relief valve

    For reciprocating power pumps, the Hydraulic Institute (HI) calls a discharge relief valve mandatory (Hydraulic Institute, n.d.). Sized for the pump’s flow and set to open above the operating discharge pressure, it belongs in the discharge line close to the pump, ahead of any other valves (Hydraulic Institute, n.d.). Spring-loaded valves usually need 10% to 25% above set pressure to open fully, depending on spring design (Hydraulic Institute, n.d.).

    Viking Pump says rotary positive displacement pumps such as gear and lobe designs must have overpressure protection (Hall, n.d.). For its pumps with internal relief valves, Viking says cracking pressure can be set 10% to 15% above maximum differential pressure (Viking Pump, n.d.). Viking’s figure marks the start of opening; HI’s 10% to 25% is the further rise to fully open (Hydraulic Institute, n.d.).

    Viking names three valve types: internal, which returns liquid to the pump inlet and can heat it in long full bypass; return-to-tank, which carries heat away; and inline, in the system piping (Hall, n.d.), with no isolation valve between it and the pump (Hall, n.d.). Flammable liquids may need return-to-tank valves, since a deadheaded pump (one running against a closed discharge) on internal relief could heat them past their flash point (Hall, n.d.). DOE notes that relief valves, internal in many positive displacement pumps (U.S. Department of Energy & Hydraulic Institute, 2006), need periodic testing and maintenance (U.S. Department of Energy & Hydraulic Institute, 2006).

    Viking also notes an exception: most air-operated double diaphragm (AODD) pumps can be deadheaded without overpressure protection, because maximum discharge pressure cannot exceed the air inlet pressure, usually 100 psi (7 bar) or less (Hall, n.d.). Shinjo lists a 0.3 to 0.7 MPa (44 to 102 psi) air supply for its QBY and QBK air-operated diaphragm pumps. Check the data sheet before deadheading a given pump.

    Speed, stroke and bypass

    Flow from a PD pump is directly proportional to speed (U.S. Department of Energy & Hydraulic Institute, 2006), so a variable frequency drive (VFD) changes flow by changing speed. HI notes that the torque load stays constant as speed falls, unlike on a rotodynamic pump (Hydraulic Institute, n.d.), and that start-up can demand maximum pressure and torque (Hydraulic Institute, n.d.); select the drive for both. On metering pumps, stroke length also sets flow, linearly but not necessarily in proportion, per HI (Hydraulic Institute, n.d.). A bypass back to suction recirculates liquid the way an internal relief valve does, the case in which Viking warns of heating (Hall, n.d.). A control bypass therefore needs its own valve; the relief valve stays reserved for upsets (Hall, n.d.).

    Suction: NPIP, acceleration head and pulsation

    Suction on a positive displacement pump is often specified in net positive inlet pressure (NPIP), which Viking Pump defines as “the absolute pressure required at the inlet of the pump to prevent cavitation” and likens to net positive suction head (NPSH) (Viking Pump, n.d.). NPIPA is what the system supplies; NPIPR is what the pump requires (Viking Pump, n.d.). Blacoh notes that these terms “reflect the use of pressure units rather than feet” (Cornell, n.d.).

    Illustration of a triplex plunger pump with a suction stabilizer and a discharge pulsation dampener, fed by a short straight suction pipe
    A triplex plunger pump with a dampener on each side and a short, straight suction pipe, a layout that keeps acceleration head low. The relief valve sits ahead of any other discharge valve.

    The Hydraulic Institute (HI) states that viscosity raises the NPIPR of PD pumps (Gaydon, 2022). A reciprocating PD pump also loses inlet pressure to acceleration head (Henshaw, n.d.), because it draws in pulses and the suction flow speeds up and slows down with each stroke. Peak flow from a piston or diaphragm pump “can be as much as 3.14 times the average or mean flow,” per Blacoh (Cornell, n.d.); HI’s metering-pump guidance says peaks can reach three times the average (Hydraulic Institute, n.d.). For short metering-pump runs, HI’s rule of thumb is suction piping one size above the discharge piping, or two sizes above the pump suction connection (Hydraulic Institute, n.d.).

    Animated triplex plunger pump: one cylinder's plunger, suction valve and discharge valve, three cranks 120 degrees apart, and a chart of discharge flow ripple
    One crank revolution of a triplex plunger pump. A single cylinder’s flow peaks at about 3.14 times its mean; three plungers 120° apart cut the ripple to about +5% / −9% (idealized), and dampeners smooth it further.

    The acceleration-head equation in HI standards uses US units: ha = (L × V × N × C) / (k × g) (Cornell, n.d.; Henshaw, n.d.). Here ha is in ft, L is the actual (not equivalent) suction length in ft, V the average suction velocity in ft/s, N the crankshaft speed in rpm and g = 32.2 ft/s² (Henshaw, n.d.). C is 0.400 for a single-acting simplex, 0.066 for a triplex and 0.022 for a nonuplex; k is 1.5 for most liquids (Henshaw, n.d.). A properly selected dampener cuts the effective L to about 10 pipe diameters (Henshaw, n.d.). The equation is recommended only for relatively short, non-elastic suction lines (Henshaw, n.d.).

    Using the HI equation, a triplex plunger pump on a 3.05 m (10 ft) suction line at 0.457 m/s (1.5 ft/s) and 300 rpm loses 1.87 m (6.15 ft) to acceleration head, or 0.18 bar (2.7 psi) for water at specific gravity 1.0. With a suction dampener on a DN50 (NPS 2) line, that drops to 0.31 m (1.0 ft).

    Before comparing NPIPA with NPIPR on a reciprocating PD pump, subtract the acceleration head. The equation is written for the pulsing suction flow of a reciprocating pump (Henshaw, n.d.). On a rotary positive displacement pump, check NPIPR at the duty viscosity, since viscosity raises it (Gaydon, 2022).

    By the Numbers

    • 3.14x peak-to-mean flow ratio a piston or diaphragm pump can reach, per Blacoh (Cornell, n.d.)
    • ~10 diameters effective suction length with a properly selected dampener, per HI (Henshaw, n.d.)
    • 1.87 m acceleration head in the triplex worked example above, calculated with the HI equation, no dampener
    • 0.31 m the same triplex with a dampener on a DN50 line

    Centrifugal vs positive displacement pump: how to choose

    The search “centrifugal positive displacement pump” asks for a comparison, and the answer turns on viscosity, pressure and flow control. The US Department of Energy sourcebook says centrifugal pumps are more common because they are simple and safe, need minimal maintenance and suffer less wear (U.S. Department of Energy & Hydraulic Institute, 2006). The same sourcebook points to a positive displacement pump for high pressure at low flow, high viscosity, accurately controlled flow, self-priming and low-shear duties, and wherever pump efficiency is highly valued (U.S. Department of Energy & Hydraulic Institute, 2006).

    Viscosity separates the two families first. The Hydraulic Institute (HI) PD pump members report that frictional losses degrade centrifugal flow and efficiency with fluids above 500 SSU (Saybolt seconds universal) (Hydraulic Institute PD Pump Members, 2011), while rotary PD flow and efficiency typically increase with viscosity (Hydraulic Institute PD Pump Members, 2011). A 2025 review of the literature reports centrifugal head losses of 8 m (26 ft) or more and an efficiency reduction of 20% as viscosity approaches 800 to 1,000 cP (Ifidon et al., 2025). HI bases its ANSI/HI 9.6.7 correction factors on empirical data up to 3,000 cSt, usable to 4,000 cSt with increased uncertainty, and notes they do not apply to PD pumps (Hydraulic Institute, n.d.). Shinjo’s guide on how to select a centrifugal pump sets out that correction method.

    Small flows at high pressure also favor a positive displacement pump. HI’s PD pump members write that PD technology “easily handles flows below 100 gpm and pressures greater than 200 psi” (Hydraulic Institute PD Pump Members, 2011), roughly 22.7 m3/h and 13.8 bar. PD pumps handle a high percentage of entrained air or gas (Hydraulic Institute PD Pump Members, 2011; U.S. Department of Energy & Hydraulic Institute, 2006) and are self-priming with excellent suction lift (Hydraulic Institute PD Pump Members, 2011). Because they are constant-torque devices, a variable frequency drive (VFD) on one must be rated for that load (Hydraulic Institute PD Pump Members, 2011).

    To tell the two apart, look at parts and curves. A rotary PD pump has meshing gears, lobes, screws or vanes and no impeller (Hydraulic Institute, 2024). On a data sheet, PD flow stays nearly flat as pressure rises, while centrifugal flow falls as head rises (Hall, n.d.; Hydraulic Institute PD Pump Members, 2011). Never test by closing the discharge valve.

    Factor Centrifugal Positive displacement
    Flow vs pressure Flow falls as head rises (Hall, n.d.; Hydraulic Institute PD Pump Members, 2011) Flow stays nearly flat at constant speed (Hall, n.d.; Hydraulic Institute PD Pump Members, 2011)
    Viscosity Flow and efficiency degrade above 500 SSU (Hydraulic Institute PD Pump Members, 2011) Rotary types: flow and efficiency typically rise with viscosity (Hydraulic Institute PD Pump Members, 2011)
    Efficiency on viscous fluids Near 80% on water, about 50% at 1,000 SSU (SG 0.9), in HI’s worked example (Gaydon, 2022) Often 10 to 40 points higher, for viscous fluids that both can handle (Hydraulic Institute PD Pump Members, 2011)
    Entrained gas Depends on the design; check the data sheet Handles a high percentage of air or gas (Hydraulic Institute PD Pump Members, 2011; U.S. Department of Energy & Hydraulic Institute, 2006)
    Priming and suction lift Often needs equipment to remove gas and prime the impeller; some designs are self-priming (U.S. Department of Energy & Hydraulic Institute, 2006) Self-priming, with excellent suction lift (Hydraulic Institute PD Pump Members, 2011)
    Flow control Valve or speed; a variable-torque load on a VFD (Hydraulic Institute, n.d.) Speed, through a VFD rated for constant torque (Hydraulic Institute PD Pump Members, 2011)
    Overpressure protection May not need it (Hall, n.d.) Needed, usually a relief valve (U.S. Department of Energy & Hydraulic Institute, 2006); most AODD pumps aside (Hall, n.d.)
    Best-fit duty Thin liquids at higher flow; simple, safe, low wear (U.S. Department of Energy & Hydraulic Institute, 2006) Viscous, high-pressure low-flow, metering and low-shear duties (U.S. Department of Energy & Hydraulic Institute, 2006)

    For viscous fluids that both pump types can handle, the Hydraulic Institute’s PD pump members say the positive displacement option often can be 10 to 40 points more energy-efficient than the centrifugal pump (Hydraulic Institute PD Pump Members, 2011). In HI’s worked example, one centrifugal pump fell from near 80% efficiency on water to approximately 50% on 1,000 SSU (Gaydon, 2022).

    HI frames that advantage around viscous fluids, so it gives no efficiency reason to prefer PD on water. The example liquid, roughly 216 cSt, sits well inside the ANSI/HI 9.6.7 data range, so the loss of about 30 points came at a moderate viscosity. For thin liquids at higher flow, start with a centrifugal pump. For viscous duties, correct its curve and compare a PD pump at the same duty point, relief protection and wear parts included.

    Downsides and dry running of positive displacement pumps

    The fixed displacement that makes a PD pump predictable also makes it demanding to protect. The US Department of Energy pumping sourcebook says PD pumps “typically require more system safeguards, such as relief valves” (U.S. Department of Energy & Hydraulic Institute, 2006). The Hydraulic Institute adds that they require some type of pressure protection and that certain designs require pulsation control (Hydraulic Institute PD Pump Members, 2011). Some units also carry duty-cycle limits (Hydraulic Institute PD Pump Members, 2011).

    Illustration of a progressing cavity pump on sludge duty, with a temperature sensor on the stator and a sample point on the discharge
    A progressing cavity pump on sludge duty, with a temperature sensor on the stator wired to a relay that stops the pump if it starts to run dry.

    Wear is the second trade-off, and the same sourcebook lists the mechanisms. Cyclical action “causes fatigue in components such as bearings and diaphragms” (U.S. Department of Energy & Hydraulic Institute, 2006). Pulsating flow creates vibration that hastens degradation of piping, valves and supports, especially when pulse rate harmonics coincide with a natural frequency (U.S. Department of Energy & Hydraulic Institute, 2006); accumulators can dampen it (U.S. Department of Energy & Hydraulic Institute, 2006). PD pumps “are very susceptible to wear from abrasives” (U.S. Department of Energy & Hydraulic Institute, 2006). For rotary pumps, the Hydraulic Institute says close running clearances make clean piping a must: dirt, grit, weld bead or scale “will damage and may seize the pump” (Hydraulic Institute, n.d.). A relatively high number of moving parts means larger spare-parts inventories (U.S. Department of Energy & Hydraulic Institute, 2006) and, in the sourcebook’s words, “higher maintenance requirements than other types” (U.S. Department of Energy & Hydraulic Institute, 2006).

    Whether a positive displacement pump can run dry depends on its type.

    Progressing cavity pumps are one of the types at risk. A 2024 NETZSCH article says these pumps “can be sensitive to dry running if not sufficiently lubricated, leading to increased wear” (NETZSCH Pumps & Systems, 2024).

    Animated progressing cavity pump: the cavities empty, friction heats the stator, and a temperature sensor in the stator rubber trips the motor
    Dry-run protection on a progressing cavity pump: when the liquid runs out, friction heats the stator, and a temperature sensor in the stator rubber trips the motor before the rubber is damaged.

    Penn Valley Pump, a vendor of double disc pumps, lists gear, rotary lobe and piston or plunger pumps among the types not to run dry, and says “most positive displacement pumps can only run dry for a few minutes before friction heats up the internals”.

    An air-operated double diaphragm pump tolerates dry running, but Yamada treats that ability as protection against an upset, not an operating strategy: a pump running dry cycles faster, adding diaphragm wear and wasting compressed air (Eklund, 2026). Diaphragm does not mean dry-run tolerant, though: Shinjo states that its DBY electric diaphragm pump “is strictly forbidden to run dry”. NETZSCH’s glossary entry on dry running says some displacement pumps, such as peristaltic pumps, can tolerate dry running without damage, while others need dry-running sensors or automatic shutdowns. Confirm the rating on the model’s data sheet, and where a suction tank can empty, specify dry-run protection.

    Specifying a positive displacement pump

    A usable inquiry for a positive displacement pump states the liquid, duty, suction and protection, with units and operating conditions. Give viscosity at the coldest condition: the Hydraulic Institute bases rotary pump pipe size on the required flow, velocity limits, “the fluid viscosity at the lowest pumping temperature”, piping length and pump elevation (Hydraulic Institute, n.d.).

    Item What to state Why it matters
    Liquid Name, specific gravity, viscosity range Viscosity shifts slip and input power (Gaydon, 2022)
    Duty Flow at the duty, differential pressure, maximum discharge pressure Sets size, speed, power and relief setting
    Suction NPIPa, or suction layout and line length Checked against the pump’s NPIPr
    Solids and shear Particle size, concentration, abrasiveness, shear sensitivity Higher speed adds abrasive wear and shear (Blodgett, n.d.)
    Temperature and materials Operating range; wetted metals and elastomers Compatibility changes with liquid and temperature
    Seal Packing, mechanical seal or sealless Must suit liquid, pressure and temperature
    Drive Motor, speed range, VFD A positive displacement pump is a constant-torque load; rate the VFD for it (Hydraulic Institute PD Pump Members, 2011)
    Relief Internal, return-to-tank or inline; set pressure Internal relief recirculates to the inlet and can heat the liquid (Hall, n.d.)
    Pulsation Dampener needed, and who supplies it Pulsation vibration wears piping, valves and supports (U.S. Department of Energy & Hydraulic Institute, 2006)
    Tests and data sheet ANSI/HI 3.6 rotary or HI 6.6 reciprocating test; the API data sheet where API applies (API 675 carries them in its Annex A) (Ray, n.d.) Fixes how performance is proven

    For pressure, request five values as Viking Pump defines them: maximum differential pressure, maximum allowable working pressure, maximum allowable inlet pressure, cracking pressure and full bypass pressure (Viking Pump, n.d.). A request for Shinjo’s single-screw progressing cavity pumps needs the same data.

    API 675 sets steady-state accuracy, linearity and repeatability criteria for controlled-volume metering pumps (Ray, n.d.), and its Annex A data sheets come in USC and SI units (Ray, n.d.). Wanner, for example, states its metering pumps exceed ±1% steady-state accuracy, ±3% linearity and ±3% repeatability, so a metering inquiry should name the standard.

    Frequently Asked Questions

    Can you run a PD pump dry?

    It depends on the type. Progressing cavity pumps should not; NETZSCH notes they can be sensitive to dry running, which increases wear (NETZSCH Pumps & Systems, 2024). Penn Valley Pump lists piston, plunger, gear and lobe pumps among the types not to run dry either. Air-operated double diaphragm pumps tolerate it, though a pump running dry cycles faster, adding diaphragm wear and wasting compressed air (Eklund, 2026).

    Is a screw pump a PD pump?

    Yes. The Hydraulic Institute lists screw pumps among rotary positive displacement designs, which move liquid with meshing components such as screws, gears, lobes and vanes (Hydraulic Institute, 2024). Its table names single-screw (progressing cavity), two-screw (timed) and three-screw (untimed) pumps (Hydraulic Institute, 2024).

    Is a gear pump a PD pump?

    Yes, a rotary one. The Hydraulic Institute’s Data Tool lists external gear pumps and internal gear pumps, with or without a crescent, among rotary types (Hydraulic Institute, 2024). Their displacement is fixed, so flow follows shaft speed (U.S. Department of Energy & Hydraulic Institute, 2006), less internal leakage called slip (Gaydon, 2022).

    What are the three types of positive displacement pumps?

    Hydraulic Institute members name three major categories: reciprocating, rotary and controlled-volume metering pumps (Hydraulic Institute PD Pump Members, 2011). Metering pumps are reciprocating designs configured to dispense an accurate volume in a set time (Hydraulic Institute PD Pump Members, 2011). The Institute’s Data Tool divides the class into just two, reciprocating and rotary, so sources group them differently (Hydraulic Institute, 2024).

    What is the difference between positive and non-positive displacement pumps?

    A PD pump traps a volume of liquid and moves it with each shaft rotation (Hydraulic Institute, 2024), without relying on a velocity change (Hydraulic Institute PD Pump Members, 2011). The non-positive kind is the rotodynamic pump, such as a centrifugal pump, which imparts energy to the liquid with a rotating impeller (Hydraulic Institute, 2024).

    How to tell if a pump is centrifugal or positive displacement?

    A centrifugal pump spins an impeller; a positive displacement design uses pistons, plungers, diaphragms or meshing parts such as gears and screws (Hydraulic Institute, 2024). At constant speed, PD flow stays nearly flat as head rises, while centrifugal flow falls (Hydraulic Institute PD Pump Members, 2011). Never test by closing the discharge: a PD pump keeps building pressure (U.S. Department of Energy & Hydraulic Institute, 2006).

    Why is it called a positive displacement pump?

    The name describes the mechanism. The pump encloses a volume of liquid and positively forces it out by shrinking the space that contains it (U.S. Department of Energy & Hydraulic Institute, 2006). The US Department of Energy calls this a collapsing volume action, squeezing out the displacement volume with each piston stroke or shaft rotation (U.S. Department of Energy & Hydraulic Institute, 2006).

    Why use a VFD on a pump?

    On a positive displacement pump, flow is typically varied by speed, which a variable frequency drive (VFD) controls (Hydraulic Institute PD Pump Members, 2011; U.S. Department of Energy & Hydraulic Institute, 2006); throttling the discharge raises pressure rather than cutting flow (U.S. Department of Energy & Hydraulic Institute, 2006). Rate the drive for a constant-torque load: a PD pump keeps that load as speed falls, unlike a rotodynamic pump (Hydraulic Institute, n.d.).

    Conclusion

    A positive displacement pump moves a fixed volume with every stroke or revolution, less the slip that leaks back inside it. Flow follows speed. Pressure follows the system.

    Close a valve on the discharge and the pressure climbs until something gives. A motor-driven PD pump therefore needs overpressure protection, usually a relief valve, and flow is set by speed, stroke or bypass, never by throttling the discharge. Suction is checked as net positive inlet pressure (NPIP), plus acceleration head on a reciprocating pump. Against a centrifugal pump, choose PD for viscous liquids, high pressure at low flow, metered doses and liquids with entrained gas.

    That logic also sets what to check on paper. A datasheet should state displacement per revolution, the speed range, volumetric efficiency at your viscosity and differential pressure, required NPIP, and the relief valve type and setting. A quote should answer the duty you sent: viscosity at the lowest pumping temperature, maximum discharge pressure, duty cycle, wetted materials and a drive rated for constant torque. Send any blank line back as a question before ordering.

    References

    1. Hydraulic Institute. (2024, April 19). Pump types. HI Data Tool. https://datatool.pumps.org/introduction-definitions-references/pump-types
    2. U.S. Department of Energy, & Hydraulic Institute. (2006). Improving pumping system performance: A sourcebook for industry (2nd ed.). U.S. Department of Energy. https://www.energy.gov/sites/prod/files/2014/05/f16/pump.pdf
    3. Hydraulic Institute PD Pump Members. (2011, June 9). Fundamentals of positive displacement pumps. Plant Services. https://www.plantservices.com/equipment/fluid-handling/article/11334594/pump-performance-fundamentals-of-positive-displacement-pumps-the-hydraulic-institute-provides-an-overview-of-positive-displacement-pumps-performance-characteristics-plant-services
    4. Gaydon, P. (2022, December 7). How viscosity affects pumping. Hydraulic Institute. https://www.pumps.org/2022/12/07/how-viscosity-affects-pumping
    5. Hydraulic Institute. (n.d.). Pump FAQs. Retrieved October 15, 2026, from https://www.pumps.org/resources/pump-faqs
    6. Blodgett, B. (n.d.). The volumetric efficiency of rotary positive displacement pumps. Pumps & Systems. https://www.pumpsandsystems.com/article/volumetric-efficiency-rotary-positive-displacement-pumps
    7. Gannon, M. (n.d.). What is the difference between fixed and variable pumps? Mobile Hydraulic Tips. https://www.mobilehydraulictips.com/what-is-the-difference-between-fixed-and-variable-pumps
    8. Hall, J. (n.d.). Pressure relief valves: Critical to pump and system safety and reliability. Viking Pump. https://www.vikingpump.com/blog/pressure-relief-valves
    9. Viking Pump. (n.d.). Frequently asked questions. Retrieved October 15, 2026, from https://www.vikingpump.com/faq
    10. Cornell, G. L. (n.d.). Solving pump inlet problems. BLACOH Fluid Control. https://www.blacoh.com/downloads/literature/Solving_Pump_Inlet_Problems_P21E11_010.pdf
    11. Henshaw, T. (n.d.). Acceleration head. Pumps & Systems. https://www.pumpsandsystems.com/article/acceleration-head
    12. Ray, R. (n.d.). API Standard 675 for positive displacement pumps. Pumps & Systems. https://www.pumpsandsystems.com/article/api-standard-675-positive-displacement-pumps
    13. Ifidon, O., Pandey, D. S., Ahmad, K., Jaworski, A. J., & Asfand, F. (2025). A review of industrial pumps for viscous and non-Newtonian slurry transport. International Journal of Thermofluids, 30, Article 101450. https://doi.org/10.1016/j.ijft.2025.101450
    14. NETZSCH Pumps & Systems. (2024, March 26). What you need to know about progressing cavity pumps. https://pumps-systems.netzsch.com/en-US/news/2024/what-you-need-to-know-about-progressing-cavity-pumps
    15. Eklund, R. (2026, September 1). Can an AODD pump run dry? Understanding the costs of dry running. Yamada Pump. https://www.yamadapump.com/blog/can-an-aodd-pump-run-dry-understanding-the-costs-of-dry-running

    Last reviewed and updated: November 2026. Author: Shinjo Pump engineering team. For pump selection support or a quotation on your duty point, contact our team.




  • Sewage Pump: Types, Lift Stations, Sizing and Controls

    Sewage Pump: Types, Lift Stations, Sizing and Controls

    Sewage Pump: Types, Lift Stations, Sizing and Controls

    • Oct 27, 2026
    • Hits: 16

    On this page

    Abstract

    A sewage pump moves raw wastewater that carries solids and fibers. Its defining specification is solids passage: the largest sphere it can pass. In buildings, the 2025 Plumbing Code of New York State (section 712.4.2), based on the International Plumbing Code, requires a non-grinder pump that receives toilet discharge to handle spherical solids up to 2 in (51 mm) (International Code Council & New York State Department of State, 2025). In municipal stations, the 2014 edition of the Recommended Standards for Wastewater Facilities (Ten States Standards, section 42.33) asks pumps handling raw wastewater to pass solid spheres of at least 80 mm (3 in) (Great Lakes-Upper Mississippi River Board, 2014). Flow and head decide the duty point; solids passage decides whether the pump keeps running.

    Sewage pump lift station wet well from above: two submersible pumps on guide rails with chains, risers and float switches
    A lift station wet well from above

    This guide is for procurement, project and utility engineers who specify or buy pumps and pump stations. It sets out the pump types and where each fits, the parts and controls of a sewage pump system, and a worked sizing example. It also explains pressure sewers, seals and motor protection, failure causes, and what a quote request must state. Homeowners get a short answer and a clear line where residential practice ends.

    Key Takeaways

    • Solids passage defines the pump: 51 mm (2 in) for toilet discharge; 80 mm (3 in) in Ten States 2014.
    • Size for firm capacity: with any pump out of service, the remaining pumps carry design peak hourly flow.
    • Keep force-main velocity in range: at design pumping rates, 0.6 m/s minimum and 2.4 m/s recommended maximum (2-8 ft/s).
    • Illustrative worked example: 31.4 L/s (498 gpm) at 28.1 m (92 ft) TDH through 600 m of DN150 force main.
    • Wet-well volume: V = T x Q / 4, where cycle time T comes from the pump maker’s starts-per-hour limit.
    • Pressure sewers fit where gravity costs too much: low housing density, flat ground with high groundwater or bedrock, uphill outfalls.
    • Wipes clog sewage pumps: NACWA estimates they add about $441 million a year to US collection-system operating costs (2019 data).

    Table of Contents

    What a sewage pump is and the solids it must pass

    A sewage pump, in KSB’s definition, transports sewage and untreated wastewater, mainly in municipal treatment plants but also in buildings and private homes that cannot drain to the sewer by gravity (KSB, n.d.). Some shopping listings call the same machine a sewage water pump.

    Sewage, effluent, sump and grinder pumps

    SSPMA trade classes, as Goulds/Xylem presents them, sort these pumps by solids size. Sump pumps handle clear water with solids up to 1/2 in (Rook, n.d.). Effluent pumps handle solids up to 1 in, in partly or fully treated wastewater leaving a septic tank or treatment plant (Rook, n.d.). Sewage pumps start at 1-1/2 in, with the note that most codes say 2 in, and handle household wastewater that may contain human waste (Rook, n.d.).

    Effluent and sewage duties differ. In a septic tank, solids settle as sludge and the liquid effluent flows on to the drainfield (U.S. Environmental Protection Agency, 2026). An effluent pump moves that settled liquid; an ejector takes raw sewage straight from the toilet. A grinder pump cuts solids for high-head discharge through small pipe (Rook, n.d.).

    Solids passage: the defining specification

    The 2025 Plumbing Code of New York State, built on the International Plumbing Code, states solids passage as a sphere: 13 mm (1/2 in) for other pumps or ejectors (International Code Council & New York State Department of State, 2025), and more once a toilet discharges to the pump.

    Pump or duty Solids it must pass Source
    Sump pump, clear water Up to 1/2 in SSPMA class (Rook, n.d.)
    Effluent pump, settled effluent Up to 1 in SSPMA class (Rook, n.d.)
    Sewage pump or ejector receiving toilet discharge Spheres up to and including 51 mm (2 in) 2025 NY Plumbing Code, §712.4.2 (International Code Council & New York State Department of State, 2025)
    Building lifting plant, fecal wastewater Free passage of at least 40 mm EN 12050-1, as DAB Pumps summarizes it
    Raw-wastewater pumping station Spheres of at least 80 mm (3 in); openings at least 100 mm (4 in) 2014 edition of the Ten States Standards, §42.33 (Great Lakes-Upper Mississippi River Board, 2014)
    Grinder pump or ejector receiving toilet discharge Exempt from the sphere rule; discharge opening at least 32 mm (1-1/4 in) 2025 NY Plumbing Code, §712.4.2 exception (International Code Council & New York State Department of State, 2025)

    Goulds/Xylem draws the residential line at 2 in solids; typical municipal and commercial stations pass 3 in or more (Rook, n.d.). The 2014 edition of the Ten States Standards allows case-by-case exceptions to section 42.33 where the design gives equivalent protection from clogging, and it names grinder pumps as an example (Great Lakes-Upper Mississippi River Board, 2014). The Minnesota Department of Health now lists a 2026 edition of the Recommended Standards for Wastewater Facilities (Ten States Standards) as current and the 2014 edition as archived. Check the edition your state adopts.

    Section 712.4.2 of the 2025 Plumbing Code of New York State requires a sewage pump or ejector receiving toilet discharge to handle spheres up to and including 51 mm (2 in) (International Code Council & New York State Department of State, 2025). For pumps handling raw wastewater, section 42.33 of the 2014 edition of the Ten States Standards sets a minimum sphere diameter of 80 mm (3 in) (Great Lakes-Upper Mississippi River Board, 2014).

    Types of sewage pump and where each fits

    The US EPA’s 2000 lift-station fact sheet, EPA 832-F-00-073, names dry-well and submersible as the two most common lift-station types (U.S. Environmental Protection Agency, 2000). Submersible pumps are lifted out and reinstalled on guide rails with a hoist (U.S. Environmental Protection Agency, 2000). Dry-well stations allow easy inspection and are generally easier to repair (U.S. Environmental Protection Agency, 2000), while submersible stations typically cost less and run without frequent pump maintenance (U.S. Environmental Protection Agency, 2000).

    Type Where it sits Where it fits What to watch
    Submersible on guide rail Wet-well floor, under the liquid Permanent stations; typically lower cost (U.S. Environmental Protection Agency, 2000) Surface-cooled motors must stay submerged
    Dry-pit Dry room next to the sump Inspection and repair access (U.S. Environmental Protection Agency, 2000) Motor cooling (a jacket)
    Vertical (column) submersible Upright in the sump Within its listed temperature and density limits Seal design
    Self-priming, above ground Above the liquid Shallow pits; the pump stays dry Suction lift (2014 Ten States, section 43.11) (Great Lakes-Upper Mississippi River Board, 2014)
    Sewage transfer pump Portable, at the job Tank-to-tank transfer, tanker unloading, station bypass Solids size and priming lift
    Submersible sewage pump beside its duck-foot discharge bend, and a dry-pit pump coupled to a motor on a baseplate
    Two installation types: a submersible pump with its discharge connection, and a dry-pit pump driven by a motor on a shared baseplate.

    Submersible sewage pump

    Wilo describes the submersible wastewater pump, the trade’s other name for a submersible sewage pump, as close-coupled with a sealed motor. A surface-cooled motor sheds heat into the surrounding liquid, which works as long as the pump stays fully submerged; jacket-cooled designs keep cooling at low levels or in dry conditions. Shinjo rates its WQ series for liquids from 0 to 55 °C (32 to 131 °F).

    Dry-pit, vertical and self-priming sewage pumps

    As Grundfos explains, a dry-pit pump sits beside the sump, and its motor needs cooling from a jacket carrying an external liquid or the pumped liquid. Grundfos describes a trend toward dry installation, mainly because of the working environment for servicing the pumps. EPA’s 2000 fact sheet described the opposite trend for small and medium stations (typically below 24,000 L/min, or 6,350 gpm): replacing dry-well stations with submersible ones, mainly because of lower cost, a smaller footprint and simpler operation and maintenance (U.S. Environmental Protection Agency, 2000). Both can hold: submersible stations save cost and space, while a dry pit gives crews a better place to service the pumps.

    Shinjo lists its YW vertical submersible sewage pump for 0 to 80 °C (32 to 176 °F), a wider window than the WQ’s, and specific gravity up to 1.5, with a double mechanical seal.

    The 2014 edition of the Ten States Standards required suction-lift pumps to be self-priming or vacuum-priming (section 43.1) (Great Lakes-Upper Mississippi River Board, 2014). Section 43.11 limited self-priming suction piping to 7.6 m (25 ft) in length (Great Lakes-Upper Mississippi River Board, 2014) and capped dynamic suction lift at pump-off plus the required net positive suction head (NPSHR) at 6.7 m (22 ft) (Great Lakes-Upper Mississippi River Board, 2014). Shinjo’s ZW self-priming non-clogging sewage pump needs no foot valve and is rated to 80 °C (176 °F); it comes in cast iron or stainless steel.

    For a given pit, Shinjo’s self-priming vs submersible sewage pump guide works through the choice, starting from suction lift. The impeller is a separate choice: KSB’s pump lexicon names single-vane and channel impellers alongside free-flow (torque-flow) and diagonal designs (KSB, n.d.), and Shinjo’s non-clogging pump guide sets out their trade-offs.

    Sewage transfer pump

    The trade gives the name sewage transfer pump to portable self-priming trash, shredder or dry-priming pumps on temporary jobs such as tanker unloading or station bypass. Xylem states that its Godwin Dri-Prime range moves raw sewage with solids up to 125 mm (4.9 in) and primes automatically from dry to 8.5 m (28 ft) of suction lift; the pumps can also run dry. That is one range’s priming capability, separate from the 6.7 m (22 ft) limit section 43.11 set for permanent stations (Great Lakes-Upper Mississippi River Board, 2014). The 2014 text also listed portable pumping equipment as one way to provide emergency pumping (section 47.2) (Great Lakes-Upper Mississippi River Board, 2014).

    The sewage pump system inside a lift station

    A lift station is a sewage pump system at municipal scale: inflow collects in a wet well, pumps lift it, valves stop backflow and a force main carries it away. US EPA’s 2000 fact sheet puts lift-station capacities at 76 L/min (20 gpm) to more than 378,500 L/min (100,000 gpm) (U.S. Environmental Protection Agency, 2000). Centrifugal pumps are commonly used (U.S. Environmental Protection Agency, 2000).

    Duplex lift station valve chamber: each discharge line has a gauge, swing check valve and gate valve before the force main
    In the valve chamber each pump’s line passes a check valve, then a gate valve, before the two lines join the force main.

    Wet well, guide rails and valves

    Per EPA, a wet well must be large enough to prevent rapid pump cycling and small enough to prevent long detention and odor release (U.S. Environmental Protection Agency, 2000).

    Typical maximum detention is 20 to 30 minutes with constant-speed pumps and 5 to 15 minutes with variable-frequency drives (U.S. Environmental Protection Agency, 2000).

    Submersible sewage pumps are periodically lifted to the surface and reinstalled on guide rails with a hoist (U.S. Environmental Protection Agency, 2000). The 2014 edition of the Ten States Standards (section 42.31) calls for multiple pumps, equal in size where only two are installed, so that with any unit out of service the rest still handle the design peak hourly flow (Great Lakes-Upper Mississippi River Board, 2014). That clause underlies firm capacity, a term the 2014 text does not use (Great Lakes-Upper Mississippi River Board, 2014).

    Under section 42.52, each sewage pump (screw pumps excepted) discharges through a shutoff valve and a check valve, the check valve nearer the pump (Great Lakes-Upper Mississippi River Board, 2014). The same section puts check valves on horizontal discharge piping, though ball checks may sit in the vertical run (Great Lakes-Upper Mississippi River Board, 2014). The pump lines then join the force main.

    Controls, alarms and variable speed

    EPA lists bubblers, electrodes, floats and mercury switches as level controls, with variable-speed drives for more sophisticated control (U.S. Environmental Protection Agency, 2000). The 2014 Ten States text (section 42.4) places level sensors away from turbulent inflow and pump suction (Great Lakes-Upper Mississippi River Board, 2014). It also asks for dual air compressors on bubbler systems and automatic alternation of the sewage pumps (Great Lakes-Upper Mississippi River Board, 2014).

    Section 46 (2014 edition) calls for alarms with a backup power source, activated by power failure, high water in the wet well or dry-well sump, pump failure, unauthorized entry or other malfunction (Great Lakes-Upper Mississippi River Board, 2014). Section 47.2 requires emergency pumping unless storage prevents overflow, using two independent utility substations, an engine generator, an engine pump or portable pumping equipment (Great Lakes-Upper Mississippi River Board, 2014).

    EPA notes that variable-speed pumps can work with a smaller wet well and hold a near-constant level with fewer starts and stops (U.S. Environmental Protection Agency, 2000). Energy savings can be significant where friction losses are large, yet the drive may not justify its added capital cost unless power is expensive (U.S. Environmental Protection Agency, 2000).

    A 2026 systematic review of 29 peer-reviewed studies on optimizing the operation of sewage pumping stations reports energy reductions of about 3-4% from minor control refinements and about 15-32% in studies using predictive scheduling or optimization (Guimarães et al., 2026). The review finds variable frequency drives widen the control options but yield no benefit without a control policy; most results come from simulations or short pilots (Guimarães et al., 2026).

    Ventilation, odor and hazardous areas

    Section 42.75 of the 2014 edition calls for mechanical wet-well ventilation with 100% fresh air: at least 12 air changes per hour if continuous, or 30 if intermittent (Great Lakes-Upper Mississippi River Board, 2014). Section 42.35 puts electrical equipment in raw-wastewater wet wells under National Electrical Code Class I, Division 1, Group D (Great Lakes-Upper Mississippi River Board, 2014). NFPA 820, whose current edition is 2024, sets requirements for protection against fire and explosion hazards in wastewater treatment and collection facilities, and EPA’s 2000 fact sheet cites it for fitting continuous ventilation systems with flow detection devices connected to alarms (U.S. Environmental Protection Agency, 2000).

    EPA calls minimizing wet-well turbulence a simple, widely used odor control; scrubbers or biofilters work better, as do chemicals added upstream (U.S. Environmental Protection Agency, 2000). EPA’s 1991 report to Congress traces hydrogen sulfide corrosion to acid attack, after biological conversion of the gas to sulfuric acid, and to direct attack on copper, iron, steel and electrical contacts.

    Ready when you are

    Solids passage first, then flow and head. When a project has its design flow, the total dynamic head at the low wet-well level and the largest sphere the pump must pass, put those figures in writing: the Sewage Pumps range is quoted against the duty point you state, which lets you check the offer against your own datasheet.

    By the Numbers

    • 12 per hour minimum continuous wet-well air changes, Ten States 2014 (Great Lakes-Upper Mississippi River Board, 2014)
    • 20 to 30 min typical maximum detention with constant-speed pumps, EPA 2000 (U.S. Environmental Protection Agency, 2000)
    • 5 to 15 min typical maximum detention with variable-frequency drives, EPA 2000 (U.S. Environmental Protection Agency, 2000)
    • 76 L/min (20 gpm), low end of EPA’s lift-station capacity range (U.S. Environmental Protection Agency, 2000)

    Sizing a sewage pump station: a worked example

    Sizing a duplex sewage pump station rests on peak hourly flow, total dynamic head at the low wet-well level, and active wet-well volume. Take 2,000 people at the 2014 Ten States per-capita design flow (Great Lakes-Upper Mississippi River Board, 2014). With an assumed 12.0 m lift through 600 m of DN150 force main, each pump then needs 31.4 L/s (498 gpm) at 28.1 m (92 ft).

    Every input here is an assumption chosen for illustration; the constants and formulas are sourced. Per-capita flow is 100 US gal (380 L) per day, the section 11.243 design value in the 2014 edition of the Ten States Standards (Great Lakes-Upper Mississippi River Board, 2014). The smooth or lined DN150 (6 in) main is taken as 0.150 m bore and 600 m (1,969 ft) long. Static head from pump stop to the discharge high point is 12.0 m (39.4 ft); minor losses total K = 5.0, and sewage is treated as water at 1,000 kg/m3.

    Design flow and the peaking factor

    Figure 1 of the 2014 edition, credited there to Fair and Geyer, 1954, gives the ratio of peak hourly to average flow (Great Lakes-Upper Mississippi River Board, 2014):

    PF = (18 + √P) / (4 + √P), with P the population in thousands.

    With P = 2.0, PF = 3.586. Average flow is 8.763 L/s (138.9 gpm); multiplied by PF, peak hourly flow is 31.4 L/s, or 113.1 m3/h (498 gpm).

    Two equal sewage pumps, each sized for 31.4 L/s, meet 2014 Ten States §42.31: with one out of service, the other carries peak hourly flow (Great Lakes-Upper Mississippi River Board, 2014). EPA’s 2000 lift-station fact sheet calls that layout customary below 2,640 L/min (700 gpm) of maximum inflow (U.S. Environmental Protection Agency, 2000), and 498 gpm qualifies.

    Total dynamic head in the force main

    Velocity is v = Q / A = 1.78 m/s (5.83 ft/s). That lies between the 0.6 m/s (2 ft/s) cleansing minimum and the 2.4 m/s (8 ft/s) recommended maximum of 2014 Ten States §49.1 (Great Lakes-Upper Mississippi River Board, 2014); DN150 also clears the clause’s 100 mm (4 in) minimum diameter for raw wastewater (Great Lakes-Upper Mississippi River Board, 2014).

    The 2014 edition’s §49.61 sets C = 100 for unlined iron or steel and allows a higher C, not exceeding 120, for smooth or lined pipe (Great Lakes-Upper Mississippi River Board, 2014). Friction follows the SI Hazen-Williams form:

    h_f = 10.67 x L x Q^1.852 / (C^1.852 x D^4.8704)

    At C = 120 that gives 15.32 m (50.3 ft); a US-unit cross-check agrees within 0.2%. Minor losses, K x v²/2g, are 5.0 x 0.161 = 0.81 m (2.6 ft). The components of pump total head then add up:

    TDH = static + friction + minor = 12.0 + 15.32 + 0.81 = 28.1 m (92 ft)

    That duty point sits at the low wet-well level; at the start level, static head is smaller and the pump runs further out on its curve. Only friction changes with C:

    Hazen-Williams C Friction loss TDH
    100 (unlined iron or steel) (Great Lakes-Upper Mississippi River Board, 2014) 21.47 m 34.3 m
    120 (design case) 15.32 m 28.1 m
    140 (new pipe) 11.52 m 24.3 m
    Bar chart of friction loss and total dynamic head at C = 100, 120 and 140, giving TDH of 34.3, 28.1 and 24.3 m
    Worked example at 31.4 L/s on illustrative inputs: TDH is 34.3 m at C = 100 and 24.3 m at C = 140, because only friction changes.

    A new, smoother main has a higher C and lowers the system curve: the pump delivers more flow and draws more power. Under 2014 Ten States §49.62, designers consider that effect on maximum power and duty-cycle time to prevent motor damage (Great Lakes-Upper Mississippi River Board, 2014).

    At 1,000 kg/m3, hydraulic power P = ρ x g x Q x H is 8.67 kW (11.6 hp); at an assumed 60% pump efficiency, shaft power is 14.4 kW (19.4 hp). That is arithmetic only; the motor follows the pump supplier’s curve and service factor.

    Wet-well volume and starts per hour

    Flygt’s design brochure gives the minimum active (start-to-stop) volume as V = T x Q / 4, with T the minimum cycle time and Q the pump rate. The brochure states that Flygt pumps can make 15 starts per hour without endangering pump life. The 2014 edition’s §42.62 sets minimum cycle time from the pump maker’s duty-cycle recommendation (Great Lakes-Upper Mississippi River Board, 2014) and caps fill time at 30 minutes at design average flow (Great Lakes-Upper Mississippi River Board, 2014).

    Required volume and fill time at average flow:

    • 15 starts per hour (T = 4 min): 1.885 m3 (498 US gal), 3.6 min fill
    • 10 starts per hour: 2.83 m3 (747 gal), 5.4 min fill
    • 6 starts per hour: 4.71 m3 (1,245 gal), 9.0 min fill

    All three pass the fill-time check. At T = 4 min the formula reduces to gallons = gpm, hence 498 US gal. Alternating the two pumps each cycle halves each pump’s starts, so 1.885 m3 gives each about 7.5 starts per hour at worst-case inflow. Before fixing the volume, get the pump maker’s own starts limit and its curve at both the low-level duty point and the C = 140 case.

    Pump sewer system: when pressure sewers replace gravity

    In municipal engineering, a pump sewer system is a pressure sewer: a pump sewer replaces the deep gravity main with small-diameter pressure pipe fed by pump units on the connected properties (U.S. Environmental Protection Agency, 2002). In a house, the phrase can also mean a basement ejector, a sewage pump lifting the building’s sewage to the gravity sewer.

    Pressure-sewer grinder pump station at a house: a green basin lid in the lawn and an alarm panel on a post
    A pressure-sewer grinder pump station at one house: the basin lies under the green lid, and its control and alarm panel stands on a post.

    Grinder pump and STEP systems

    EPA’s pressure-sewer fact sheet (832-F-02-006, 2002) names two major types, septic tank effluent pump (STEP) and grinder pump (GP), and neither requires changes to the plumbing inside the house (U.S. Environmental Protection Agency, 2002). In a STEP system, wastewater enters a septic tank and the liquid effluent flows to a holding tank with a pump and controls (U.S. Environmental Protection Agency, 2002). With the solids left in the tank, that unit does the work of an effluent pump rather than a sewage pump (U.S. Environmental Protection Agency, 2002).

    In a GP system, sewage flows to a vault where a grinder pump grinds the solids and discharges into the pressurized pipe; GP needs no septic tank but may need more horsepower (U.S. Environmental Protection Agency, 2002). Grinding lets raw sewage travel through small pipe; a standard sewage pump passes solids whole (Rook, n.d.).

    EPA sizes centrifugal grinder pump systems with Q = 20 + 0.5D (Q in gpm, D the number of homes served) and no allowance for infiltration or inflow (U.S. Environmental Protection Agency, 2002). For 50 homes, Q = 20 + 0.5 x 50 = 45 gpm (2.8 L/s). No minimum velocity is generally used, but a GP system must reach 0.9-1.5 m/s (3-5 ft/s) at least once a day (U.S. Environmental Protection Agency, 2002). EPA suggests a Hazen-Williams C of 130-140, and mains are generally 50 mm (2 in) or larger PVC (SDR 21) (U.S. Environmental Protection Agency, 2002).

    Where a pressure sewer is the better choice

    Pressure sewers are most cost-effective, per EPA’s 2002 fact sheet, where housing density is low, where terrain undulates with relatively high relief, and where the outfall sits at or above the elevation of most of the service area (U.S. Environmental Protection Agency, 2002). Flat ground with high groundwater or bedrock qualifies too, where deep cuts or multiple lift stations would be too expensive (U.S. Environmental Protection Agency, 2002).

    Difficult construction or right-of-way conditions qualify as well (U.S. Environmental Protection Agency, 2002). The watertight, manhole-free design also eliminates extraneous flows (U.S. Environmental Protection Agency, 2002).

    The trade-off is operational. EPA’s listed disadvantages include much institutional involvement, operating and maintenance costs often above gravity’s (lift stations in a gravity sewer can reverse that), STEP tank pump-out every 2-3 years and a limited number of pumps per shared force main (U.S. Environmental Protection Agency, 2002). Without standby generators, power outages can cause overflows, and the usually septic wastewater brings odors and corrosion (U.S. Environmental Protection Agency, 2002). EPA estimates the mean time between service calls at 4 to 10 years for quality GP and STEP installations, though data vary greatly (U.S. Environmental Protection Agency, 2002).

    A single building below the sewer gets a sewage pump in a basin; a district matching EPA’s conditions should compare a pressure sewer with gravity on cost.

    Motors, seals and protection on a submersible unit

    The 2014 edition of the Recommended Standards for Wastewater Facilities (Ten States Standards), section 44.1, asks for submersible pumps and motors designed specifically for raw wastewater, including totally submerged operation during part of each cycle, and for an effective method to detect shaft seal failure or potential seal failure (Great Lakes-Upper Mississippi River Board, 2014).

    Submersible pump lifted from a wet well on its chain for service, cable coiled, a gloved hand steadying the motor housing
    A submersible pump lifted out on its chain for service, so no one has to enter the wet well.

    Section 44.2 of the same edition adds that submersible pumps be readily removable and replaceable without personnel entering or dewatering the wet well or disconnecting any piping in it (Great Lakes-Upper Mississippi River Board, 2014). Under any catalog name (submersible sewage pump, submersible waste pump), the motor must survive immersion and the operator must hear about a failing seal before the winding does.

    Seals and leak detection

    Goulds (Xylem) lists tandem mechanical seals in an oil-filled chamber, each operating independently (Xylem, 2025). Dual moisture-sensing probes in the oil between the inner and outer seals detect moisture before it reaches the bearings or stator (Xylem, 2025). Two automatic-reset thermostats sit on the windings (Xylem, 2025). KSB fits temperature and moisture sensors as standard on its Amarex KRT with cooling jacket. Shinjo’s JYWQ page lists a double-end mechanical seal running in an oil chamber.

    A second seal buys time. The probe turns that time into the warning the 2014 edition asks for. On any pump offered, ask where each sensor sits and what signal reaches the control panel.

    Cooling, IP68 and explosion protection

    Per Wilo, a surface-cooled motor sheds heat into the surrounding liquid and needs full submergence. KSB’s Amarex KRT with cooling jacket stays fully operational when not submerged, so it can run at low sump levels or installed dry; a closed water-glycol circuit cools the motor. Shinjo states the JYWQ’s internal circulation cooling system lets it work at the lowest pool level, with a working temperature up to 60 °C (140 °F). KSB also notes that the IEC standard behind IE efficiency classes is not binding for submersible motors.

    IP68 alone states no depth or duration. An IP rating has two digits: the first for protection against solids, the second for protection against liquids. In IEC 60529, numeral 8 means continuous immersion. As the test lab Applus+ Keystone quotes the standard, unless a product standard applies, the test conditions are agreed between manufacturer and user and must be more severe than IPX7. IPX7, as Element summarizes it, is immersion between 15 cm and 1 m (about 6 in and 3.3 ft) for up to 30 minutes. A datasheet claiming IP68 should declare both the depth and the duration.

    Where the wet well is a classified hazardous location, the pump motor has to suit that classification. Goulds’ 3SDX, for example, carries an explosion-proof motor rated Class 1, Division 1, Groups C and D (Xylem, 2025). The rating covers that listed model; the certificate should name the exact model offered.

    Materials

    Gray cast iron is the base material in both Goulds’ and KSB’s literature. Goulds specifies Class 30 gray cast iron (ASTM A48) for casing and impeller (Xylem, 2025); a KSB newsletter lists the Amarex KRT in gray cast iron, with duplex stainless steel (which KSB calls corrosion-resistant) or white cast iron (wear-resistant) as options. Neither label settles whether a material suits a particular sewage. Send the liquid temperature, pH and any industrial inflow, and ask the supplier to confirm the material.

    Why sewage pumps clog, air-lock and short-cycle

    The National Association of Clean Water Agencies (NACWA) estimated in September 2020 that wipes add about $441 million a year to the collection-system operating costs of US clean-water utilities, from 2019 data on 25 utilities in 19 states. Because it counts only those costs, NACWA calls the estimate conservative (National Association of Clean Water Agencies, 2020).

    UK Water Industry Research found that wet wipes contribute to 94% of UK sewer blockages, which cost water companies around £200 million a year to fix, DEFRA reported in 2025 (Department for Environment, Food & Rural Affairs, 2025). In functional performance tests reported in 2021 by Beck and colleagues, wastewater pumps reacted very differently to clogging: some lost hydraulic function, while in others performance stayed almost constant, or rose in some cases, but with an increased power requirement (Beck et al., 2021). A 2019 ASME conference paper by Mitchell and colleagues found that wipes labeled “flushable” differed in clogging effect depending on whether they met industry flushability guidelines (Mitchell et al., 2019). The fix for a sewage pump is upstream: keep wipes, “flushable” or not, out of the sewer.

    A Goulds (Xylem) presentation to the National Onsite Wastewater Recycling Association (NOWRA) on wastewater pump basics warns that, in a pump basin, a bottom-intake sewage pump can air-lock and not pump although its impeller turns (Rook, n.d.). The presentation calls for a 4.8 mm (3/16 in) relief hole in the discharge pipe inside the wet well, 51 mm (2 in) above the pump discharge and below the check valve (Rook, n.d.). Without a working check valve, backflow can spin the pump backwards (Rook, n.d.). On force mains, the 2014 edition of the Ten States Standards (section 49.2) calls for air relief valves at high points to prevent air locking (Great Lakes-Upper Mississippi River Board, 2014).

    Short cycling means too many starts, and Flygt’s design guidance ties starts per hour to pump life. The same Goulds presentation sets minimum run times of 1 minute for motors up to 1.1 kW (1-1/2 hp) and 2 minutes from 1.5 kW (2 hp) up (Rook, n.d.). More active volume between the start and stop levels, sized to the pump maker’s starts-per-hour limit, cures short cycling.

    Summit Pump’s 2020 newsletter states that most centrifugal pumps cannot pump liquids with more than 10% entrained air, and almost never much above 14%. Causes it lists include inflow dropping from height near the suction and shallow sumps with too little submergence, and the sump design has to avoid both.

    EPA’s 2000 lift-station fact sheet calls weekly inspections typical: pumps, motors and drives checked for unusual noise, vibration, heating and leakage, plus valves, control-panel switch positions, and discharge rates and pressures (U.S. Environmental Protection Agency, 2000). Log motor current as well, to catch a pump that clogs but keeps pumping.

    Buying a sewage pump: what the inquiry should state

    Suppliers quote the sewage pump they are asked for. When you compare sewage pumps for sale, send each bidder the same written list so the offers line up point for point.

    Item What to state Why it matters
    Duty point Flow at TDH at the low and the high wet-well level Static head differs between the levels
    Solids passage Largest sphere passed, in mm Outlet size is a different figure
    Installation Guide-rail wet pit, jacketed dry pit, self-priming or transfer duty Sets mounting and motor cooling
    Liquid Temperature and pH Limits materials and seals
    Power supply Voltage, phase, 50 or 60 Hz Motor and curve follow the supply
    Starts per hour Design figure for the controls The pump maker sets the limit (Great Lakes-Upper Mississippi River Board, 2014)
    Seals and sensors Seal arrangement, leak and temperature sensing Detects a leaking seal before water reaches the motor (Xylem, 2025)
    Cable and area Cable length; hazardous-area requirement Raw-sewage wet wells can be hazardous locations (Great Lakes-Upper Mississippi River Board, 2014)
    Materials Casing, impeller, shaft Corrosion and wear life
    Tests and documents Test standard and grade; curves and documents Makes the offer checkable

    The 2014 edition of the Recommended Standards for Wastewater Facilities (Ten States Standards), section 42.31, states all pumps should be tested by the manufacturer, including a hydrostatic test and an operating test (Great Lakes-Upper Mississippi River Board, 2014). An inquiry that names the hydraulic test standard and grade, such as ANSI/HI 14.6-2022 or ISO 9906:2012, turns that advice into a contract term.

    For a submersible, name both standards: the 2022 edition of the Hydraulic Institute’s ANSI/HI 11.6 covers only electrical and mechanical integrity testing, and hydraulic performance and hydrostatic pressure tests moved to ANSI/HI 14.6-2022. For a new wet well, ask that the intake follow ANSI/HI 9.8-2024.

    In Shinjo’s sewage pump range, the WQ specification table lists per model the impeller passage in mm beside outlet size, guide-rail fitting, maximum flow and head, speed and motor power. Its passages run from 20 mm on some 2 in outlet models to 80 mm on the 12 in outlet models. Compare offers on the passage figure, because outlet size does not tell you what solids a pump will pass.

    Frequently Asked Questions

    What is a sewage pump used for? It moves raw sewage and untreated wastewater, solids included. KSB names municipal treatment plants as the main use, plus buildings and private homes that cannot drain to the sewer by gravity (KSB, n.d.). Typical examples are a basement ejector serving fixtures below the sewer and the duty pumps in a municipal lift station.

    How much does a sewage pump cost? There is no single price; cost follows the specification. Drivers include size, solids passage, materials, motor power and voltage, seals and sensors, any hazardous-area rating, controls and testing. A lift station adds civil works, and EPA names design capacity and installed pump power as its most important construction-cost factors (U.S. Environmental Protection Agency, 2000).

    Will a sewage pump handle toilet paper? Yes. EPA’s septic-care rule of thumb is to flush nothing besides human waste and toilet paper (U.S. Environmental Protection Agency, n.d.). Wipes are the problem: nonwoven wipes do not disintegrate the way toilet paper does and can clog pumps (Mitchell et al., 2017), and UK government advice is to bin them, even those labeled flushable (Department for Environment, Food & Rural Affairs, 2025).

    Is a sewage pump the same as a septic system? No. A septic system treats and disperses wastewater on site; EPA describes a typical one as a septic tank, where solids settle as sludge, plus a drainfield that takes the liquid effluent (U.S. Environmental Protection Agency, 2026). The pump is a lifting device that may discharge into a septic tank or a sewer.

    Can you use a sump pump as a sewage pump? No. SSPMA classes, as Goulds presents them, rate sump pumps for clear water with solids up to 1/2 in (13 mm) (Rook, n.d.). The 2025 Plumbing Code of New York State, derived from the 2024 International Plumbing Code, requires pumps receiving toilet discharge to pass 2 in (51 mm) spheres (International Code Council & New York State Department of State, 2025).

    How do you know if your sewage pump is bad? Signs include a high-level alarm, a pump that runs continuously or will not start, and sewage odor. EPA’s typical weekly lift-station checks look for unusual noise, vibration, heating and leakage (U.S. Environmental Protection Agency, 2000). Watch motor current too: in functional performance tests, some clogging pumps kept almost constant head while needing more power (Beck et al., 2021).

    What is the difference between a sewage pump and a grinder pump? A grinder pump cuts solids before pumping them; a sewage pump passes them uncut. Cutting lets a grinder make a high-head discharge through small pipe, but it needs maintenance and overhauls (Rook, n.d.). Grinders serve one of the two major pressure-sewer types EPA describes, pumping into pressurized pipe (U.S. Environmental Protection Agency, 2002).

    What type of pump is used for sewage? A centrifugal pump designed not to clog. EPA states that centrifugal pumps are commonly used in lift stations (U.S. Environmental Protection Agency, 2000). The 2014 edition of the Ten States Standards (§42.33) asks raw-wastewater pumps to pass 80 mm (3 in) spheres (Great Lakes-Upper Mississippi River Board, 2014). Pressure sewers use grinder pumps or septic tank effluent pump (STEP) units (U.S. Environmental Protection Agency, 2002).

    Conclusion

    A sewage pump is defined by the solid it can pass, so fix that figure first. Flow and head come second, and they only make sense inside a station.

    That station is the system. Firm capacity carries peak hourly flow with any one pump out of service. Valves, level controls, alarms and wet-well ventilation keep it running and safe to service. Sizing runs from peak flow to total dynamic head to wet-well volume, using the pump maker’s own starts-per-hour limit. Where deep gravity cuts or extra lift stations cost too much, a pressure sewer can replace gravity pipe.

    Seal-leak detection and motor temperature sensors, plus a cooling jacket wherever the motor may run uncovered, keep a submersible alive. Wipes, not toilet paper, are what clog the pump.

    A datasheet should show solids passage in mm, the duty point at low and high wet-well levels, allowed starts per hour, the seal arrangement and the declared IP68 immersion conditions. A quote should show the pump count behind firm capacity and the edition of the standard the design follows.

    References

    1. Great Lakes-Upper Mississippi River Board of State and Provincial Public Health and Environmental Managers. (2014). Recommended standards for wastewater facilities (2014 ed.). Health Research, Inc., Health Education Services Division. https://www.health.state.mn.us/communities/environment/water/docs/tenstates/tenstatestan2014.pdf
    2. U.S. Environmental Protection Agency. (2000). Collection systems technology fact sheet: Sewers, lift station (EPA 832-F-00-073). https://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=901U0X00.TXT
    3. U.S. Environmental Protection Agency. (2002). Wastewater technology fact sheet: Sewers, pressure (EPA 832-F-02-006). https://www.epa.gov/sites/default/files/2015-06/documents/presewer.pdf
    4. U.S. Environmental Protection Agency. (2026, June 10). How septic systems work. https://www.epa.gov/septic/how-septic-systems-work
    5. U.S. Environmental Protection Agency. (n.d.). How to care for your septic system. https://www.epa.gov/septic/how-care-your-septic-system
    6. International Code Council & New York State Department of State. (2025). 2025 Plumbing Code of New York State. https://dos.ny.gov/system/files/documents/2025/07/2025pcnys_noa_2025-07-24.pdf
    7. Rook, J. (n.d.). Wastewater pumps: Basics, sizing, rules of thumb [Conference presentation]. National Onsite Wastewater Recycling Association. https://www.nowra.org/Customer-Content/www/CMS/files/24Mega_Rook_Pumps.pdf
    8. Xylem. (2025). Wastewater product catalog (WWS R20). https://www.xylem.com/siteassets/brand/goulds-water-technology/resources/brochure/wastewater-product-catalog-wws.pdf
    9. KSB SE & Co. KGaA. (n.d.). Sewage pump. In KSB centrifugal pump lexicon. https://www.ksb.com/en-global/centrifugal-pump-lexicon/article/sewage-pump-1117348
    10. National Association of Clean Water Agencies. (2020). The cost of wipes on America’s clean water utilities [Executive summary]. https://www.nacwa.org/docs/default-source/resources—public/executive-summary_cost_of_wipes.pdf
    11. Department for Environment, Food & Rural Affairs. (2025, November 18). New law bans plastic wet wipes to protect rivers and seas [Press release]. GOV.UK. https://www.gov.uk/government/news/new-law-bans-plastic-wet-wipes-to-protect-rivers-and-seas
    12. Beck, D., Holzbauer, Y., & Thamsen, P. U. (2021). Different clogging behavior of wastewater pumps. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting: Vol. 2. Fluid applications and systems; fluid measurement and instrumentation (Article V002T03A027). American Society of Mechanical Engineers. https://doi.org/10.1115/FEDSM2021-65422
    13. Mitchell, R.-L., Busche, S., & Thamsen, P. U. (2019). Investigations into wet wipe related clogging phenomena of wastewater pumps. In Proceedings of the ASME-JSME-KSME 2019 8th Joint Fluids Engineering Conference: Vol. 3B. Fluid applications and systems (Article V03BT03A038). American Society of Mechanical Engineers. https://doi.org/10.1115/AJKFluids2019-5446
    14. Mitchell, R.-L., Thamsen, P. U., Gunkel, M., & Waschnewski, J. (2017). Investigations into wastewater composition focusing on nonwoven wet wipes. Czasopismo Techniczne, 1, 125-135. https://doi.org/10.4467/2353737XCT.17.010.6107
    15. Guimarães, F. D., Oliveira, N. S., Vaz, M. M., & Formiga, K. T. M. (2026). Optimised operation of sewage pumping stations: A systematic review. Results in Engineering, 30, Article 110798. https://doi.org/10.1016/j.rineng.2026.110798

    Last reviewed and updated: October 2026. Author: Shinjo Pump engineering team. For pump selection support or a quotation on your duty point, contact our team.




  • Centrifugal Pump Maintenance: Wear Limits & Clearances

    Centrifugal Pump Maintenance: Wear Limits & Clearances

    • Oct 19, 2026
    • Hits: 46

    On this page

    Centrifugal pump maintenance that really extends pump life comes down to two habits: routine checks while the pump runs, and a precision rebuild when it is opened. In a rebuild, the wet end decides the result. New bearings and a new seal will not last if the impeller, casing and stuffing box cover go back with worn faces and open clearances. This guide follows Crane Engineering’s precision maintenance video and adds the routine checks, wear limits and fits you need to bring a pump back to as-new condition.

    Video: Precision Maintenance of a Centrifugal Pump

    Joe Frank of Crane Engineering inspects the wet end of a back pull-out end-suction pump. Video: Crane Engineering on YouTube (10:20).

    What the video covers:

    • 0:42 Casing inspection: face grooves, gasket area and cutwater
    • 1:32 Impeller inspection: vanes, back pump-out vanes and fits
    • 2:07 Stuffing box cover inspection
    • 3:00 Wear limits for reusing each part
    • 4:22 Impeller clearance, thrust and seal life
    • 6:43 Worn parts from real pumps
    • 8:32 An abrasive wear example
    • 9:22 Wear rings on split-case pumps

    Routine Centrifugal Pump Maintenance Checklist

    Most pump failures give warning first: noise, heat, leakage or vibration. Routine centrifugal pump maintenance catches them while the fix is still cheap. The schedule below draws on a widely used preventive maintenance guide for centrifugal pumps and on the U.S. Department of Energy’s pumping system tip sheets. Adapt the intervals to your duty, and follow your pump manual where it differs.

    Interval Check What to look for
    Daily Noise A gravel-like rattle at the suction usually means cavitation; a rising whine or rumble points to the bearings
    Daily Bearing temperature Feel or measure every bearing and compare with earlier readings, not just with a limit
    Daily Bearing oil and leaks Water or discoloration in the oil; oil leaking at gaskets
    Daily Seal and packing leakage Mechanical seal leakage within the maker’s limit; packing leakage typically 2–60 drops per minute
    Daily Seal flush and cooling Flush flow or flush line temperature; cooling water flowing through jackets and coolers
    Monthly Lubrication Top up oil, clean oiler bulbs and sight glasses, and check the oil level against the shaft centerline
    Monthly Guards and housekeeping Guards in place, debris cleared from the bearing bracket, drain holes open
    Every 6 months Standby pumps Turn the shaft by hand several turns to coat the bearings with oil; protect exposed machined surfaces from rust
    Yearly Alignment and coupling Check alignment with a dial indicator, allowing for thermal growth; inspect the coupling for wear and cracks; check the axial float
    Continuous trend Vibration and performance Rising vibration, or falling flow and head at the same speed, means wear inside the pump

    Do not keep tightening packing to stop a leak. Overtightened packing wears the shaft sleeve and raises power consumption. If it has to be tightened excessively, replace it.

    Why Worn Clearances Cost Efficiency and Reliability

    A centrifugal pump relies on small gaps between rotating and stationary parts to keep high-pressure liquid at the discharge from flowing back to the suction. As those gaps wear open, more liquid recirculates inside the pump. The pump keeps running, but it delivers less flow and head for the same power.

    The losses are significant. The U.S. Department of Energy notes that erosion of wear rings and the rotor can reduce a pump’s wire-to-water efficiency by 10% or more. In a worked example by pump engineer Lev Nelik, doubling the wear ring clearance on a double-suction pump rated at 8,000 gpm and 400 ft (about 1,800 m³/h at 122 m) lets about 4% of the rated flow leak back. At roughly 900 hp, that wastes about 27 kW, or around $23,600 a year at $0.10/kWh in continuous service.

    Energy is only part of the cost. As the video explains, open clearances also raise thrust loads and seal chamber pressure, which shortens bearing and seal life.

    Wet-End Inspection: What to Check on Each Part

    In a back pull-out end-suction pump, the wet end has three parts: the casing (volute), the impeller and the stuffing box cover, also called the seal chamber cover or back plate. When a back pull-out assembly is exchanged, the casing usually stays bolted into the piping, so it is easy to skip. Inspect it anyway: it is often the oldest part of the pump.

    Casing (volute)

    • Grooves across the face that runs next to the impeller.
    • Cracks, irregularities or washouts at the gasket surface.
    • The cutwater. It should be smooth and straight across; a worn or washed-out cutwater lets more liquid recirculate around the volute.

    Impeller

    • Grooves or general wear on the face that runs next to the casing.
    • Bent vanes.
    • The back pump-out vanes: their height and whether the edges are still sharp.
    • The threads, and the face that seats against the shaft sleeve.

    Stuffing box cover

    • Wear, grooves or pitting on the face that runs next to the impeller.
    • The gasket surface against the casing.
    • The bore where the shaft sleeve passes through.
    • The face where the mechanical seal mounts.
    • The register that locates the cover on the frame adapter.

    Wear Limits: When to Reuse and When to Replace

    The video gives clear limits for reusing wet-end parts on an end-suction pump. Lay a straight edge across each face to judge the depth of grooves and general wear.

    Part Area Replace when
    Casing Face next to the impeller Grooves or irregularities deeper than 1/8 in (3.2 mm)
    Impeller Face next to the casing Wear or grooves deeper than 1/16 in (1.6 mm)
    Impeller Vanes Any vane is bent
    Impeller Back pump-out vanes Worn by more than 1/32 in (0.8 mm), or edges rounded by abrasion
    Stuffing box cover Face next to the impeller Grooves or general wear of 1/8 in (3.2 mm) or more

    Where your pump manufacturer gives tighter limits, use those. A part just inside the limit can go back in, but expect some extra leakage and a small loss of efficiency. The video shows a stuffing box cover with grooves just under 1/8 in that falls into exactly this category, and a suction side plate with grooves deep enough that it should not be reused.

    Setting Open Impeller Clearance

    Open and semi-open impellers run with a small axial gap to the casing. For the mid-size ANSI pump in the video, the operating manual calls for 0.008 in (0.20 mm) at service temperatures of 200 °F (93 °C) or below. With the impeller set there, the gaps in front of and behind the impeller typically add up to 0.060–0.085 in (1.5–2.2 mm) between the casing and the stuffing box cover.

    The right setting depends on temperature. Parts grow as they heat up, so hot service needs a larger cold setting. One of the casings in the video came from a pump set at the standard 0.008 in while the process ran above 300 °F (about 150 °C). The impeller grew into the casing, the two rubbed, and the casing was heavily worn.

    On pumps that adjust with jack bolts and locking bolts on the bearing housing, the usual procedure is:

    1. Lock out the driver, then remove the coupling guard and the coupling.
    2. Mount a dial indicator with its button on the end of the shaft.
    3. Back out the jack bolts, then tighten the locking bolts evenly until the impeller just touches the casing. Zero the indicator.
    4. Back off the locking bolts, then tighten the jack bolts evenly to push the housing out until the indicator shows the specified clearance.
    5. Tighten the locking bolts evenly while the jack bolts hold the setting, and check that the shaft turns freely by hand.

    Some designs adjust with shims or an adjusting nut instead. Follow the manual for your pump. For more on the impeller types themselves, see open, semi-open and closed impellers.

    The Trap: Chasing Clearance Toward the Casing

    Because an open impeller is adjustable, it is tempting to keep moving it toward the casing as the faces wear. That restores the front clearance, but the impeller moves the same distance away from the stuffing box cover, and the back gap grows. The back pump-out vanes are designed to work across a small back gap, so a wider one causes trouble.

    What happens when the back gap opens up
    • Higher thrust. The back pump-out vanes lower the pressure behind the impeller and with it the axial thrust on the shaft. With a wide gap they lose effect, and very open clearances can lead to thrust bearing failures.
    • Solids reach the seal. The pump-out vanes no longer push particles outward, so more solids get into the seal area.
    • Higher stuffing box pressure. Packing leaks more heavily and mechanical seals fail sooner.

    Once the faces are worn past their limits, the fix is to restore or replace the parts, not to keep resetting the impeller.

    Wear Rings on Closed Impellers and Split-Case Pumps

    Closed impellers, including the double-suction impellers in split-case pumps, seal against the casing with wear rings rather than an axial gap. The video notes that on split-case pumps the total clearance between the impeller ring and the casing ring is typically only 0.020–0.040 in (0.5–1.0 mm), depending on pump size and ring material. Wear rings cannot be adjusted, so the only cure for wear is new rings.

    One fits-and-clearances checklist based on Hydraulic Institute standards gives this guide for the new diametral clearance between impeller ring and casing ring, for rings up to 12 in (305 mm) in diameter:

    Clearance = 0.010–0.012 in + 0.001 in per inch of ring diameter
    Example, 8 in (203 mm) ring: 0.018–0.020 in (0.46–0.51 mm)

    Add 0.005 in (0.13 mm) for materials that tend to gall, such as stainless steel.

    • When to renew them. The same checklist says to renew the rings when the clearance reaches twice the original value. Some manufacturers replace them sooner, when the clearance has grown by 40%.
    • Rear rings. Excessive clearance at the rear rings raises axial thrust and can damage the thrust bearing.
    • Fitting. Rings are pressed on with 0.002–0.003 in (0.05–0.08 mm) interference and locked with dowels or tack welds in at least two places. Do not bore out a casing ring seat by more than 3% of its original diameter.

    Fits and Clearances to Check on Reassembly

    A precision rebuild also restores the fits that keep the rotor running true. The values below come from the same checklist. Use the pump maker’s figures where they differ.

    Fit Inches Millimeters
    Ball bearing bore to shaft 0.0001–0.0007 interference 0.003–0.018 interference
    Ball bearing outside diameter to housing 0.0001–0.001 clearance 0.003–0.025 clearance
    Shaft sleeve to shaft 0.001–0.0015 clearance 0.025–0.038 clearance
    Impeller to shaft Metal to metal, up to 0.0005 clearance Metal to metal, up to 0.013 clearance
    Coupling hub to shaft Metal to metal, up to 0.0005 clearance Metal to metal, up to 0.013 clearance
    Throat bushing to shaft 0.015–0.020 clearance 0.38–0.51 clearance
    Seal gland throttle bushing to shaft 0.018–0.020 clearance 0.46–0.51 clearance
    Seal gland pilot to stuffing box 0.002–0.004 clearance 0.05–0.10 clearance
    Casing, cover and bearing housing alignment 0.004 maximum 0.10 maximum
    Mechanical seal faces Flat within 3 helium light bands About 0.0009

    Abrasive Wear: Reading the Damage

    The last end-suction example in the video is a back pull-out assembly from abrasive service, and every wet-end surface shows it. The vanes and the impeller face are worn and uneven. The back pump-out vanes are nearly gone. The stuffing box cover is cupped from the center outward, and the casing has heavy washout near the cutwater.

    In abrasive duty, plan for faster wear:

    • Shorten the inspection interval and trend performance, so parts are replaced before they pass their limits.
    • Keep the pump near its best efficiency point. At low flow, liquid recirculates inside the pump and wears it faster.
    • Choose harder materials, or a pump designed for solids, such as a slurry pump.
    • Protect the mechanical seal from solids with a suitable flush, and keep the back pump-out vanes in good condition.

    Centrifugal Pump Repair or Replacement?

    A rebuild makes sense when the casing is sound and the wet-end parts can be brought back within limits. Consider a new pump or a new back pull-out assembly instead when:

    • The casing is cracked, washed out at the gasket face or grooved beyond 1/8 in, and cannot be repaired by building up and re-machining.
    • The impeller has bent vanes or wear beyond the limits, and the parts would cost close to a new assembly.
    • The pump runs far from its best efficiency point. A pump that does not suit its duty will keep wearing the same way, so check the operating point on the pump performance curve and reselect if needed. Our guide on how to select a centrifugal pump covers the process.
    • Failures keep returning at short intervals even after careful rebuilds. Find the root cause first, whether it is the operating point, the piping or the liquid.

    If you are sourcing a replacement, see our comparison of centrifugal pump suppliers in China.

    Centrifugal Pumps Built for Easy Maintenance

    The pump layout decides how quickly and accurately centrifugal pump maintenance can be done.

    • IS horizontal clean water centrifugal pump. Built to ISO 2858 dimensions with a back pull-out layout: the casing and cover separate behind the impeller. Remove the coupling spacer and the rotor comes out without disturbing the casing, the suction and discharge piping or the motor. Flows up to 400 m³/h and heads up to 125 m, for clean water up to 80 °C.
    • IH stainless steel chemical centrifugal pump. The same back pull-out layout for corrosive liquids.
    • Horizontal split-case pump. The casing splits along the shaft line, so the upper half lifts off for access to the rotor and wear rings while the pipework stays connected.

    Shinjo supports its pumps with spare parts, remote technical support and video installation guidance.

    Planning a pump rebuild or a replacement? Send SHINJO the pump model, the duty and photos of the worn parts, and we will recommend spare parts or a replacement pump. See our full ranges of centrifugal pumps and split-case pumps.

    FAQ

    How often should a centrifugal pump be maintained?

    Check noise, bearing temperature and leakage daily, lubrication monthly, and alignment and the coupling once a year. Open the pump for a rebuild when trends show falling performance, rising vibration or repeated seal leaks, rather than on a fixed calendar.

    What is the correct impeller clearance for a centrifugal pump?

    Use the value in the pump’s operating manual for your service temperature. For example, the video quotes 0.008 in (0.20 mm) for a mid-size ANSI pump at 200 °F (93 °C) or below. Hot service needs a larger cold setting to allow for thermal growth.

    When should wear rings be replaced?

    A common rule is to renew them when the clearance reaches twice its original value. Some manufacturers replace them sooner, when the clearance has grown by 40%. Wear rings cannot be adjusted, so new rings are the only way to restore the clearance.

    Why does my mechanical seal keep failing after a pump rebuild?

    Check the back clearance. If the impeller was moved toward the casing to make up for front wear, the gap to the stuffing box cover grows. The back pump-out vanes then stop clearing solids from the seal area and the stuffing box pressure rises. Worn pump-out vanes have the same effect.

    Can a grooved impeller or casing be reused?

    Only within limits. In the video, casing grooves up to 1/8 in (3.2 mm) and impeller face wear up to 1/16 in (1.6 mm) are acceptable, while any bent vane means a new impeller. Parts close to the limit still work, but with some extra leakage and lower efficiency.

    How can I extend the life of a centrifugal pump?

    Run it near its best efficiency point, keep lubrication and alignment in order, and trend vibration and performance. When the pump is opened, rebuild it to as-new clearances instead of replacing only the bearings and the seal.




  • Double Diaphragm Pump Buyer’s Guide: Size, Build, Diaphragms

    Double Diaphragm Pump Buyer’s Guide: Size, Build, Diaphragms

    Double Diaphragm Pump Buyer’s Guide: Size, Build, Diaphragms

    • Oct 18, 2026
    • Hits: 40

    On this page

    Abstract

    A double diaphragm pump is bought once, and its diaphragms are bought for as long as it runs. Four choices decide what the pump costs to keep: port size against the real duty, the housing and its build, the diaphragm construction for the liquid, and the spares supply. The diaphragm flexes as the pump strokes and is the part a buyer keeps replacing, so its construction and supply belong in the specification. A quote that leaves these choices open leaves the buyer to settle them in service.

    Air-operated double diaphragm pump on a skid with its filter-regulator, gauge and flexible liquid hoses
    An air-operated double diaphragm pump on its skid: air enters through the filter-regulator, and liquid enters at the bottom manifold and leaves at the top.

    This guide is for procurement and project engineers who specify an industrial diaphragm pump and keep it running. They choose single or double design, port size, and the housing and valves. The diaphragm needs choices of its own: rubber, TPE or PTFE construction, and a replacement interval learned on the pump’s own duty. The purchase turns on air or electric drive, what the quote must state, and how to check the supplier behind it. Readers are assumed to know how the pump works and how to size its compressed-air supply.

    Key Takeaways

    • Port size is not the duty: All-Flo’s 25 mm (1 in) ball-valve pumps peak at 155.8-182 L/min (41-48 US gpm) (All-Flo, n.d.).
    • Size up one port size so the pump runs at fewer strokes per minute and lasts longer (Versamatic, n.d.).
    • Rubber, TPE and PTFE diaphragms trade flex life, chemical range and cost; none leads on all three (Caldwell, 2022).
    • Count strokes to set a replacement interval. No standard schedule exists (Dill, 2022); the pump’s own stroke history decides it.
    • Bolted pumps seal more easily for hazardous liquids; clamped pumps come apart with very few tools.
    • A double diaphragm pump quote should state materials by part, diaphragm grade, test standard and a spares list.

    Table of Contents

    What a double diaphragm pump is, and single vs double

    A double diaphragm pump is a positive displacement pump with two diaphragms on one shaft, each sealing its own liquid chamber (Yamada Pump, n.d.). While one diaphragm pushes liquid out of its chamber, the other draws liquid into the opposite chamber (Yamada Pump, n.d.). The drive is compressed air or an electric motor. The air-driven type falls under ANSI/HI 10.1-10.5, the Hydraulic Institute standard for positive displacement reciprocating pumps driven by compressed gas.

    Two chambers on one shaft

    Yamada describes two diaphragms on a common center shaft, “always evacuating one chamber while filling the other” (Yamada Pump, n.d.). Most standard pumps carry two diaphragms and four check balls, by Yamada’s account (Yamada Pump, n.d.).

    Versamatic defines the two counting units: “A stroke is one shift of the diaphragm assembly moving fluid out of one chamber. A cycle is two strokes” (Versamatic, n.d.). Flow equals strokes per minute times displacement per stroke (Versamatic, n.d.). By that definition, a double pump discharges on every stroke, twice per cycle. The flow still pulses rather than running steady: All-Flo’s pulsation dampeners fit at the pump’s discharge to reduce pressure and flow fluctuations (All-Flo, n.d.).

    Note: For the working principle, the air valve and a part-by-part walk-through, read our beginner’s guide to the diaphragm pump.

    Single diaphragm vs double diaphragm

    Both layouts exist, and they differ in how often liquid leaves the pump.

    The Hydraulic Institute’s pump FAQs set the two layouts side by side as duplex and simplex air-operated pumps. In a duplex pump, one air chamber pressurizes its diaphragm and pushes liquid out while the opposite chamber exhausts and liquid is drawn in. A simplex pump works the same way, except that no liquid is discharged during the diaphragm’s recharge stroke, which a spring return typically drives.

    A single diaphragm pump has one liquid chamber, which must refill before it can discharge again. A double pump discharges from one chamber while the other refills. In its guide to electric diaphragm pumps, Sandpiper notes that single diaphragm pumps are “typically used in applications requiring lower flow rates and pressures”.

    Other names for the same pump

    Double diaphragm pumps are also sold as dual diaphragm pumps. The air-driven type is the air-operated double diaphragm pump, or AODD pump. The motor-driven type is the electric double diaphragm pump, or EODD (Graco, n.d.). Graco gives “membrane pump” as another name for the diaphragm pump in general (Graco, n.d.).

    Metering pumps use the phrase differently: in Milton Roy’s double diaphragm metering pumps, two diaphragms work in tandem, and the maker notes that a double diaphragm does not automatically imply leak detection.

    Whatever the name on the quote, the specification starts with the duty: the liquid, the flow and the head the pump must meet. Port size comes after that, and it does not set the flow on its own.

    Sizing a 1″ diaphragm pump and every other port size

    Port size fixes the pipe connection and, through the housing behind it, a ceiling on flow. Makers publish that ceiling as a model’s maximum flow. A buyer reads those figures as limits and sizes a double diaphragm pump from its duty.

    Maximum flow by port size

    Ball-valve 1-inch (25 mm) double diaphragm pumps from All-Flo, Yamada and ARO carry maximum ratings of 155.8 to 182 L/min (41 to 48 US gpm), on water at maximum air pressure and open discharge (All-Flo, n.d.) (Yamada Pump, n.d.) (ARO, n.d.). Sandpiper rates its 1-inch HDF1 flap-valve pump to 265 L/min (70 US gpm) (Sandpiper, n.d.).

    Port size Maximum flow, US gpm Maximum flow, L/min Valve type note
    1/4 in (6 mm) 3.4-5.7 (Yamada Pump, n.d.) (All-Flo, n.d.) 12.9-21.6 Low: Yamada NDP-5; high: All-Flo A025 plastic
    3/8 in (10 mm) 6.0-9 (Yamada Pump, n.d.) (All-Flo, n.d.) 22.7-34 Low: Yamada DP-10; high: All-Flo C038
    1/2 in (13-15 mm) 8.0-17 (Yamada Pump, n.d.) (All-Flo, n.d.) 30.3-64.6 Low: Yamada DP-15; high: All-Flo A050 plastic
    3/4 in (19-20 mm) 15-31.7 (All-Flo, n.d.) (Yamada Pump, n.d.) 56.8-120.0 Low: All-Flo A075 metal; high: Yamada NDP-20
    1 in (25 mm) 41-48 (All-Flo, n.d.) 155.8-182 Ball valve: All-Flo, Yamada, ARO (Yamada Pump, n.d.) (ARO, n.d.). Sandpiper HDF1 flap valve at 265 L/min (70 US gpm) sits outside the range (Sandpiper, n.d.)
    1-1/2 in (38-40 mm) 90-130 (ARO, n.d.) (All-Flo, n.d.) 340-492 Low: ARO; high: All-Flo C150 plastic
    2 in (50-51 mm) 132-208 (ARO, n.d.) (Sandpiper, n.d.) 500-787 Low: ARO; high: Sandpiper HDF2 flap valve
    3 in (76-80 mm) 230-310 (ARO, n.d.) (Sandpiper, n.d.) 870-1,173 Low: ARO; high: Sandpiper HDF3 flap valve
    4 in (100-102 mm) 280-310 (ARO, n.d.) (Sandpiper, n.d.) 1,060-1,173 Low: ARO; high: Sandpiper HDF4 flap valve

    Each figure is one model’s maximum rating on water at maximum air pressure and open discharge; a range is the spread of several makers’ maxima at that port size, never an operating flow.

    Range chart of maximum flow by port size: 41-48 US gpm for a 1-inch ball-valve pump, 280-310 US gpm at 4 inches
    Maximum flow by port size from Yamada, All-Flo, ARO and Sandpiper ratings: each band spans several makers’ ceilings on water, never an operating flow.

    Why port size is not the duty

    A double diaphragm pump’s flow is strokes per minute multiplied by displacement per stroke (Versamatic, n.d.). Change either term and the flow moves with it. Diaphragm material changes the second: Yamada’s 2018 product guide lists the NDP-40’s discharge volume per cycle at 2.74 L (0.72 gal) with rubber diaphragms and 1.40 L (0.37 gal) with PTFE (Yamada America, 2018), roughly half the volume.

    Makers’ tables break the port-to-flow link too. All-Flo rates its 1/2-inch A050 and 3/4-inch A075 alike, at 56.8 L/min (15 US gpm) in metal and 64.6 L/min (17 US gpm) in plastic (All-Flo, n.d.), so the two ranges overlap. Sandpiper lists its 3-inch HDF3 and 4-inch HDF4 together at 1,173 L/min (310 US gpm) (Sandpiper, n.d.), the figure its HDF3 and HDF4 product page gives for the aluminum build. Shinjo lists its QBY3-25 and QBY3-25A, both DN25, at 57 and 151 L/min maximum flow (15.1 and 39.9 US gpm): one port size, two ratings.

    Head on the discharge line and a lower air supply both pull the operating point below these ratings. Reading that point off the curve and sizing the compressor are set out in Shinjo’s guide to AODD sizing and air use.

    Size up one port size

    Versamatic advises going up one pump size whenever possible. A pump kept away from its maximum capacity runs at fewer strokes per minute, which cuts air use and extends pump life (Versamatic, n.d.). Yamada’s version is shorter: “The longest running pumps are oversized and run slower” (Eklund, 2026). Yamada’s guidance on PTFE diaphragms adds that a larger pump running more slowly may deliver the flow in fewer cycles, which may improve diaphragm life.

    Sandpiper gives a worked example. A 1-inch (25 mm) double diaphragm pump can move 151 L/min (40 US gpm) of water against 3 m (10 ft) of head, but only near its maximum capacity and stroke rate. A pump one porting size up runs significantly slower, which extends pump life (Ellis, 2021). That duty sits just under 155.8 L/min, the rating of All-Flo’s plastic A100 and the lowest 1-inch ball-valve maximum of the three makers (All-Flo, n.d.).

    Versamatic and Sandpiper state the rule as one port-size step, and Yamada as oversizing. None of the three gives a percent-of-maximum figure, so ask any supplier who sizes a double diaphragm pump to a percentage for the source of that number.

    Industrial diaphragm pump construction choices

    Housing material, housing joints and valve type are the construction choices a buyer signs off on a double diaphragm pump. Each trades one property for another, such as chemical resistance against cost, or a tight seal against fast strip-down. Elastomer temperature limits and ball-valve particle sizes are explained in our pneumatic diaphragm pump guide.

    Housing material

    Versamatic rates the common housing materials for a double diaphragm pump in short, plain terms. A dash marks an attribute it does not rate.

    Material Strength and weight Chemical resistance Typical use or note
    Aluminum Strong, lighter Average (Caldwell, 2022) Popular in paint, oil, gas and mining
    Cast iron Very strong, heavy – Resists abrasion (Caldwell, 2022)
    Stainless steel – Excellent Food use (Caldwell, 2022)
    Alloy C – Very high Very costly (Caldwell, 2022)
    Polypropylene Light Strong for acids and caustics (Caldwell, 2022) Can be very affordable, depending on pump size
    PVDF Very strong plastic Higher than polypropylene Handles abrasion better than polypropylene (Caldwell, 2022)
    Conductive acetal – Much like polypropylene Prevents static discharge with flammable liquids (Caldwell, 2022)
    Bolted aluminum, bolted stainless steel and polypropylene diaphragm pumps side by side on a workbench
    Three housing materials on one bench: bolted aluminum, bolted stainless steel and polypropylene, each with its manifolds at top and bottom.

    Sandpiper lists conductive grades of polypropylene, acetal and PVDF among its plastic housing options (Ellis, 2021), so a flammable liquid does not tie a buyer to acetal alone.

    A housing rating describes a material family and says nothing final about a specific liquid. Check the actual liquid, at its concentration and temperature, against the maker’s compatibility guide for every wetted part. Graco’s materials guide advises testing a sample when compatibility is in doubt (Graco, 2024).

    Bolted or clamped

    Versamatic’s 2020 guidance on mining pumps describes clamped pumps as very simple to take apart with very few tools, with a manifold that can be removed on site, while bolted units take longer to strip down without pneumatic tools.

    A bolted double diaphragm pump seals more easily than a clamped one, and the same guidance stresses that advantage when the pumped fluid is hazardous. On its packaging-market page, Wilden says the bolted configuration “offers the highest level of product containment” and ensures even pressure on the sealing faces.

    Specify bolted for a hazardous liquid. Clamped earns its place where crews strip the pump on site often and the liquid allows it.

    Ball or flap valves, and the air valve

    Solids size decides the check-valve type. Yamada notes that most standard pumps carry four check balls (Yamada Pump, n.d.). Sandpiper builds its heavy-duty flap valve pumps for solids too large for ball valves; across the family’s port sizes, it rates them for solids of 25 to 76 mm (1 to 3 in) (Sandpiper, n.d.).

    On the air side, Yamada advertises a stall-free air valve (Yamada Pump, n.d.), and Graco advertises air valves that can be serviced externally (Graco, 2024). Both are manufacturer feature claims, so ask the supplier for the air-valve service procedure in the manual before counting either one in a comparison.

    Shinjo describes its cast-iron QBY3 double diaphragm pump as having “All-bolted construction with serviceable external air-valve assembly”. That pairs the sealing advantage of a bolted housing with an air valve reached from outside the pump.

    Housing, joints and valve type are chosen once, with the pump. The diaphragm is the part a double diaphragm pump owner keeps buying.

    Work with us

    The liquid and the duty decide the build. Our Diaphragm Pumps range is quoted against a stated duty point, so send the flow, discharge pressure, fluid and pumping temperature with your inquiry, together with the liquid’s character: solids, viscosity, abrasiveness and corrosiveness. With those on the page, the housing and diaphragm construction can be matched to the liquid rather than left open. View the Diaphragm Pumps range

    The diaphragm pump diaphragm: types, life and replacement

    Diaphragms are the primary wear components in an air-operated double diaphragm pump (Eklund, 2026), and because both sit on one shaft, the pump flexes both of them on every stroke. A 2023 review of symmetrical diaphragm pumps in the journal Symmetry names the diaphragm and the one-way valve as the components most susceptible to erosion and damage by the transported materials (Zhao et al., 2023). Construction and duty decide how often they are replaced.

    Rubber, TPE and PTFE pump diaphragms, the PTFE one with its backup, beside a used diaphragm with star-pattern cracks
    Diaphragms by construction: fabric-reinforced rubber, molded TPE, PTFE with its backup, and a used diaphragm with the star-pattern cracking that points to dry running.

    Rubber, TPE and PTFE constructions

    Diaphragms for a double diaphragm pump come in three material families (Zuckett, 2024): rubber, thermoplastic elastomer (TPE) and polytetrafluoroethylene (PTFE). One-piece designs join the diaphragm and its plate.

    Construction How it is made What it trades
    Rubber Synthetic rubber with a nylon fabric mesh (Zuckett, 2024) The greatest temperature spans, per Wilden
    TPE Injection-molded, no fabric reinforcement (Zuckett, 2024) Santoprene (a TPE) shares the best flex life with neoprene (a rubber), per Versamatic (Caldwell, 2022); Geolast flexes more than fabric-reinforced Buna-N at lower cost, per All-Flo
    PTFE with backup Non-elastic PTFE over a backup diaphragm of another material, such as neoprene or Saniflex (Hytrel) (Zuckett, 2024) Best chemical resistance in Versamatic’s list, but lower flex life and higher cost; abrasives in most cases rule it out (Caldwell, 2022)
    One-piece All-Flo single-piece, PTFE included, per the same All-Flo article; Wilden Chem-Fuse, no outer piston; Graco overmolded PTFE, no exposed plate (Graco, 2024) Chem-Fuse removes the outer-piston leak point, per Wilden; Graco rates overmolded PTFE at -10 to 82 °C (14 to 180 °F), standard PTFE at 4.4 to 100 °C (40 to 212 °F) (Graco, 2024)

    Wilden’s reduced-stroke PTFE diaphragm cuts stroke and displacement to limit abrasive contact with the housing. Graco claims “3x longer diaphragm life” for overmolded PTFE against standard diaphragms (Graco, 2024), and Wilden’s reliability page says Chem-Fuse extends diaphragm life “by up to 10-15x”; both are maker claims. Published limits disagree as well: Graco lists Hytrel to 65.6 °C (150 °F) (Graco, 2024) and Yamada to 120 °C (248 °F) (Yamada America, 2018), so check the quoted pump’s own documentation. Shinjo’s AODD guide tabulates elastomer temperatures. Converting between rubber or TPE and PTFE may need different center disks, shafts, backups, balls, seats and O-rings, per Yamada’s PTFE guidance. Shinjo lists NBR, neoprene, EPDM, PTFE and FEP diaphragms for its QBY3 double diaphragm pumps and states that the allowable medium temperature depends on the pump body material and the diaphragm material, so a plastic-bodied pump can be limited by its housing before its diaphragm.

    What shortens diaphragm life

    For a double diaphragm pump, Yamada states that component life “is strongly influenced by the number and severity of operating cycles” (Eklund, 2026). Too much air pressure makes the pump cycle very rapidly, which Versamatic links to extra wear and premature failure; the pressure should leave the liquid time to fully enter and leave each chamber (Dill, 2022). Yamada adds that excessive inlet pressure or excessive suction lift can shorten diaphragm life (Yamada America, 2018). Sandpiper notes that flexibility typically suffers at lower temperatures and that maximum flex life cannot be expected at a material’s temperature extremes (Ellis, 2021).

    Abrasives tear. Versamatic’s maintenance FAQs call paint an extremely abrasive fluid and expect a pump with neoprene or nitrile elastomers to break down within a relatively short time on it. All-Flo, announcing its All-Safe DRM leak sensor, calls diaphragm rupture rare and names large abrasives that tear the diaphragm as its most common cause. Hardware also loosens with creep and vibration; Sandpiper advises re-torquing to the manual with the pump not under pressure (Ellis, 2021).

    Reading a failed diaphragm

    A used diaphragm records how a double diaphragm pump was run. Versamatic’s troubleshooting guidance pairs patterns with likely causes:

    What the diaphragm shows Likely cause
    Discoloration, cracking or bubbling around the edge Excessive heat or chemical attack (Versamatic, n.d.)
    Wear marks on one side Excessive suction-side pressure or an imploded air side; keep below 0.7 bar (10 psi) of NPSH (Versamatic, n.d.)
    Star-pattern cracking Dry running (Versamatic, n.d.)
    Outer diaphragm plate imprint Over-torquing (Versamatic, n.d.)
    Punctures A sharp item entered the pump; fit a suction screen (Versamatic, n.d.)
    Scratch marks on the air side High fluid inlet pressure, most often flooded suction (Versamatic, n.d.)
    Stretched center hole Outer plate torqued incorrectly, or high inlet pressure overstretching the diaphragm (Versamatic, n.d.)

    Photograph each failed diaphragm and file it with the stroke count. The pattern shows whether to change the material or the way the pump is run.

    Detecting a rupture before the air side does

    On a double diaphragm pump, product at the air exhaust is the obvious sign of a failed diaphragm (Versamatic, n.d.). When a diaphragm fails, the liquid can reach the air side. Versamatic warns that an incompatible air side can then cause problems in the main and pilot air valves and in other systems on the same air line, so it advises air-side materials that also suit the liquid (Caldwell, 2022).

    Monitoring systems raise the alarm sooner:

    • Wilden’s Wil-Gard III places sensors between the PTFE primary diaphragm and the back-up diaphragm and reacts to conductive fluids, with a stated sensitivity of 75 microsiemens.
    • All-Flo’s All-Safe DRM puts an early-warning sensor between the PTFE overlay and the backup, plus a second sensor in the air section.
    • Yamada’s DM-2 can cut the air supply and can trigger a whistle or alarm when it detects a diaphragm leak.

    A conductivity sensor may miss a non-conductive solvent, so confirm the sensing principle suits the liquid.

    Setting a replacement interval

    Versamatic states that “there is no standard AODD pump maintenance schedule” (Dill, 2022). A stroke figure from another plant is a poor guide, since Yamada ties component life to the severity of operating cycles as well as their number (Eklund, 2026). The interval for a double diaphragm pump has to be learned on its own duty. Versamatic calls a stroke counter “a good way to keep track of approximately how many strokes you can expect before a diaphragm needs to be replaced” (Dill, 2022). Wilden’s PCMI cycle monitor counts complete cycles from a magnet on the air-valve spool. When a diaphragm or another part has to be replaced, Versamatic advises replacing all the components at the same time, while the pump is out of service (Versamatic, n.d.).

    Tip: Log the stroke count and failure pattern at every diaphragm change. Plan the next change below the shortest life seen on that duty, and re-baseline after any change of fluid, temperature, air pressure or diaphragm material.

    Wet kits and air kits

    Repair kits split a double diaphragm pump into a wet side and an air side. Wilden’s parts kit flyer says its Wet Kit “includes only elastomers located on the wet side of the pump such as diaphragms, balls, seats, gaskets and o-rings (if required)” and that no air-side parts are included. Its Air Kit includes the air-valve spool. Sandpiper offers its wear parts (diaphragms, balls, seats and flaps) in kit form, and individual wear parts on both the wet and air sides. A US distributor’s repair kit guide notes that a Wilden kit is coded to the pump configuration read from the model nameplate, and that a pump with integral piston diaphragms takes a different wet kit. Ask for kit part numbers that match the configuration quoted.

    Air-operated or electric double diaphragm pump

    The drive sets what a double diaphragm pump costs to run. Air-operated pumps run on plant compressed air; electric ones drive the same diaphragms from a motor.

    Electric double diaphragm pump with motor and gearbox on a plant floor, fed by a single power cable
    An electric double diaphragm pump: a motor and gearbox drive the diaphragms, and a power cable takes the place of the compressed-air line.
    Factor Air-operated Electric (motor-driven)
    Energy source Plant compressed air Site electrical supply
    Energy efficiency Low; runs on costly compressed air (U.S. Department of Energy, 2003) Higher, per Graco (Graco, n.d.)
    Hazardous areas No motor; ground it for flammable liquids (Caldwell, 2022) Explosion-proof motor for flammable liquids (Shinjo’s DBY instruction)
    Dry running Tolerated; sustained dry running wears the diaphragm and wastes air (Eklund, 2026) (U.S. Department of Energy, 2003) Model-specific
    Controls Regulator set to the maximum head required; flow control valve sets speed (U.S. Department of Energy, 2003) Motor matched to phase, voltage and frequency
    Initial vs running cost Can cost less to buy; typically more to maintain (Graco, n.d.) Lower lifetime cost, per Graco (Graco, n.d.)

    What compressed air costs

    The US Department of Energy’s 2003 compressed air sourcebook calls compressed air probably the most expensive form of energy in a plant, with a typical overall efficiency of 10 to 15 percent (U.S. Department of Energy, 2003). It lists diaphragm pumps among potentially inappropriate uses (U.S. Department of Energy, 2003) and notes they are commonly installed without regulators or with regulators set higher than necessary (U.S. Department of Energy, 2003).

    The efficiency figure covers compressed air systems in general, not one pump. At pump level, Versamatic writes that “operating AODD pumps costs more than purchasing them” (Dill, 2022), and its life-cycle cost article puts the purchase price at 5 to 20 percent of total cost of ownership. Shinjo’s AODD sizing and air-use guide converts air demand into kilowatts and running cost.

    When the electric version wins

    Graco claims its electric double diaphragm pump cuts energy consumption “up to 5x” against an air-operated one (Graco, n.d.), and that one of its electric pumps can reduce energy usage and costs “by up to 80%” (Graco, n.d.). A fivefold cut is an 80% saving, so the two figures are one vendor claim; “up to” marks the best case. Shinjo offers its DBY motor-driven pump where plant air is unavailable.

    Graco’s electric range covers 25 to 50 mm (1 to 2 in) ports, against 6 to 76 mm (1/4 to 3 in) for its air-operated pumps (Graco, 2024). The motor must match the site supply: ARO offers its three-chamber EVO 300 for 3-phase 50/60 Hz at 200-240 V, 380-500 V or 525-600 V. Shinjo requires an explosion-proof motor on the DBY for flammable liquids; that is an installation instruction, and the quote should still name the pump’s hazardous-area rating.

    Dry running is model-specific

    Air-operated pumps tolerate dry running because they use no close tolerances; Yamada calls the capability a feature, not an operating strategy (Eklund, 2026). Running empty, a pump “will rapid cycle, wearing out the diaphragm and wasting air”, per the US DOE sourcebook (U.S. Department of Energy, 2003).

    Electric double diaphragm pumps differ by model. Sandpiper’s electric pump guide says an EODD pump “can function safely even when the fluid source runs dry” and ARO’s electric pump overview lists run-dry capability, while Shinjo states its DBY is “strictly forbidden to run dry”. Ask the quote to state the dry-running limit for the exact double diaphragm pump offered.

    Running practices that decide diaphragm life

    Yamada states that the life of a double diaphragm pump’s components is strongly influenced by the number and severity of its operating cycles (Eklund, 2026), and its 2018 product guide adds that excessive inlet pressure or excessive suction lift can shorten diaphragm life (Yamada America, 2018). Air pressure, stroke rate and inlet conditions are set on site, after the pump is bought.

    • Set the air regulator to the duty. The US Department of Energy’s compressed-air sourcebook says “the regulator should be adjusted to equal the maximum head that the pump is required to provide” (U.S. Department of Energy, 2003). Check the setting again whenever the discharge line changes.
    • Fit speed control. On a double diaphragm pump, a flow control valve upstream of the regulator gives speed control, per the sourcebook (U.S. Department of Energy, 2003). Fewer strokes per minute mean fewer flex cycles.
    • Hold inlet pressure down. Versamatic advises keeping suction-side pressure below 0.7 bar (10 psi) of NPSH (Versamatic, n.d.). Measure inlet pressure on a flooded suction before start-up, and keep suction lift inside the datasheet figure.
    • Screen the suction. Versamatic traces diaphragm punctures to sharp items entering the pump and advises fitting a suction screen (Versamatic, n.d.). Clean it on a schedule; a clogged screen starves the inlet.
    • Limit dry running. An air-operated double diaphragm pump tolerates dry running because it uses no close tolerances, Yamada explains, yet a dry pump cycles faster, uses more air and adds diaphragm fatigue without moving liquid (Eklund, 2026). Versamatic warns that prolonged dry running weakens the diaphragm and recommends a pneumatic liquid level controller (Versamatic, n.d.); Verder’s guide to diaphragm pump failures describes a flow stop valve that cuts the air when air consumption rises.
    • Re-torque with the pump depressurized. Sandpiper notes that housing hardware loosens through material creep, vibration in transit and temperature changes, and advises re-torquing to the manual with the pump not under pressure (Ellis, 2021). Transit vibration makes installation the first check.
    • Match the air side to the liquid. A failed diaphragm can let liquid reach the air side, so Versamatic advises air-side materials that also suit the liquid (Caldwell, 2022).

    Pulsation dampeners and grounding belong to the same installation; Shinjo’s pneumatic diaphragm pump guide covers pulsation and static grounding for air-operated double diaphragm pumps.

    Reading a quote for a double diaphragm pump

    A quote records the pump a supplier will build. Before you compare a diaphragm pump for sale from two suppliers, check that both quotes answer the same duty questions and name the same parts.

    What the quote must state

    Graco and Yamada each publish the data they ask for before specifying a pump (Graco, 2024) (Yamada America, 2018). A complete quote for a double diaphragm pump restates the duty it was sized for and commits to the build:

    1. The liquid: solids, pH, viscosity, specific gravity, abrasiveness and corrosiveness.
    2. Pumping temperature, required flow rate and operating condition.
    3. Feed tank position, suction line length and vertical rise.
    4. Discharge distance and discharge pressure or total dynamic head.
    5. Hose diameters and other installation requirements.
    6. Available air supply; our AODD sizing guide lists the air-side fields.
    7. Materials by part: housings, diaphragms, check balls, seals and connecting rod.
    8. Certifications, production tests and whether a witnessed lab test is required.

    Sandpiper’s RFQ data sheet for its gas-operated G15 pump lists a 100% leak test of gas-containing housings, a hydrostatic test of pressure parts except the diaphragms at five times the maximum rated operating pressure, and static dissipation not exceeding 1 megaohm between the grounding connection and each metal component. A quote that only says “tested” cannot be checked.

    What drives the price

    Price for a double diaphragm pump follows the build: port size, housing material, diaphragm construction, valve type, drive (air or electric), accessories (pulsation dampener, leak detection) and the documents and tests ordered. Versamatic names PTFE and Viton the most expensive diaphragm materials (Caldwell, 2022), and Graco states that an air-operated pump can cost less to buy than an electric diaphragm pump (Graco, n.d.). Witnessed tests and material certificates are priced items too, so compare quotes line by line, never by the total.

    Interchangeable parts: ask, do not assume

    All-Flo states that its mounting feet and liquid porting location are “designed to match competitors’ footprint” (All-Flo, n.d.). That claim covers bolts and pipes only. Wet-end parts are a separate question. Even within one pump, Yamada’s PTFE guidance warns that converting between rubber or TPE and PTFE diaphragms can need different center disks, shafts, backup diaphragms, balls, seats and O-rings. Wilden’s kit flyer codes its repair kits by pump size, configuration, material and air distribution system.

    When a double diaphragm pump replaces an existing one, have the quote name the model and part numbers it claims to match, then check them against a dimensioned drawing.

    How to evaluate diaphragm pump suppliers

    Judge a supplier by the documents it can produce before the order: a factory that builds the double diaphragm pump holds them, and a reseller has to ask for them.

    Diaphragm pump on a supplier's test bench with suction and discharge gauges, a flow meter and a test record clipboard
    A pump on a performance test bench: gauges on the suction and discharge lines, a flow meter, and a clipboard to record each test point.

    Evidence that separates a maker from a trader

    A maker designs and tests the pump. An assembler builds it from bought-in major parts. A trader resells it. Ask for this evidence on the exact double diaphragm pump quoted:

    1. The supplier’s own performance curve and test record for that model.
    2. Material certificates for wetted parts, stating the EN 10204 type.
    3. A spare-parts list with part numbers, wet side and air side.
    4. A sectional drawing and a dimensioned drawing.
    5. An installation, operation and service manual.
    6. The number and issuer of any management-system certificate it names.

    Tests and material certificates

    ANSI/HI 10.6 Air-Operated Pump Tests, the Hydraulic Institute standard current in its 2021 edition, sets uniform procedures for mechanical integrity in operation, performance, NPSH/NPIP, suction lift, hydrostatic and noise testing of air-operated diaphragm and bellows pumps. Two makers’ double diaphragm pump curves tested to it can be compared on one basis.

    ANSI/HI 10.1-10.5, current in its 2021 edition, covers nomenclature, definitions, application and operation. When HI released the 2004 editions, it said the 10.6 tests are based on water at ambient temperature unless otherwise noted. Ask which test liquid and temperature the supplier’s curve used.

    Under EN 10204, each inspection document type certifies something different:

    EN 10204 type What the document is
    2.1 The manufacturer’s statement of compliance with the order
    2.2 Adds the results of non-specific inspection
    3.1 Reports the results of specific inspection; validated by the manufacturer’s authorized inspection representative, independent of the manufacturing department
    3.2 Validated by the manufacturer’s authorized inspection representative together with the purchaser’s authorized inspection representative or an inspector designated by official regulations

    Name the type in the order.

    Search IAF CertSearch’s ISO 9001 register by company, certificate number or certification body to see whether a certificate is active, suspended or withdrawn. The same page notes that ISO 9001 clause 8.4 requires control of external providers, so a certified organization must evaluate, select and monitor its suppliers. Ask a certified supplier how it does so.

    Spare parts for the life of the pump

    A double diaphragm pump needs new diaphragms for as long as it runs. A Pumps & Systems article on counterfeit AODD parts describes the warning signs: look-alike part numbers with an added prefix, missing manufacturing date stamps and parts shipped in unbranded bags. Fitting them can void the warranty, reduce flow, cause more breakdowns and compromise chemical compatibility. Buy diaphragms from a verified supplier or one the pump maker recommends (Zuckett, 2024). Before ordering, get in writing who will supply the pump’s diaphragm kits.

    Frequently Asked Questions

    What is a double diaphragm pump?

    A double diaphragm pump is a positive-displacement pump with two diaphragms on one shared shaft, so one chamber discharges while the other fills (Yamada Pump, n.d.). Compressed air drives the AODD version and an electric motor drives the EODD version (Graco, n.d.). The same machines are also sold as dual diaphragm pumps.

    What is the main difference between a single diaphragm pump and a double diaphragm pump?

    The double design has two chambers on one shaft and discharges on every stroke, two discharges per cycle (Versamatic, n.d.). The Hydraulic Institute describes both simplex and duplex air-operated pumps, and notes that a simplex pump discharges no liquid during its recharge stroke. Writing about electric pumps, Sandpiper says single diaphragm pumps typically serve lower flow rates and pressures.

    What are the disadvantages of a diaphragm pump?

    Air-operated models use compressed air: the US DOE calls it probably the most expensive form of energy in a plant (U.S. Department of Energy, 2003), at 10 to 15 percent typical overall efficiency (U.S. Department of Energy, 2003). A 2023 review in Symmetry names the diaphragm and one-way valve as the parts most susceptible to erosion and damage (Zhao et al., 2023). The flow also pulses, which is why Versamatic recommends a surge suppressor where steadier pressure is needed (Versamatic, n.d.).

    Can a double diaphragm pump run dry?

    Air-operated models tolerate dry running: they use no close tolerances and do not depend on the pumped liquid for lubrication or cooling (Eklund, 2026). Sustained dry running still wastes compressed air and adds diaphragm fatigue and wear on other internal parts, because the empty pump cycles faster (Eklund, 2026). Shinjo permits short-time dry running on its QBY3 but forbids it on its electric DBY.

    Do pump diaphragms need to be replaced?

    Yes. Versamatic states there is no standard AODD pump maintenance schedule and advises keeping notes on how each pump responds (Dill, 2022). A stroke counter tracks roughly how many strokes a diaphragm lasts before it needs replacing (Dill, 2022). When a part has to be replaced, Versamatic advises replacing all the components at the same time (Versamatic, n.d.).

    What is the maximum flow rate of a 1 inch diaphragm pump?

    Ball-valve 25 mm (1 in) models from All-Flo, Yamada and ARO top out at 155.8 to 182 L/min (41 to 48 US gpm), on water at maximum air pressure and open discharge (All-Flo, n.d.; ARO, n.d.; Yamada Pump, n.d.). Sandpiper rates its same-size flap-valve HDF1 to 265 L/min (70 US gpm) (Sandpiper, n.d.). These are ceilings, so size up one port size (Versamatic, n.d.).

    Are diaphragm pumps positive displacement?

    Yes. The Hydraulic Institute’s ANSI/HI 10.1-10.5 covers air-operated pumps as positive-displacement reciprocating pumps driven by compressed gas. Flow equals strokes per minute times the volume each stroke displaces (Versamatic, n.d.). That displacement changes with the diaphragm material: Yamada publishes separate rubber and PTFE performance curves (Yamada America, 2018).

    How much does a diaphragm pump cost?

    Price follows the specification: port size, housing and diaphragm materials, drive, and the tests and certificates ordered. Versamatic ranks PTFE and Viton the most expensive diaphragm materials (Caldwell, 2022). Graco says air-operated pumps can cost less to buy than electric ones (Graco, n.d.). Versamatic notes that operating an AODD pump costs more than buying it (Dill, 2022).

    Conclusion

    What a double diaphragm pump costs to keep, diaphragms included, is decided before the order is placed.

    Size for the duty. A catalog flow figure is one model’s maximum on water at maximum air pressure, so match the pump to the flow and head the process needs. Go up one port size: fewer strokes for the same volume mean fewer flex cycles on each diaphragm.

    Let the liquid choose the housing and the diaphragm. Rubber, TPE and PTFE each trade flex life against chemical range at a different cost; check the choice in a compatibility source. No universal replacement interval exists, so count strokes and read each failed diaphragm for its cause.

    Choose air or electric drive on what compressed air costs the plant and on the maker’s dry-running statement for that model. Hold the quote to materials by part, the diaphragm grade, the test standard and a spares list, and ask whether parts interchange. Judge the supplier on test reports and material certificates you can check.

    References

    1. Versamatic. (n.d.). The Versamatic AODD pump troubleshooting guide. Retrieved October 15, 2026, from https://www.versamatic.com/resources/aodd-pump-troubleshooting-guide-pillar-page
    2. Caldwell, T. (2022, February 1). Air-operated double-diaphragm (AODD) pump materials selection. Versamatic. https://www.versamatic.com/blog/aodd-pump-materials-what-to-use-and-why
    3. Dill, J. (2022, April 1). How AODD pump preventative maintenance helps you avoid failure. Versamatic. https://www.versamatic.com/blog/how-to-maintain-your-aodd-pump-to-avoid-failure
    4. Yamada Pump. (n.d.). Yamada diaphragm pump NDP series. Retrieved October 15, 2026, from https://www.yamadapump.com/products
    5. Yamada America. (2018). Yamada product guide [Product catalog]. https://www.yamadapump.com/assets/literature/guides/Yamada_2018_US-ENG_Product_Guide.pdf
    6. Eklund, R. (2026, September 1). Can an AODD pump run dry? Understanding the costs of dry running. Yamada Pump. https://www.yamadapump.com/blog/can-an-aodd-pump-run-dry-understanding-the-costs-of-dry-running
    7. All-Flo. (n.d.). Air operated double diaphragm pumps: Product catalog. PSG. Retrieved October 15, 2026, from https://www.psgdover.com/docs/default-source/all-flo-docs/brochures/all-flo-product-catalog.pdf?sfvrsn=16d2da38_16
    8. ARO. (n.d.). What is the maximum capacity of AODD pump? Ingersoll Rand. Retrieved October 15, 2026, from https://www.arozone.com/en/tools/blog/what-is-the-maximum-capacity-of-aodd-pump
    9. Sandpiper. (n.d.). Heavy duty flap pumps, metallic & non-metallic. Retrieved October 15, 2026, from https://www.sandpiperpump.com/pumps/heavy-duty-flap
    10. Ellis, T. (2021, June 4). The 5 most common AODD pumping mistakes and how to avoid them. Sandpiper. https://www.sandpiperpump.com/blog/most-common-aodd-pumping-mistakes
    11. Graco. (2024). Materials of construction guide (Form No. 345089, Rev. D). https://www.graco.com/content/dam/graco/com_documents/345/345089/345089EN-D.pdf
    12. Graco. (n.d.). How does a diaphragm pump work and what is it used for? Retrieved October 15, 2026, from https://www.graco.com/us/en/in-plant-manufacturing/solutions/articles/benefits-of-an-electric-diaphragm-pump.html
    13. U.S. Department of Energy. (2003). Improving compressed air system performance: A sourcebook for industry (2nd ed., DOE/GO-102003-1822). Compressed Air Challenge. https://www1.eere.energy.gov/manufacturing/tech_assistance/pdfs/compressed_air_sourcebook.pdf
    14. Zhao, K., Lou, Y., Peng, G., Liu, C., & Chang, H. (2023). A review of the development and research status of symmetrical diaphragm pumps. Symmetry, 15(11), Article 2091. https://doi.org/10.3390/sym15112091
    15. Zuckett, T. (2024, April 10). How to select the most efficient diaphragm for an AODD pump. Processing. https://www.processingmagazine.com/pumps-motors-drives/aodd-pumps/article/55016664/how-to-select-the-most-efficient-diaphragm-for-an-aodd-pump

    Last reviewed and updated: October 2026. Author: Shinjo Pump engineering team. For pump selection support or a quotation on your duty point, contact our team.




  • Multistage Pump Selection: Head, Stages, NPSH and Pressure

    Multistage Pump Selection: Head, Stages, NPSH and Pressure

    • Oct 11, 2026
    • Hits: 35

    On this page

    Multistage pump selection comes down to five numbers: the flow, the total head, the head each stage adds at that flow, the NPSH available at the first stage, and the highest pressure the casing will see. Divide the required head by the stage head to get the number of stages. Then check three things: the pump runs near its best efficiency point, the first stage will not cavitate, and suction pressure plus shut-off head stays within the casing rating. Shinjo’s DF multistage pump covers 15–336 m³/h and 144–690 m. For very small flows at high head, a partial emission pump is often the better fit.

    Step 1: Define the Flow Cases

    State the minimum, normal and maximum flow, and how long the pump runs at each. If two pumps share a header, work out the real combined demand rather than adding up the maximum of every user. Say whether a standby pump must carry the full duty alone.

    Record the liquid’s temperature, density, viscosity and vapor pressure as well. Water-based pump curves do not apply directly to viscous oils, and abrasive solids rule out most multistage pumps, which have close running clearances.

    Do not add a margin to every number. A safety factor on flow, another on friction losses and a third on head lead to a pump that spends its life throttled, far from its best efficiency point.

    Step 2: Calculate the Total Head

    For a pump moving liquid between two vessels, the required head is:

    H = Δz + Δp ÷ (ρ × g) + hL

    Δz is the elevation difference, Δp the pressure difference between the vessels, ρ the liquid density, g gravity and hL the friction loss in pipes, fittings, valves and equipment. For large tanks, the velocity difference is negligible.

    Example: water at 20 °C is pumped from an open tank to a vessel at 2.2 MPa gauge, 25 m higher, with 20 m of friction loss at 28 m³/h:

    H = 25 + 2,200,000 ÷ (998 × 9.81) + 20 ≈ 25 + 224.7 + 20 ≈ 270 m

    Two common mistakes: adding the discharge pressure again when it is already counted in Δp, and forgetting to subtract the pressure in a pressurized suction vessel. For more on the terms, see total head and total dynamic head and pump head loss.

    Step 3: Choose the Number of Stages

    In a multistage pump, the impellers work in series. The same flow passes through every stage, and their heads add up. So the number of stages is roughly the required head divided by the head of one stage at the duty flow.

    Shinjo’s DF46-50 adds 57.5 m per stage at 28 m³/h. For the 270 m example: 270 ÷ 57.5 = 4.7, so five stages are needed. The published data for this model at 28 m³/h:

    Stages Head at 28 m³/h Shaft power Motor
    3 172.5 m 24.8 kW 37 kW
    4 230 m 33.1 kW 55 kW
    5 287.5 m 41.4 kW 55 kW
    6 345 m 49.6 kW 75 kW

    Five stages give 287.5 m, which is 17.5 m more than needed. In practice, the pump will run slightly further out on its curve, where the system curve crosses it. Alternatively, the impellers can be trimmed, or a variable-frequency drive can reduce speed. Do not add a sixth stage “for margin”. It adds 57.5 m of head that would be burned off in a throttling valve, plus about 8 kW of shaft power.

    You can check the shaft power from the head, flow and efficiency (53% for this model):

    P = ρ × g × Q × H ÷ η = 998 × 9.81 × (28 ÷ 3,600) × 287.5 ÷ 0.53 ≈ 41.3 kW

    Select the motor for the highest power anywhere on the allowable operating range, not just at the duty point. Read the pump performance curve out to maximum flow and, for liquids heavier than water, scale the power with density.

    Step 4: Check NPSH at the First Stage

    Only the first impeller sees the suction conditions, so the first stage decides whether the pump cavitates. Adding stages raises the discharge pressure but does nothing for the suction.

    Manufacturers publish NPSH required as NPSH3: the suction head at which cavitation has already cut the first-stage head by 3%. The pump is cavitating at that point, so NPSH available must be higher, with a margin. Calculate NPSH available at the lowest liquid level, the highest temperature and the lowest suction vessel pressure together, using absolute pressures. Hot water is the usual problem. Its vapor pressure rises steeply, which is why feed pumps on deaerators sit far below the tank.

    If NPSH is short, raise the tank, enlarge and shorten the suction pipe, cool the liquid, choose a lower-speed pump, or add a low-head booster pump in front.

    Step 5: Check the Highest Pressure

    The casing must hold the highest pressure it can ever see. That is the maximum suction pressure plus the pump’s shut-off head, at maximum speed and maximum liquid density. It is not just the discharge pressure at the duty point. Compare it with the allowable working pressure of the casing, nozzles and seal at operating temperature. The hydrostatic test pressure, usually 1.5 times the allowable working pressure, is a factory test, not an operating limit.

    Check the inlet pressure as well. The DF pump is rated for an inlet pressure below 0.6 MPa. That matters when it takes suction from a pressurized vessel or runs in series behind another pump.

    Step 6: Plan for Thrust, Seals and Minimum Flow

    Every impeller pushes the rotor toward the suction end, and in a multistage pump these forces add up. Ring-section multistage pumps usually balance them with a balance disc or drum and a thrust bearing. Balance devices rely on close clearances, so abrasive particles wear them and let the rotor shift. Keep the liquid clean, and fit a suction strainer where needed.

    Ask the supplier what pressure the shaft seal sees. It depends on the design and is not always full discharge pressure.

    At low flow, most of the motor’s power turns into heat in a small amount of liquid, and the liquid recirculates inside the impellers. Ask for the minimum continuous flow. If the process can demand less, fit a minimum-flow bypass that returns liquid to the suction tank, not directly to the pump inlet.

    Red lines for multistage pumps
    • Never run dry. The balance device and wear rings have close clearances and seize without liquid.
    • Never run below minimum flow or against a closed discharge valve for long.
    • Do not exceed the inlet pressure rating, 0.6 MPa on the DF pump.
    • Fill and vent the pump before starting. Trapped air in the upper stages causes dry running.
    • Keep abrasive solids out. They wear the clearances that hold the rotor in place.

    Shinjo Multistage Pumps and Alternatives

    Pump Flow Head Construction and limits
    DF single-suction multistage 15–336 m³/h 144–690 m Cast iron, cast steel or stainless steel; −20 to 105 °C; inlet pressure below 0.6 MPa; 2,950 or 1,480 rpm
    Stainless steel multistage 0.3–10 m³/h 14.6–198 m Stainless steel casing, impeller and shaft; tungsten carbide bearings and seal
    Partial emission pump 0.1–15 m³/h 16–120 m Single stage, 0.75–37 kW

    For small clean-water duties of 2–32 m³/h, the compact cast iron multistage pump has stainless steel impellers and inner parts in a cast iron frame, with motors of 0.37–3 kW. It handles water from −15 to 70 °C, or up to 120 °C in its hot-water version.

    Choose the material from the liquid. Cast iron suits clean, cold water at moderate pressure. Cast steel suits higher pressures and hot water up to the DF’s 105 °C limit. Stainless steel suits corrosive liquids, demineralized water, which attacks cast iron, and hygienic duties.

    Very Low Flow at High Head: Consider a Partial Emission Pump

    A multistage pump sized for a very small flow ends up with small, inefficient stages, or with a larger pump running far below its best efficiency point and relying on a bypass. For flows up to 15 m³/h and heads up to 120 m, Shinjo’s high head partial emission pump reaches the head in a single stage. Its data table lists motor sizes for liquid densities of 1.0, 1.4 and 1.86, which shows how strongly power depends on density. Compare both options on curves, power and NPSH before deciding. For more on general selection, see how to select a centrifugal pump.

    What to Send with Your Enquiry

    • Minimum, normal and maximum flow, and the running time at each.
    • Total head, or the system details to calculate it: elevations, vessel pressures and pipe layout.
    • Liquid, temperature, density, viscosity and vapor pressure.
    • Suction conditions: tank level, suction pressure and NPSH available.
    • Maximum suction pressure, for the casing pressure check.
    • Material requirements, power supply and any required standard, such as API 610 or ISO 9906 test grades.

    Need a pump for a high-head duty? Send your duty data to SHINJO and we will select the stages, material and motor for you. See our full range of multistage pumps.

    FAQ

    Does adding stages increase the flow of a multistage pump?

    No. Stages in series add head while carrying the same flow. The operating flow is where the pump curve crosses the system curve, so more stages shift that point only because the head rises.

    How do I calculate the number of stages?

    Divide the required total head by the head of one stage at the duty flow, then round up. For example, 270 m at 28 m³/h with a DF46-50, which adds 57.5 m per stage, needs five stages. Then check efficiency, power and NPSH for that selection.

    Why does a multistage pump cavitate when it has so much head?

    Because cavitation happens at the first impeller, which sees only the suction conditions. Extra stages raise the discharge pressure, not the suction pressure. Improve NPSH available, or choose a pump with a lower NPSH requirement.

    What is the maximum inlet pressure of the DF multistage pump?

    The DF pump is rated for an inlet pressure below 0.6 MPa. Check this when it takes suction from a pressurized vessel or runs in series behind a booster pump.

    When is a partial emission pump better than a multistage pump?

    When the flow is very small compared with the head: up to about 15 m³/h at heads up to 120 m. A single-stage partial emission pump then avoids a multistage pump running far below its best efficiency point.




  • Non-Clogging Pump Selection for Solids, Fibers and Rags

    Non-Clogging Pump Selection for Solids, Fibers and Rags

    • Oct 11, 2026
    • Hits: 21

    On this page

    Choose a non-clogging pump around whatever is most likely to block it, not just around flow and head. Hard lumps need a free passage larger than the biggest lump. Long fibers and rags need an impeller they cannot wrap around, or a cutter that shreds them. Grit and sand rarely block a pump, but they wear it, so they call for harder materials. Shinjo’s non-clogging sludge pump passes particles of 15–80 mm and fibers of 150–1,000 mm, depending on size. For rags, ropes and plastic sheet, the submersible non-clogging pump with a shredder cuts them up before they reach the impeller.

    Identify What Will Block the Pump

    “Dirty water” is not a specification. Different solids block a pump in different ways, and each calls for a different design.

    Solid How it causes trouble What to look for
    Hard lumps: stones, scale, metal Wedge in the narrowest passage Free passage larger than the largest lump, in the pump and in every valve and fitting
    Long fibers: textile waste, hair Wrap around the impeller hub and vane edges A high fiber rating and a channel or vortex impeller
    Rags, wet wipes, plastic film Twist into ropes and mats on the vanes and inlet A cutter (shredder) pump, or screening upstream
    Grease and sticky sludge Build up in layers and narrow the passages Smooth passages, regular flushing, mixing in the pit
    Sand and grit Rarely block, but wear the impeller and casing Hard, wear-resistant materials and moderate velocity
    Sludge settled on the pit floor Reaches the pump as a thick slug at start-up A mixing device that keeps the solids suspended

    Look at the worst case, not the average. A batch discharge at the end of a shift, or the first flush after a rainstorm, can block a pump that handled weeks of normal flow.

    Impeller Types and Their Trade-Offs

    Impeller Best for Trade-off
    Single-channel (single vane) Large solids and fibers; widest free passage for its size Unbalanced hydraulic forces, so more vibration away from the design point
    Double-channel (two vanes) General sewage and larger flows Smaller passage than a single-channel impeller of the same size, but smoother running
    Vortex (recessed) Stringy, sludgy or gassy liquids; most solids never touch the impeller Lowest efficiency of the group
    Cutter or shredder Rags, ropes, cloth strips and plastic sheet Lower flow and head; cutters wear and cannot cut hard objects such as metal

    Most sewage pumps use single- or double-vane impellers with large channels. The JYWQ, for example, uses a double-channel non-clogging impeller. For a deeper look at impeller construction, see open, semi-open and closed impellers.

    Read the Solids Rating Correctly

    Free passage is the diameter of the largest sphere that can pass through the pump. It tells you about hard lumps, and nothing about fibers. A strip of cloth far thinner than the free passage can still catch on a vane edge and wrap.

    Fiber rating is the longest fiber the pump can pass. Across Shinjo’s non-clogging sludge pump range, particle tolerance runs from 15 to 80 mm and fiber tolerance from 150 to 1,000 mm. Both rise with pump size, so check the values for the model you select. The ZW self-priming non-clogging pump passes suspended solids up to 60% of its bore and fibers up to five times its bore. A DN100 ZW therefore passes solids of about 60 mm and fibers of about 500 mm.

    The whole route counts. A large pump passage is wasted if a check valve, reducer or strainer downstream is smaller. Oregon’s design rules for wastewater pump stations, for example, require raw sewage pumps to pass at least a 63 mm (2½ in) sphere and preferably 76 mm (3 in), and require the piping and valves to pass 76 mm.

    Shinjo Non-Clogging Pumps Compared

    Pump Construction Flow Head Solids handling
    Non-clogging sludge pump, iron or stainless steel Iron or stainless steel 8–300 m³/h 7–35 m Particles 15–80 mm, fibers 150–1,000 mm
    Stainless steel non-clogging sludge pump Stainless steel, oil-filled submersible motor 10–950 m³/h 7–35 m Large solids and fibers, motors up to 110 kW
    Submersible pump with shredder Submersible, with cutter 15–145 m³/h 4–25 m Cuts long fibers, plastic sheet, cloth strips and ropes
    ZW self-priming non-clogging Self-priming, installed above ground 8–800 m³/h Up to 70 m Solids up to 60% of bore, fibers up to 5 times bore
    JYWQ with mixer Submersible, with mixing device 10–600 m³/h 7–40 m Double-channel impeller; mixer stirs settled sludge

    Run the Pump at the Right Operating Point

    Many blockages blamed on the pump are caused by how it runs.

    • Stay near the best efficiency point. At low flow, liquid recirculates inside the pump, solids settle in the casing, and single-vane impellers vibrate. Calculate the total dynamic head at both high and low pit levels, and check both points on the pump performance curve.
    • Keep the velocity up in the discharge line. Slow flow lets solids settle in the pipe. Oregon’s rules call for 3.5–8 ft/s (about 1.1–2.4 m/s) in force mains. With a variable-frequency drive, they require at least 3.5 ft/s once in each pumping cycle and never less than 2 ft/s (0.6 m/s).
    • Do not slow a variable-speed pump too far. Below a certain speed, solids stop moving and the impeller loses its ability to shed fibers.
    • Do not oversize the motor to fight clogging. A bigger motor does not change the passage geometry. Size it for the full operating range of the curve.
    Common causes of clogging that are not the pump
    • A check valve or reducer smaller than the pump outlet. Solids pass the pump and jam downstream.
    • Long running at low flow, which lets solids settle and fibers collect.
    • A variable-speed drive set too slow to carry solids through the pipe.
    • A standby pump left standing in settled sludge. Alternate the duty and standby pumps.
    • Incoming flow dropping straight onto the pump inlet, which drives air and debris into it.

    Design the Pit to Prevent Blockages

    The wet well decides much of what the pump sees. Bring the incoming flow in away from the pump inlet, and avoid dead corners where solids collect. Slope the floor toward the pump. Where sludge settles, a mixer keeps it in suspension. The JYWQ has a built-in mixing device, with a stirring diameter of 1,200–3,000 mm, that turns settled sediment back into a slurry the pump can carry away.

    If rags are a constant problem and a cutter pump does not suit the duty, a screen upstream of the pit removes them. The screen then needs regular cleaning, or the blockage just moves upstream.

    Materials and Seals

    Choose materials for both corrosion and wear. On the ZW, cast iron suits liquids from pH 6 to 9 and stainless steel from pH 2 to 13. Abrasive grit needs hard wear surfaces and moderate speed. Where corrosion and abrasion occur together, as in many industrial effluents, the combined effect is worse than either alone.

    Shinjo’s non-clogging sludge pumps use two sets of hard-alloy mechanical seals. Hard faces matter in wastewater, because grit grinds away softer seal faces. Submersible versions run the seals in an oil chamber that protects the motor.

    What to Send with Your Enquiry

    • Flow, and the head at high and low pit levels.
    • Solids: largest lump, fiber length, rags or wipes, grit, and solids concentration.
    • A photo or sample of the worst material, if available.
    • Liquid temperature, pH and chemical content.
    • Pit dimensions and how the pump will be installed.
    • Discharge pipe size and length, including valves and reducers.

    Need a pump that will not block on your wastewater? Send a description of the solids to SHINJO and we will recommend a non-clogging pump and impeller. See our full range of sewage pumps.

    FAQ

    Can a non-clogging pump still clog?

    Yes. “Non-clogging” describes a design aim, not a guarantee. Oversized lumps, long rags, grease build-up, low-flow operation and undersized valves downstream can all stop a non-clogging pump.

    What size of solids can a non-clogging pump pass?

    It depends on the pump size and impeller. Shinjo’s non-clogging sludge pumps pass particles of 15–80 mm and fibers of 150–1,000 mm across the range. The ZW self-priming pump passes solids up to 60% of its bore.

    Is a vortex or a channel impeller better for fibrous wastewater?

    A vortex impeller keeps most solids away from the impeller and copes well with stringy material, but it is less efficient. A channel impeller is more efficient and passes large solids. For rags and plastic film, a cutter pump is often the most reliable answer.

    When should I choose a pump with a cutter?

    When the wastewater carries rags, wipes, ropes or plastic sheet, and the flow and head are within the cutter pump’s range: 15–145 m³/h and 4–25 m for Shinjo’s shredder model. Cutter pumps are not suited to hard objects such as metal or stones.

    Does a bigger motor prevent clogging?

    No. Extra power does not change the passage size or stop fibers from wrapping. Prevent clogging with the right impeller, free passage, operating point and pit design, and size the motor for the full operating range.




  • Self-Priming vs Submersible Sewage Pump: Which to Choose

    Self-Priming vs Submersible Sewage Pump: Which to Choose

    • Oct 11, 2026
    • Hits: 23

    On this page

    Choose a self-priming sewage pump when the lowest liquid level is within about 4.5 m of the pump and you want the pump and motor above ground, where they are easy to reach. Choose a submersible sewage pump when the pit is deeper, space is tight or the suction line would be long. There is also a middle option: a vertical submerged pump, with the pump in the liquid and the motor above the pit. In Shinjo’s range these are the ZW self-priming non-clogging sewage pump (8–800 m³/h), the WQ submersible sewage pump (10–6,000 m³/h) and the YW vertical submerged sewage pump (8–1,000 m³/h).

    Three Ways to Pump a Sewage Pit

      ZW self-priming WQ submersible YW vertical submerged
    Where it sits Beside the pit, above the liquid At the bottom of the pit, in the liquid Pump in the liquid, motor on a plate above the pit
    Suction lift Up to 4.5–5.5 m, with a suction pipe up to 10 m None None
    Flow 8–800 m³/h 10–6,000 m³/h 8–1,000 m³/h
    Head Up to 70 m 5–65 m 6–65 m
    Liquid temperature Up to 80 °C (200 °C on request) 0–55 °C 0–80 °C
    Maintenance access Pump and motor fully above ground Lifted out on guide rails Motor above ground; the pump is lifted out with its column
    Main risks Air leaks in the suction, loss of prime, too much lift Seal leakage into the motor, cable damage, low-level cooling Pit depth limited by the column length

    Start with the Suction Lift

    A self-priming pump does not pull liquid up. It lowers the pressure at its inlet, and atmospheric pressure pushes the liquid up the suction pipe. At sea level, atmospheric pressure equals about 10.3 m of water, and that is the theoretical limit. In practice, vapor pressure, friction in the suction pipe and the pump’s own NPSH requirement use up much of it. The ZW is rated for a self-priming height of 4.5–5.5 m with a suction pipe up to 10 m long.

    Two site conditions reduce the usable lift:

    • Altitude. At 1,000 m above sea level, atmospheric pressure is about 9.2 m of water, so you lose more than a meter compared with sea level.
    • Temperature. Warm wastewater has a higher vapor pressure and boils more easily at the low pressure inside the pump inlet.

    Check the lift with an NPSH calculation at the lowest liquid level and the highest liquid temperature. Example: a pump station at 500 m altitude, wastewater at 30 °C, the lowest level 4.0 m below the pump inlet, and 0.8 m of friction loss in the suction pipe:

    NPSHa = atmospheric head − vapor pressure head − static lift − suction losses
    NPSHa = 9.77 − 0.43 − 4.0 − 0.8 ≈ 4.5 m

    Oregon’s design rules for wastewater pump stations require a safety margin of at least 6 ft (1.8 m) above the pump’s NPSH required at suction-lift stations. In this example, the pump’s NPSH required at the duty point must therefore be no more than about 2.7 m. If it is higher, lower the pump, shorten the suction line or choose a submersible pump.

    How a Self-Priming Sewage Pump Works

    The ZW uses an external-mixing, axial back-flow design. Its casing holds a reserve of liquid. When the pump starts, the impeller mixes this liquid with the air in the suction pipe, separates the air in the casing, discharges it and returns the liquid to the impeller. After a few cycles, the suction pipe is full and the pump delivers normally. It needs no foot valve.

    The casing must be filled with liquid before the first start. After that it keeps its reserve between starts. Reliable priming depends on the installation:

    • Keep the suction pipe short, no longer than 10 m, and completely airtight. A small leak lets in air without dripping, so it is easy to miss.
    • Run the suction pipe so that it rises steadily to the pump, with no high points where air collects.
    • Fit a check valve in the discharge, and give the air a way out during priming.
    Red lines for self-priming sewage pumps
    • Never start the first time without filling the casing. Self-priming does not mean the pump can start dry.
    • No air leaks in the suction pipe. They are the most common cause of failed priming.
    • Do not exceed the rated lift after allowing for altitude and liquid temperature.
    • No suction pipe longer than 10 m. Longer pipes take too long to prime.

    What a Submersible Sewage Pump Needs

    A submersible pump avoids suction lift entirely, but it brings its own conditions.

    • Liquid temperature. The WQ is rated for liquids from 0 to 55 °C. For hotter industrial effluent, use the ZW or YW, which are rated to 80 °C.
    • Motor cooling. Most submersible motors are cooled by the surrounding liquid, so the stop level must keep the motor covered. Some designs, such as the JYWQ, have an internal cooling circuit and can run down to the lowest pit level.
    • Seals. A double mechanical seal in an oil chamber protects the motor. Where a moisture sensor is fitted in the oil chamber, it warns of seal wear before water reaches the windings.
    • Retrieval. Guide rails and an automatic discharge coupling let you lift the pump out without entering the pit. Plan the lifting gear and overhead clearance before ordering. Never lift the pump by its cable.
    • Hazardous gas. Sewage pits can contain flammable gas. A pump in the pit needs explosion-proof certification. A motor above the pit, as on the ZW and YW, avoids the problem.

    Which Pump for Which Site?

    Site condition Best choice
    Lowest level within about 4.5 m of the pump; frequent maintenance ZW self-priming
    Pit deeper than the self-priming lift, or a long suction line WQ submersible, or YW if the motor must stay dry
    Liquid above 55 °C ZW or YW, both rated to 80 °C
    Flow above 1,000 m³/h WQ, up to 6,000 m³/h
    Head above 65 m ZW, up to 70 m
    Sludge settles on the pit floor JYWQ, which has a mixing device that stirs sediment back into suspension
    Long fibers, rags and plastic strips A submersible pump with a cutter, such as the submersible non-clogging sludge pump

    Solids, Chemistry and Materials

    Whichever layout you choose, the impeller and passages must pass the solids in the wastewater. Oregon’s wastewater design rules, for example, require raw sewage pumps to pass at least a 63 mm (2½ in) sphere and preferably 76 mm (3 in), with piping and valves passing 76 mm. The ZW passes suspended solids up to 60% of the pump bore and fibers up to five times the bore. In a self-priming installation, also check the suction pipe, elbows and any strainer, because a blockage there stops the pump just as surely.

    Match the material to the chemistry. On the ZW, cast iron suits liquids from pH 6 to 9 and stainless steel from pH 2 to 13. The liquid density must not exceed 1,240 kg/m³. For more on the basics, see what a sewage pump is and how it works.

    Compare Running Cost at Real Operating Points

    The liquid level changes as the pit fills and empties, so the static head and the operating point change too. Calculate the total dynamic head at both high and low levels and compare pump curves across that range, not at one rated point. A submersible pump avoids suction losses. A self-priming pump costs less to maintain because nothing has to be lifted out of the pit. Include lifting equipment, civil works and the cost of an overflow when a pump is out of service, not just the purchase price.

    What to Send with Your Enquiry

    • Flow, and the head at high and low pit levels.
    • Pit depth, the lowest liquid level and the site altitude.
    • Liquid temperature, pH and chemical content.
    • Solids: maximum particle size, fibers, rags and grit.
    • Whether flammable gas may be present in the pit.
    • Power supply and control requirements.

    Deciding between a self-priming and a submersible pump? Send your pit layout to SHINJO and we will recommend the right sewage pump. See our full ranges of sewage pumps and self-priming pumps.

    FAQ

    How high can a self-priming sewage pump lift?

    The ZW is rated for a self-priming height of 4.5–5.5 m with a suction pipe up to 10 m long. The usable lift is lower at high altitude and with warm liquid, so confirm it with an NPSH calculation at the lowest pit level.

    Does a self-priming sewage pump need water before the first start?

    Yes. Fill the casing with liquid before the first start. The pump then keeps a reserve of liquid in the casing for later starts. Self-priming does not mean it can start or run dry.

    Can a submersible sewage pump handle hot wastewater?

    Only within its rating. The WQ is rated for liquids up to 55 °C. For hotter industrial effluent, use a pump with the motor out of the liquid, such as the ZW or YW, which are rated to 80 °C.

    Which is easier to maintain, a self-priming or a submersible pump?

    A self-priming pump, because the pump, seal and motor are above ground. A submersible pump has to be lifted out on its guide rails, which needs lifting equipment and clear access above the pit.

    Which pump is better for a deep pit?

    A submersible or vertical submerged pump. A self-priming pump cannot lift more than about 4.5–5.5 m, so a deeper pit would need the pump to be installed below ground, which loses its main advantage.




  • High Temperature Magnetic Drive Pump for 300–350 °C

    High Temperature Magnetic Drive Pump for 300–350 °C

    • Oct 11, 2026
    • Hits: 21

    On this page

    A high temperature magnetic drive pump for 300–350 °C liquids has to do three things the liquid makes difficult. It must keep its magnets cooler than the liquid, keep its internal bearings wet, and keep its pressure boundary within rating at temperature. Shinjo’s CQB-G is rated for liquids up to 300 °C and the MT-HTP for liquids up to 350 °C. Both cover 3.2–100 m³/h in stainless steel. Choose the rating from the hottest temperature the pump can see, then check NPSH, cold-start torque, cooling and warm-up. If a small seal leak is acceptable on hot thermal oil, a sealed hot oil pump is the simpler alternative.

    CQB-G or MT-HTP: Which Rating Do You Need?

      CQB-G MT-HTP
    Maximum liquid temperature 300 °C 350 °C
    Flow 3.2–100 m³/h 3.2–100 m³/h
    Head 20–80 m 15–80 m
    Sizes DN32–DN100 DN32–DN100
    Casing material Stainless steel 304, 316, 316L Stainless steel 304, 316, 316L
    Cooling design Multiple internal circulation paths, cooling vanes on the outer magnet rotor, pin coupling to the motor External circulation cooling system
    Motor range 1.5–55 kW 1.1–55 kW

    Choose the rating from the highest temperature the pump can reach, including upsets, not from the normal operating temperature. If the liquid normally runs at 290 °C but can reach 320 °C when a control loop fails, the duty needs the MT-HTP. Never assume a 300 °C pump will survive “short” excursions above its rating. The parts that set the limit, the magnets, bearings and gaskets, do not recover when the temperature falls.

    Why the Magnets Set the Limit

    The liquid temperature and the magnet temperature are not the same thing, and the magnets usually set the real limit. Typical operating ranges are 150–220 °C for high-temperature neodymium magnets and 250–350 °C for samarium-cobalt magnets. A coupling that pumps a 350 °C liquid therefore has to keep its magnets well below the liquid temperature.

    Heat reaches the magnets in three ways: by conduction through the casing, from the liquid circulating inside the pump, and from eddy currents in the metal containment shell, which add heat of their own. Overheated magnets lose torque. Above their limit, the loss becomes permanent, and the coupling slips under load.

    That is why the cooling design matters as much as the temperature rating. On the CQB-G, cooling vanes on the outer magnet rotor and several internal circulation paths carry heat away from the magnets. The MT-HTP uses an external circulation cooling system. In both cases, the cooling only works if air can reach the bearing frame and coupling housing. Do not cover them with insulation, even if the rest of the pump is insulated.

    Check NPSH at the Hottest Condition

    Vapor pressure rises steeply with temperature. Some heat transfer fluids are used above their atmospheric boiling point. For example, the common diphenyl/diphenyl oxide fluids boil at about 257 °C at atmospheric pressure. At 300 °C or more, such a system must be pressurized, usually through the expansion tank, or the liquid flashes at the pump suction.

    Calculate NPSH available at the highest temperature and the lowest system pressure, using absolute pressures and the vapor pressure of the actual fluid. Compare it with the pump’s NPSH required: 3.2–4.5 m across the CQB-G range. Then leave margin. A magnetic drive pump also needs liquid to stay liquid inside the pump, in the passages around the shell and bearings, where the eddy-current heat raises its temperature further. If it flashes there, the bearings run dry even though the pump still delivers flow.

    Size the Coupling for the Cold Start

    Thermal oils are many times more viscous cold than hot. At start-up the pump has to turn a thick liquid, so the torque demand can be far higher than at operating temperature. If the magnetic coupling is sized only for hot duty, it slips at a cold start. A slipping coupling heats its own magnets and can damage them before the system ever reaches temperature.

    Give the supplier the viscosity at the coldest start-up temperature as well as at operating temperature. The motor and the coupling must both handle the cold case. Alternatively, preheat the loop, or start at reduced speed through a variable-frequency drive until the oil thins.

    Warm Up and Cool Down Slowly

    Hot liquid hitting a cold pump, or cold liquid hitting a hot one, causes uneven expansion. The containment shell, the close-clearance silicon carbide bearings and the casing gaskets suffer most. Bring the pump up to temperature with the system, and do not flush a hot pump with cold liquid.

    Pressure Ratings Fall as Temperature Rises

    Metals lose strength when hot, so the allowable pressure of flanges, casings and containment shells falls as temperature rises. A Class 150 flange holds roughly half as much pressure at 300 °C as at ambient temperature. Work out the highest discharge pressure, which is suction pressure plus the pump’s shut-off head, and check it against the casing and shell rating at the maximum temperature, not at 20 °C.

    Piping loads also grow with temperature. Thermal expansion of the connected pipework can push the pump out of alignment or overload its nozzles. Support the pipes independently, and do not pull them into place with the flange bolts.

    Red lines for hot magnetic drive pumps
    • Never exceed the rated temperature, not even briefly. Magnet damage above the limit does not reverse.
    • Never run dry or against a closed valve. The bearings and the shell overheat within minutes.
    • Do not insulate the bearing frame or coupling housing. They need air to shed heat.
    • No cold start on thick oil unless the coupling is sized for it. Preheat, or start slowly.
    • No thermal shock. Warm up and cool down with the system.

    Sealless Pump or Sealed Hot Oil Pump?

    A magnetic drive pump is the right choice when no leakage is acceptable, as with toxic, flammable or valuable hot liquids. For hot thermal oil in a heating loop, where a small weep from a seal is acceptable and larger flows are needed, the LQRY thermal oil pump is simpler and covers a wider range.

      CQB-G / MT-HTP magnetic drive LQRY thermal oil pump
    Maximum liquid temperature 300 °C / 350 °C 350 °C
    Shaft sealing None (sealless) Shaft seal ring, mechanical seal or carbon seal
    Flow 3.2–100 m³/h 4.5–400 m³/h
    Maximum head 80 m 85 m
    Casing Stainless steel Cast steel
    Best for Toxic, flammable or valuable hot liquids Thermal oil heating loops and larger flows

    Both need a clean liquid. Aged thermal oil carries carbon and sludge, which wear the bearings of a magnetic drive pump. Filter the loop, and replace degraded oil before it damages the pump.

    What to Send with Your Enquiry

    • The liquid, its grade, and its vapor pressure and viscosity at both start-up and operating temperature.
    • Normal temperature, maximum temperature, and how long any upset lasts.
    • Flow, head and system pressure, including how the system is pressurized.
    • NPSH available at the hottest condition.
    • Ambient temperature and the cooling utilities available.
    • Start-up procedure, including whether the loop is preheated.
    • Hazardous-area classification.

    Pumping a hot liquid above 200 °C? Send the details to SHINJO and we will confirm the right high temperature model and coupling for your duty. See the full range of magnetic drive pumps, or read how to select a magnetic drive pump.

    FAQ

    Can a 300 °C magnetic drive pump handle short excursions to 350 °C?

    No. Magnets, bearings and gaskets can be damaged permanently above their rating, even briefly. If the liquid can reach 350 °C in any operating state, specify a pump rated for 350 °C, such as the MT-HTP.

    What magnets are used in high temperature magnetic drive pumps?

    Samarium-cobalt magnets are typically used at high temperature because they work at about 250–350 °C. Neodymium magnets are stronger but typically limited to about 150–220 °C even in high-temperature grades. The cooling design must still keep the magnets below the liquid temperature.

    Does a high temperature magnetic drive pump need cooling water?

    It depends on the design. The CQB-G cools itself through internal circulation paths and cooling vanes on the outer magnet rotor. The MT-HTP uses an external circulation cooling system. Ask which utilities the quoted model requires and what happens if they fail.

    Can a magnetic drive pump handle thermal oil?

    Yes, if the oil is clean and the pump is rated for its maximum temperature. Check NPSH at the hottest condition and size the coupling for cold-start viscosity. For large heating loops where a small seal leak is acceptable, a sealed thermal oil pump is often the simpler choice.

    Why does my hot magnetic drive pump decouple at start-up?

    Usually because the oil is too viscous when cold and the coupling torque is too low for that condition. Preheat the loop, start at reduced speed, or ask for a stronger coupling. Do not keep restarting a slipping pump, because each slip heats the magnets.




  • Magnetic Drive Pump vs Canned Motor Pump: Which to Choose

    Magnetic Drive Pump vs Canned Motor Pump: Which to Choose

    • Oct 11, 2026
    • Hits: 23

    On this page

    A magnetic drive pump and a canned motor pump both remove the shaft seal, the most common leak path in a centrifugal pump. The difference is how they drive the impeller. A magnetic drive pump uses a standard motor and turns the impeller through a magnetic coupling, across a sealed containment shell. A canned motor pump puts the motor rotor inside the liquid, behind a thin can that protects the stator windings. For most chemical transfer, a magnetic drive pump is easier to own because the motor is standard and the pump can be repaired on site. A canned motor pump is more compact and suits clean liquids in closed loops, but it usually needs specialist repair.

    How Each Design Removes the Shaft Seal

    Magnetic drive pump. An outer magnet rotor sits on the motor shaft. An inner magnet rotor is fixed to the impeller shaft. Between them is a stationary containment shell, also called an isolation sleeve, that closes off the liquid completely. The magnetic field passes through the shell and turns the impeller without any contact, so no shaft passes through the pressure boundary. The impeller runs on sleeve bearings lubricated by the pumped liquid.

    Canned motor pump. The pump and motor form one sealed unit on a common shaft. The motor rotor turns in the pumped liquid, and a thin corrosion-resistant liner, the “can”, separates the liquid from the stator windings. Some of the liquid circulates through the motor to cool it and to lubricate the sleeve bearings. There is no coupling and no separate motor.

    Both are sealless designs. Static joints such as casing gaskets and flanges remain, so “zero leakage” means no leakage at the shaft, not that the installation can never leak.

    Magnetic Drive vs Canned Motor: Side-by-Side

      Magnetic drive pump Canned motor pump
    Motor Standard motor, including off-the-shelf explosion-proof versions Special motor built into the pump
    Pressure barrier Stationary containment shell Stator can; in many designs the motor housing is a second barrier
    Heat added to the liquid Eddy-current heat from a metal shell; almost none from a plastic or ceramic shell Motor and can losses heat the liquid circulating through the motor
    Bearing monitoring Recommended Essential: worn bearings let the rotor touch the can and damage the windings
    Repair Motor swapped on site; wet end usually repaired on site Usually returned to the manufacturer or an approved shop
    Footprint Longer, because of the separate motor Compact, with no coupling; can be mounted in the pipeline
    Changing the duty Impeller or coupling can often be changed Tied more closely to the original design duty
    Standard API 685 covers both sealless designs API 685 covers both sealless designs

    Heat: The Hidden Load in Every Sealless Pump

    A metal containment shell sits in a rotating magnetic field, so eddy currents flow in it and turn into heat. That heat is carried away by the liquid flowing through the inside of the pump. Ceramic shell suppliers report that switching from a metal shell to a non-conductive one cuts power input by 10–15%. That figure gives an idea of the loss in a metal shell. Hastelloy is a common metal choice because its low electrical conductivity keeps the loss down.

    The heat matters most for liquids close to their boiling point. As an example, take a 15 kW pump on toluene. Here 10–15% is 1.5–2.3 kW. If only 1 m³/h of liquid circulates past the shell and bearings, the liquid there warms by about 4–5.5 °C:

    ΔT = P ÷ (ṁ × cp) = 1.5 kW ÷ (0.24 kg/s × 1.7 kJ/kg·K) ≈ 3.7 °C

    If that pushes the liquid above its boiling point at the local pressure, it flashes to vapor in the bearing passages and the bearings run dry. A canned motor pump has the same problem with motor heat. For volatile liquids, ask the supplier for the temperature rise in the internal circulation and the margin above vapor pressure.

    Dry Running, Solids and Gas

    Both designs depend on the pumped liquid to lubricate and cool their bearings. That gives them the same three weaknesses.

    • Dry running. Without liquid, the bearings overheat in minutes. A magnetic drive pump also loses cooling at the shell, and overheated magnets lose strength.
    • Solids. Abrasive particles wear the bearings and can block the small internal circulation passages. Sealless pumps need clean liquids.
    • Gas. Entrained gas or vapor breaks the liquid film in the bearings.

    The best protection is a motor power monitor, which detects dry running, a closed valve and a decoupled magnetic drive. A temperature sensor at the containment shell and a low-level or flow switch add further protection.

    Red lines for any sealless pump
    • Never run dry, not even for a short test. Fill and vent the casing before starting.
    • Never run against a closed discharge valve. The trapped liquid heats up quickly.
    • Keep above minimum flow so the internal circulation can carry the heat away.
    • Keep solids out. Fit a suction strainer where particles are possible, and keep it clean.

    Shinjo’s Sealless Pump Range

    Shinjo builds both types, but they serve different jobs.

    Pump Type Wetted material Flow Head Liquid temperature
    CQ Magnetic drive Stainless steel 304, 316, 316L Up to 60 m³/h 5–50 m Up to 80 °C, 200 °C on request
    CQB-F Magnetic drive Fluoroplastic lining 1.8–100 m³/h 8–32 m Up to 80 °C
    CQF Magnetic drive Polypropylene 1–25 m³/h 3–32 m Up to 60 °C
    ZCQ Self-priming magnetic drive Stainless steel 304, 316, 316L 3–60 m³/h 12–50 m Up to 80 °C
    ZBF Self-priming magnetic drive Polypropylene 6.5–12.5 m³/h 10–32 m Up to 80 °C
    CQB-G and MT-HTP High-temperature magnetic drive Stainless steel 304, 316, 316L 3.2–100 m³/h 15–80 m Up to 300 °C and 350 °C
    PBG Canned motor Cast iron 6.3–1080 m³/h 12.5–125 m Up to 90 °C, clean water

    The PBG canned motor pump is designed for clean water: HVAC circulation, booster sets, fire pressurization and hot and cold water loops. It mounts directly in a horizontal or vertical pipe. Because it never draws in air, it also suits vacuum systems. For corrosive, toxic or flammable chemicals, Shinjo supplies magnetic drive pumps, with the wetted material matched to the liquid.

    When to Choose Each

    Choose a magnetic drive pump when:

    • You want a standard or explosion-proof motor that your site can replace.
    • Maintenance will be done on site.
    • The liquid needs a lined or plastic wet end, such as acids and chlorides.
    • The duty may change later.
    • The pump must lift from below, which the self-priming ZCQ and ZBF can do.

    Choose a canned motor pump when:

    • The liquid is clean water or a similar clean liquid in a closed loop.
    • Space is tight or the pump has to sit in the pipeline.
    • Low noise matters, as in buildings.

    Choose neither when the liquid carries solids, the pump may run dry often, or the viscosity is high. In those cases, a sealed pump with a double mechanical seal or an air-operated diaphragm pump is more reliable. For sizing details on magnetic drive pumps, see how to select a magnetic drive pump.

    What to Send with Your Enquiry

    • The liquid, its concentration, density, viscosity and vapor pressure at operating temperature.
    • Normal and maximum temperature.
    • Flow, head and suction conditions, including whether the pump must self-prime.
    • Solids content, if any.
    • Hazardous-area classification and the motor protection required.
    • Whether secondary containment or leak detection is required.

    Comparing sealless options for a chemical duty? Send the details to SHINJO and we will recommend a magnetic drive pump with the right material and coupling. See the full range of magnetic drive pumps.

    FAQ

    Is a magnetic drive pump more efficient than a canned motor pump?

    It depends on the design. A metal containment shell can cost around 10–15% of input power in eddy-current losses, while a plastic or ceramic shell avoids most of that. Canned motors lose power in the can and the motor. Compare the absorbed power each supplier quotes at your duty point.

    Can a magnetic drive or canned motor pump run dry?

    No. Both rely on the pumped liquid to lubricate and cool their bearings, and dry running can destroy the bearings within minutes. Fit a power monitor or flow switch that stops the pump when it loses liquid.

    Which is better for hazardous chemicals?

    Both remove the shaft seal. A magnetic drive pump is easier to maintain because it uses a standard motor. A canned motor pump often provides a second containment barrier in the motor housing. Specify the containment and leak detection you need, and compare the offers against that.

    Does Shinjo supply canned motor pumps for chemicals?

    Shinjo’s PBG canned motor pump is a cast iron design for clean water up to 90 °C. For chemicals, we recommend a magnetic drive pump in stainless steel, fluoroplastic lining or polypropylene, depending on the liquid.

    What standard covers sealless pumps?

    API 685 covers sealless centrifugal pumps, both magnetic drive and canned motor, for petroleum, petrochemical and gas industry service. Many general chemical duties do not require it. If your project does, state it in the enquiry.




  • PTFE-Lined Pump vs Stainless Steel Pump: How to Choose

    PTFE-Lined Pump vs Stainless Steel Pump: How to Choose

    • Oct 11, 2026
    • Hits: 25

    On this page

    Choose a PTFE-lined pump when the liquid attacks stainless steel: hydrochloric acid, hydrofluoric acid, dilute sulfuric acid, aqua regia, mixed acids and strong oxidizers. Choose a stainless steel pump when the liquid stays within the resistance of the grade and the duty is hotter, higher in head or pressure, or carries solids. In Shinjo’s range, that means the IHF lined centrifugal pump (up to 80 °C and 87 m) or the sealless CQB-F on one side, and the IH stainless steel chemical pump (up to 150 °C, 132 m and 1.6 MPa) on the other.

    Which Pump for Which Liquid?

    Start with the liquid. For many common chemicals, one of the two options is ruled out before flow and head are even considered.

    Liquid Stainless steel pump PTFE-lined pump Usual choice
    Hydrochloric acid, any strength Not resistant: 304 and 316 are attacked at any concentration Resistant Lined
    Hydrofluoric acid Attacked Resistant Lined
    Sulfuric acid, 5–80% Attacked; 316 is only usable below about 5% or above 95% at low temperature Resistant Lined
    Nitric acid 304L and 316L are widely used Resistant Either; stainless steel for higher temperature or head
    Sodium hydroxide Suitable at moderate temperature Resistant Either
    Brine and seawater 316L is limited to about 1,000 ppm chloride Resistant Lined, or duplex steel for high head or solids
    Organic solvents and oils Usually suitable Usually resistant, but some solvents permeate fluoroplastics Stainless steel
    Liquids with hard or abrasive solids Suitable grades tolerate moderate solids Hard particles cut the lining Stainless or duplex steel
    Any liquid above 80 °C IH pump is rated to 150 °C Above the published rating Stainless steel or alloy

    For 98% sulfuric acid, where cast iron is also an option, see our guide to the concentrated sulfuric acid pump.

    What “PTFE-Lined” Means in a Pump

    In the pump trade, “PTFE-lined” and “Teflon-lined” usually mean any fluoroplastic lining: PTFE, FEP (also called F46) or PFA. PTFE cannot be melt-processed, so molded pump linings are usually FEP or PFA, which flow when heated. The IHF is lined with FEP. Its impeller and pump cover are metal inserts with fluoroplastic sintered over them.

    The metal casing carries the pressure and the pipe loads, and the lining resists the chemicals. This is why a lined pump can handle hydrochloric acid, hydrofluoric acid, aqua regia, strong alkalis, strong oxidizers and most organic solvents. These are all listed on the IHF product page. Doing the same with solid metal would mean a far more expensive nickel alloy casing.

    The fluoroplastics themselves tolerate high temperatures: PFA is rated for continuous service up to 260 °C. The pump’s limit is much lower because the lining is locked into a steel casing, and plastic expands many times more than steel when heated. Heat and rapid temperature changes stress the bond between the two. That is why the published liquid temperature for the IHF and CQB-F is 80 °C.

    The IHF uses an external bellows mechanical seal, so the springs and metal parts of the seal sit outside the liquid. The stationary face is 99.9% alumina ceramic or silicon carbide, and the rotating face is filled PTFE or silicon carbide.

    Where Stainless Steel Pumps Fail

    Stainless steel resists corrosion because of a thin chromium oxide film. Anything that breaks that film down faster than it can reform will corrode the pump, and some chemicals do this from the first day.

    • Hydrochloric acid. Standard 304 and 316 are considered non-resistant at any concentration and temperature.
    • Chlorides. A widely used guideline for immersed stainless steel puts the chloride limit at about 200 ppm for 304L, 1,000 ppm for 316L and 3,600 ppm for duplex 2205. Above that, pitting and crevice corrosion start. Crevices, deposits and heat lower these limits.
    • Hot chlorides. Chloride stress corrosion cracking of 304 and 316 is rare below 60 °C but becomes a real risk above it. Duplex grades resist it much better.
    • Dilute reducing acids. Sulfuric acid between about 5% and 80% attacks 316 actively.

    The grade matters as much as the word “stainless”. The IH pump and the CQ magnetic drive pump are offered in 304, 316 and 316L. For flue gas desulfurization slurry, which combines chlorides, acidity and abrasion, the cast steel desulfurization pump uses a duplex (“two-phase”) alloy for the casing and impeller.

    Where PTFE Linings Fail

    A lining resists chemicals well. It fails mechanically and thermally, and these failures usually come from operating conditions rather than from the chemical itself.

    • Heat and thermal cycling. Running near the top of the range, or heating and cooling the pump quickly, can blister the lining or separate it from the casing. Steam cleaning is a common cause, because steam is well above 80 °C.
    • Vacuum. If the suction can fall below atmospheric pressure, for example when a line drains or siphons, the lining can be pulled away from the casing. Tell the supplier if vacuum is possible.
    • Solids and cavitation. Hard or sharp particles cut and wear the lining, and collapsing cavitation bubbles erode it. Once the metal behind it is exposed, it corrodes quickly.
    • Permeation. Small molecules such as hydrogen chloride, chlorine and bromine slowly diffuse through fluoroplastics. They can condense behind the lining and cause blisters. A thicker lining slows this down.
    • Mechanical damage. Pipe strain, overtightened flanges and careless tools during maintenance all crack linings.

    Lined pumps also reach lower heads. The IHF goes up to 87 m and the CQB-F up to 32 m, while the IH stainless steel pump reaches 132 m.

    Five things that destroy a lined pump
    • Steam-out or hot cleaning above the 80 °C rating.
    • Vacuum in the suction when the system drains or siphons.
    • Hard solids or cavitation that cut through the lining.
    • Dry running, especially in a lined magnetic drive pump whose bearings are cooled by the liquid.
    • Sudden temperature changes such as hot acid entering a cold pump.

    Shinjo Lined and Stainless Steel Pumps Compared

    Pump Construction Flow Head Liquid temperature Shaft sealing
    IHF Metal casing lined with FEP 3–130 m³/h 5–87 m Up to 80 °C External bellows mechanical seal
    CQB-F Metal casing with fluoroplastic lining, magnetic drive 1.8–100 m³/h 8–32 m Up to 80 °C None (sealless)
    IH Stainless steel, back pull-out design 3.2–400 m³/h 5–132 m −20 to 150 °C Mechanical seal
    CQ Stainless steel 304, 316 or 316L, magnetic drive Up to 60 m³/h 5–50 m Up to 80 °C, 200 °C on request None (sealless)

    The IH has a back pull-out design. The rotating assembly comes out after removing the coupling spacer, without disturbing the casing, piping or motor. That shortens maintenance on a pump that sees regular seal changes.

    Sealed or Sealless?

    The casing material is only half the decision. If a leak would be dangerous, toxic or costly, choose a magnetic drive pump with no shaft seal: the CQB-F for liquids that need a lining, or the CQ for liquids stainless steel can handle. For cool, mildly corrosive liquids, the CQF polypropylene magnetic drive pump is a lower-cost option up to 60 °C.

    Magnetic drive pumps have their own limits. Their internal bearings are lubricated by the pumped liquid, so they must never run dry, and they need a clean liquid. For more on sizing them, see how to select a magnetic drive pump.

    Compare the Cost Over the Pump’s Life

    For hydrochloric acid, the real comparison is not lined pump against 316, because 316 fails. It is lined pump against a nickel alloy such as Hastelloy, and the lined pump is usually much cheaper. For a liquid that stainless steel handles well, a stainless pump avoids every lining risk above and tolerates upsets, solids and hot cleaning. In that case, the lining adds cost without adding life.

    Count the failures, not just the purchase price. A lined pump that blisters after every steam-out costs more than a stainless pump in the right grade. A 316 pump that pits through in brine costs more than a lined pump that would have lasted.

    What to Send with Your Enquiry

    • The liquid and its concentration range, including trace chlorides or fluorides.
    • Normal and maximum temperature, and any steam or hot-water cleaning.
    • Flow, head and suction conditions, including whether vacuum is possible.
    • Solids content, particle size and hardness.
    • Whether a leak is acceptable, which decides between a sealed and a sealless pump.
    • Operating pattern: continuous, batch or frequent starts.

    Not sure whether your liquid needs a lining? Send the details to SHINJO and we will recommend a pump and material for your duty. Our full range is in the chemical process pumps category.

    FAQ

    Is a PTFE-lined pump the same as a Teflon-lined pump?

    Yes. Teflon is a brand name for PTFE and related fluoroplastics. In practice, “PTFE-lined” and “Teflon-lined” pumps are often lined with FEP or PFA, which can be molded. The IHF is lined with FEP (F46).

    Can a PTFE-lined pump handle hydrochloric acid?

    Yes. Fluoroplastic linings resist hydrochloric acid at all concentrations within the pump’s temperature rating, while 304 and 316 stainless steel do not. Over time, hydrogen chloride can permeate the lining, so avoid running at the top of the temperature range.

    Why is a lined pump limited to 80 °C if PTFE can handle 260 °C?

    The limit protects the bond between the lining and the steel casing. Plastic expands many times more than steel, so heat and rapid temperature changes can blister or loosen the lining long before the plastic itself degrades.

    Is 316L stainless steel good enough for seawater?

    Usually not. A common guideline limits 316L to about 1,000 ppm chloride, and seawater contains about 19,000 ppm. Use a lined pump, a duplex or super duplex steel, or a plastic pump for seawater and strong brines.

    Can a PTFE-lined pump handle slurry?

    Only fine, soft solids in low concentration. Hard or sharp particles cut and wear the lining. For corrosive slurries, a duplex steel pump such as the desulfurization pump is usually the better choice.